DME4io-ES/DME8i-ES/DME8o-ES
INITIALIZING
You can initialize the DME Satellite internal memory.
Select one of the following initialization types:
Initialize DME:
All scenes, preset parameter settings, and WAVE files excluding components and files saved with the File Storage
function will be deleted.
All the Utility settings will be reset to default values.
Delete All Data:
All stored component, scene, and preset parameter settings, WAVE fi les, and fi les saved via the File Storage function
will be deleted. The Utility settings will be set to default. Use this initialization type if the internal data is damaged or
corrupted. After initialization, transfer necessary components from DME Designer.
1. While the DME Satellite is turned off, set the dip switch on the rear panel to the following position, then turn on
the power to the unit.
RS-232C
RS-422
RS-232C
RS-422
Four [PEAK] indicators on the upper row on the front panel light up during the initialization process. Four [SIGNAL]
indicators on the lower row of the front panel fl ash when the initialization process is complete. Four [PEAK] indicators
on the lower row of the front panel fl ash if the initialization process fails.
Do not turn off the power to the DME Satellite during the initialization process to prevent possible damage to the device.
2. When initialization is complete, reset the dip switch to its previous position, then turn off and on the power to
the unit.
Be sure to reset the dip switch to the previous position to prevent possible damage to the device.