Light Path Diagnostics; Lenovo Xclarity Provisioning Manager - Lenovo ThinkSystem SR650 Product Manual

Hide thumbs Also See for ThinkSystem SR650:
Table of Contents

Advertisement

The XClarity Controller provides remote server management through industry-standard interfaces:
Intelligent Platform Management Interface (IPMI) Version 2.0
Simple Network Management Protocol (SNMP) Version 3
Common Information Model (CIM)
Data Center Manageability Interface (DCMI) Version 1.5
Redfish REpresentational State Transfer (REST) API
Web browser with HTML5 support
Command-line interface
Virtual Operator Panel with XClarity Mobile App via the front USB port with XClarity Controller access
Virtual Operator Panel provides quick access to system status, firmware, network, health, and alerts information.
With proper authentication, it also allows to configure systems management and network settings and to control
system power (Power on, Power off, Restart). The Virtual Operator Panel can be accessed from the XClarity Mobile
App running on the Android or iOS mobile device that is connected to the front USB port with XClarity Controller
access (See
Components and
Note: Depending on the system settings, the front USB port can be assigned to XClarity Controller for
management functions, or to the system as a regular USB 2.0 port, or switched between two functions by using
the system ID button.
The following table lists the XClarity Controller FoD upgrades.
Table 45. XClarity Controller FoD upgrades
Description
ThinkSystem XClarity Controller Standard to Advanced Upgrade
ThinkSystem XClarity Controller Standard to Enterprise Upgrade
ThinkSystem XClarity Controller Advanced to Enterprise Upgrade
* Factory-installed only.
** Field upgrade only.
Configuration notes:
For factory-installed upgrades, either Standard to Advanced Upgrade (feature AVUT) or Standard to
Enterprise Upgrade (feature AUPW) can be selected, but not both.
For field upgrades, the Advanced to Enterprise Upgrade (4L47A09133) requires the Standard to Advanced
Upgrade to be activated on the server previously with either the factory-installed feature AVUT or field
upgrade 4L47A09132.

Light path diagnostics

All SR650 server models include basic light path diagnostics, which provides the system LEDs on the front of the
server (see
Components and
error LEDs on the system board).

Lenovo XClarity Provisioning Manager

Lenovo ThinkSystem SR650 Server
connectors).
connectors) and the LEDs near the monitored components (for example, the DIMM
Part
Feature
Maximum
number
code
supported
4L47A09132 AVUT
1
None*
AUPW
1
4L47A09133 None**
1
62

Hide quick links:

Advertisement

Table of Contents
loading