Siemens SIMATIC S7 EIP-200S System Manual

Ethernet/ip adapter distributed i/o system
Table of Contents

Advertisement

SIMATIC
S7
EIP-200S Ethernet/IP Adapter
Distributed I/O System
System Manual
06/2018
A5E44345053-AB
___________________
Preface
___________________
Product overview
EIP-200S Ethernet/IP
___________________
Adapter
___________________
Installation and wiring
___________________
Commissioning and
diagnostics
___________________
General technical
specifications
___________________
Order number
___________________
Dimension drawings
___________________
Address space of the ET
200S inputs and outputs
1
2
3
4
5
A
B
C

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC S7 EIP-200S

  • Page 1 ___________________ Preface ___________________ Product overview EIP-200S Ethernet/IP ___________________ SIMATIC Adapter ___________________ Installation and wiring EIP-200S Ethernet/IP Adapter ___________________ Commissioning and Distributed I/O System diagnostics ___________________ General technical specifications System Manual ___________________ Order number ___________________ Dimension drawings ___________________ Address space of the ET 200S inputs and outputs 06/2018 A5E44345053-AB...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    Siemens products that you are using, they can provide the fastest and most efficient answers to any problems you might encounter.
  • Page 4 Preface Documentation and information The following list shows a summary of the documentation packages or manuals related to the ET 200S system, which can be found on the Siemens Service & Support Website (http://support.automation.siemens.com) ● EIP-200S Ethernet/IP Adapter (this manual) ●...
  • Page 5: Table Of Contents

    Table of contents Preface ..............................3 Product overview ............................ 7 What are distributed I/O systems? .................... 7 What is the ET 200S distributed I/O system? ................7 The EIP-200S Ethernet/IP Adapter ..................11 Features and benefits of the EIP-200S Ethernet/IP Adapter ..........13 What is Device Level Ring (DLR)? ..................
  • Page 6 Table of contents Wiring the ET 200S ........................ 65 3.9.1 Wiring rules for the ET 200S ....................65 3.9.2 Wiring a terminal module with screw-type terminals .............. 65 3.9.3 Wiring a terminal module with spring terminals ..............66 3.9.4 Wiring a terminal module with Fast Connect ................. 68 3.9.5 Wiring terminal modules for power and electronic modules ..........
  • Page 7: Product Overview

    Product overview What are distributed I/O systems? Distributed I/O systems - area of application When a system is set up, the inputs and outputs from and to the process are often located centrally in the programmable logic controller. If there are inputs and outputs at considerable distances from the programmable logic controller, there may be long runs of cabling which are not immediately comprehensible, and electromagnetic interference may impair reliability.
  • Page 8 Product overview 1.2 What is the ET 200S distributed I/O system? View The illustration below shows an example of an ET 200S distributed I/O system configuration: EIP-200S Ethernet/IP Adapter Distributed I/O System System Manual, 06/2018, A5E44345053-AB...
  • Page 9 Product overview 1.2 What is the ET 200S distributed I/O system? ET 200S components The table below provides an overview of the most important components of the ET 200S system: Component Function Drawing Rail Carries the ET 200S. You mount the ET 200S on the rail.
  • Page 10 Product overview 1.2 What is the ET 200S distributed I/O system? Component Function Drawing Electronic module Is connected to the terminal module and determines the function: Digital input modules with 24 VDC, 120/230 VAC • and NAMUR Digital output modules with 24 VDC and •...
  • Page 11: The Eip-200S Ethernet/Ip Adapter

    EIP-200S Ethernet/IP Adapter module features The EIP-200S Ethernet/IP Adapter is a communications adapter for interfacing to the Siemens SIMATIC ET 200S distributed I/O system. It provides connectivity between an Ethernet/IP network and ET 200S power and I/O modules, and has the following features: ●...
  • Page 12 Product overview 1.3 The EIP-200S Ethernet/IP Adapter The following illustration shows the hardware features of the EIP-200S Ethernet/IP Adapter module: 24 VDC terminals The 24 VDC Quick Release terminal connector on the front of the EIP-200S Ethernet/IP Adapter module provides logic power for the adapter module itself. I/O features The EIP-200S Ethernet/IP Adapter provides the following I/O features: ●...
  • Page 13: Features And Benefits Of The Eip-200S Ethernet/Ip Adapter

    Product overview 1.4 Features and benefits of the EIP-200S Ethernet/IP Adapter Features and benefits of the EIP-200S Ethernet/IP Adapter The following table lists the features and benefits of the EIP-200S Ethernet/IP Adapter: Features Benefits Structure Finely-graduated modular design: Function-oriented, cost-optimized station design •...
  • Page 14: What Is Device Level Ring (Dlr)

