Fig. 7: Removing The Foot Mounting - ABB A175-M62 Operation Manual

Axial turbochargers for the largest medium-speed engines
Hide thumbs Also See for A175-M62:
Table of Contents

Advertisement

Operation Manual / 4 Product description / A100-M axial
2 Removal and installation / 2.2 Removing the turbocharger
Turbocharger with clamping nuts
Fig. 7: Removing the foot mounting
1. Loosen clamping nuts on compressor-end and turbine-end foot (see
clamping nut
→11).
2. Fit transport screws (90334 / 90335) to secure the sliding block (68003) on the left and
right on the turbine-end foot.
Lift the turbocharger from the engine and put it down.
u
Cover all oil connections.
u
© Copyright 2017 ABB. All rights reserved.