    Product overview 1.5 What is Device Level Ring (DLR)? What is Device Level Ring (DLR)? DLR network A DLR network is a single-fault-tolerant ring network that is intended for the interconnection of automation devices without the need for more switches. This topology is also implemented at the device level.
  • Page 15: Eip-200S Ethernet/Ip Adapter

    EIP ET200 Configuration Tool for the EIP-200S Ethernet/IP Adapter. The manual can be found on the Companion Disk that shipped with the product, or downloaded from the Siemens Service & Support Website (http://support.automation.siemens.com). LED status indicators The EIP-200S Ethernet/IP Adapter module has three bi-color LEDs that provide diagnostic information about the current state of the device and provide an indication of any faults.
  • Page 16 EIP-200S Ethernet/IP Adapter LED status indicator: Network Status LED The bi-color Network Status LED indicates the current state of the EIP-200S Ethernet/IP Adapter communications link, as described in the following table: State Description Device is powered off, or is powered on but •...
  • Page 17: Operation

    EIP-200S Ethernet/IP Adapter 2.1 Operation Operation Operating modes The EIP-200S Ethernet/IP Adapter is a modular device capable of operating out of the box without any special configuration software. However, to take full advantage of advanced diagnostics and features, a configuration tool is required. The Companion Disk shipped with this product contains both the Configuration Tool and the EIP ET200 Configuration Tool User Manual.
  • Page 18 The EIP ET200 Configuration Tool is suggested for configuration of a EIP-200S Ethernet/IP Adapter in user configured mode. This tool is available on the Companion Disk that shipped with the product, or via download from the Siemens Service & Support Website (http://support.automation.siemens.com). I/O status byte...
  • Page 19 EIP-200S Ethernet/IP Adapter 2.1 Operation Reset behavior When the Adapter is reset, the outputs will be deactivated during the short period that the reset is in progress. The unit can be reset in the following ways: ● Cycling of primary device 24 VDC power ●...
  • Page 20: Parameters For The Eip-200S Ethernet/Ip Adapter

    EIP-200S Ethernet/IP Adapter 2.2 Parameters for the EIP-200S Ethernet/IP Adapter Parameters for the EIP-200S Ethernet/IP Adapter Parameter assignment Parameters for the EIP-200S Ethernet/IP Adapter are set by using the ZNX-EIP-200S Configuration Tool software. After loading new parameters into the interface module, the parameters take effect immediately.
  • Page 21: Faults / Diagnostics

    EIP-200S Ethernet/IP Adapter 2.3 Faults / diagnostics Faults / diagnostics Configuration faults Faults in the electronic module configuration/parameterization data are handled slightly differently depending on when they are detected. In any case, the following occurs: ● Adapter Object AdapterStatus attribute indicates the appropriate code. ●...
  • Page 22 EIP-200S Ethernet/IP Adapter 2.3 Faults / diagnostics Module hot swap The EIP-200S Ethernet/IP Adapter supports electronic module hot swap, which allows you to replace modules while the device is active on the network without removing power. A configuration mismatch due to an improper module substitution is considered a fault. A subsequent hot swap that results in a match between the original configuration and the new module configuration clears the fault and the EIP-200S Ethernet/IP Adapter resumes normal operation.
  • Page 23: Troubleshooting

    Module Status LED will be solid red. This condition could occur due to a hardware failure that prevents proper operation of the device. Replace the interface module, or contact your Siemens representative. Module Status LED is flashing red If the Module Status LED is flashing red, this is most likely due to a configuration error.
  • Page 24: Replacing A Faulty Eip-200S Adapter

    EIP-200S Ethernet/IP Adapter 2.5 Replacing a faulty EIP-200S Adapter Network Status LED is solid red The device fails the duplicate MAC ID check sequence during power-up due to a conflicting node ID. To recover, perform one of the following steps: ●...
  • Page 25: Device Profile: Supported Cip Objects

    EIP-200S Ethernet/IP Adapter 2.6 Device profile: supported CIP objects Device profile: supported CIP objects 2.6.1 Identity Object The following information applies to the Identity Object for the EIP-200S Ethernet/IP Adapter. Class code 0x01 Class attributes 1, 2, 3 Number of instances 1 Instance 1 attributes for Identity Object Attribute Access...
  • Page 26 EIP-200S Ethernet/IP Adapter 2.6 Device profile: supported CIP objects Device_Status definitions for Identity Object Bit(s) Called Definition Owned 0 = not owned 1 = the device has an owner Reserved Always 0 Configured 0 = "out-of-box" configuration 1 = configuration modified (not including communications) Reserved Always 0...
  • Page 27 EIP-200S Ethernet/IP Adapter 2.6 Device profile: supported CIP objects Extended Device Status - Bits 4-7 Bits 4-7 Extended Device Status Description 0 0 0 0 Self-testing or Unknown. 0 0 0 1 Firmware update in progress. 0 0 1 0 At least one faulted I/O connection.
  • Page 28: Assembly Object

    EIP-200S Ethernet/IP Adapter 2.6 Device profile: supported CIP objects 2.6.2 Assembly Object The following applies to the Assembly Object for the EIP-200S Ethernet/IP Adapter. Class code 0x04 Class attributes 1, 2, 3 Number of instances Class attributes for Assembly Object Attribute Access Description...
  • Page 29 EIP-200S Ethernet/IP Adapter 2.6 Device profile: supported CIP objects Instance 199 (C7 This instance is used to establish a connection based on an existing exclusive owner connection. The new connection also has the same transmission parameters as the exclusive owner connection. When the exclusive owner connection is cleared, this connection, too, is automatically cleared.
  • Page 30: Connection Manager Object

    EIP-200S Ethernet/IP Adapter 2.6 Device profile: supported CIP objects 2.6.3 Connection Manager Object The following information applies to the EIP-200S Ethernet/IP Adapter Connection Manager Object. Class code 0x06 Class attributes 1, 2, 3 Number of instances 1 Instance 1 attributes for Connection Manager Object Attribute Need in Access...
  • Page 31: Tcp/Ip Interface Object

    EIP-200S Ethernet/IP Adapter 2.6 Device profile: supported CIP objects 2.6.4 TCP/IP Interface Object The TCP/IP Interface Object provides the mechanism to configure the EIP200S Ethernet/IP Adapter’s TCP/IP network interface. Examples of configurable items include the device's IP address, network mask, gateway address, and host name. Class attributes 1, 2, 3 Class services...
  • Page 32 EIP-200S Ethernet/IP Adapter 2.6 Device profile: supported CIP objects Instance attributes for TCP/IP Interface Object Attribute Access Description Data type Default value Semantics of values rule Interface status DWORD 0x00000002 See table below: "Table for (Status) Interface status, attribute 1" Interface capa- DWORD 0x00000015...
  • Page 33 EIP-200S Ethernet/IP Adapter 2.6 Device profile: supported CIP objects Attribute Access Description Data type Default value Semantics of values rule TCP/IP network STRUCT Contains parameters re- interface config- quired to operate as a uration TCP/IP node. In order to prevent incomplete or incompatible configuration, the parameters cannot be set individually.
  • Page 34 EIP-200S Ethernet/IP Adapter 2.6 Device profile: supported CIP objects Attribute Access Description Data type Default value Semantics of values rule Host name STRING 0x00E (length = ASCII characters. Maxi- 14) plus hex mum length is 48 charac- equivalent of ters. Padded to an even "br+MAC"...
  • Page 35: Ethernet Link Object

    EIP-200S Ethernet/IP Adapter 2.6 Device profile: supported CIP objects 2.6.5 Ethernet Link Object The Ethernet Link Object maintains link-specific counters and status information for an IEEE 802.3 communications interface. The EIP-200S Ethernet/IP Adapter has an embedded 2-port switch and has two instances of the Ethernet Link Object (one for each port). Class attributes 1, 2, 3 Class services...
  • Page 36 EIP-200S Ethernet/IP Adapter 2.6 Device profile: supported CIP objects Attribute Access Name Description Data type Semantics of values rule Interface Configuration for physi- STRUCT See section "Interface Control cal interface Control" below. Control Bits Interface Control Bits WORD ---- Forced Speed at which the UINT Speed in Mbps (10, 100,...
  • Page 37 EIP-200S Ethernet/IP Adapter 2.6 Device profile: supported CIP objects Interface Flags attribute Bit(s): Called: Definition Link Status Indicates whether the IEEE 802.3 communications interface is connected to an active network: 0 = inactive link 1 = active link The determination of link status is implementation specific Half/Full Duplex Indicates the duplex mode currently in use: 0 = interface is running half duplex...
  • Page 38 EIP-200S Ethernet/IP Adapter 2.6 Device profile: supported CIP objects Media Counters (STRUCT of) Name Data Type Description of Attribute Alignment Errors UDINT Frames received that are not an integral number of oc- tets in length FCS Errors UDINT Frames received that do not pass the FCS check Single Collisions UDINT Successfully transmitted frames which experienced ex-...
  • Page 39 EIP-200S Ethernet/IP Adapter 2.6 Device profile: supported CIP objects Control Bits operate as follows: Bit(s) Called: Definition Autonegotiate 0 = 802.3 link autonegotiation is disabled. 1 = autonegotiation is enabled. If autonegotiation is disabled, the device uses the settings indicat- ed by the Forced Duplex Mode and Forced Interface Speed bits.
  • Page 40: Device Level Ring (Dlr) Object

    EIP-200S Ethernet/IP Adapter 2.6 Device profile: supported CIP objects Common services for Ethernet Link Object Service Need in implementation Service name Description code Class Instance 0x01 Optional Optional Get_Attribute_All Supplies contents of all attrib- utes. 0x0E Conditional Required Get_Attribute_Single Supplies contents of the appro- priate attribute.
  • Page 41: Quality Of Service (Qos)

    EIP-200S Ethernet/IP Adapter 2.6 Device profile: supported CIP objects Instance attributes Attribute Access rule Name Data type Description of Attribute Semantics of values Get required Network Topology USINT Current network topolo- 0 - indicates "Linear" gy mode 1 - indicates "Ring" Get required Network Status USINT...
  • Page 42 EIP-200S Ethernet/IP Adapter 2.6 Device profile: supported CIP objects Class attributes The QoS object supports the following class attributes: Attribute ID Access rule Description Data type Default value Revision UINT 0x0001 Maximum number of instances UINT 0x0001 Number of instances UINT 0x0001 Instance attributes...
  • Page 43: Device Profile: Vendor-Specific Objects

    EIP-200S Ethernet/IP Adapter 2.7 Device profile: vendor-specific objects Device profile: vendor-specific objects 2.7.1 Adapter Object The Adapter Object provides the external configuration and monitoring interface to the EIP-200S Ethernet/IP Adapter. Class code 0x64 Class attributes No attributes are supported for the Adapter Object at the class level. Number of instances 1 Instance 1 attributes of the Adapter Object Attribute...
  • Page 44 EIP-200S Ethernet/IP Adapter 2.7 Device profile: vendor-specific objects Attribute Access rule Name Data type Data value Get/Set HeadParamByte11 USINT Get/Set HeadParamByte12 USINT Get/Set HeadParamByte13 USINT Get/Set HeadParamByte14 USINT Get/Set HeadParamByte15 USINT Get/Set HeadParamByte16 USINT Get/Set HeadParamByte17 USINT Get/Set HeadParamByte18 USINT Get/Set HeadParamByte19 USINT...
  • Page 45 EIP-200S Ethernet/IP Adapter 2.7 Device profile: vendor-specific objects Attribute 6 [Diagnostic String] details EIP-200S Ethernet/IP Adapter Distributed I/O System System Manual, 06/2018, A5E44345053-AB...
  • Page 46 EIP-200S Ethernet/IP Adapter 2.7 Device profile: vendor-specific objects Adapter Object: Standard diagnostic data Byte 0 Station state 1 Byte 1 Station state 2 Byte 2 Station state 3 Byte 3 Master address Byte 4 Ident number (low) Byte 5 Ident number (high) The structure of the standard diagnostic data is as follows: Byte Bit(s)
  • Page 47: Slot Object

    EIP-200S Ethernet/IP Adapter 2.7 Device profile: vendor-specific objects Common services for the Adapter Object Service Implemented for code Service name Class Instance 0x0E Get_Attribute_Single 0x10 Set_Attribute_Single 2.7.2 Slot Object The following information applies to the Slot Object for the EIP-200S Ethernet/IP Adapter. The Slot Object provides the external configuration and monitoring interface to the I/O module in one slot.
  • Page 48 EIP-200S Ethernet/IP Adapter 2.7 Device profile: vendor-specific objects Attribute Access rule Name Data type Data value Channel0Type USINT Channel Type code (see Attribute 14-21 ta- ble). The Channel Type code is zero if the Channel1Type USINT corresponding Channel Status code is zero. Channel2Type USINT Channel3Type...
  • Page 49 EIP-200S Ethernet/IP Adapter 2.7 Device profile: vendor-specific objects Attribute Access rule Name Data type Data value Get / Set ParamByte30 USINT Get / Set ParamByte31 USINT Get / Set ParamByte32 USINT When Adapter Object AutoConfig attribute is true: These attributes reflect the nonvolatile configu- ration parameters and are not used by the Adapter.
  • Page 50 EIP-200S Ethernet/IP Adapter 2.7 Device profile: vendor-specific objects Attribute 6-13 [Channel<n>Status] details The Channel<n>Status attributes, listed in the following table, report the operating status of each channel in the module: Status code Text Short circuit Under voltage Over voltage Overload Excess temperature Wire break Over range...
  • Page 51 EIP-200S Ethernet/IP Adapter 2.7 Device profile: vendor-specific objects Attribute 14-21 [Channel<n>Type] details The Channel<n>Type attributes, listed in the following table, provide additional detail when the corresponding Channel<n>Status is reporting an error. Status code Text Description Reported when corresponding Channel<n>Status is reporting "No error"...
  • Page 52: Technical Specifications

    EIP-200S Ethernet/IP Adapter 2.8 Technical specifications Technical specifications SIMATIC DP, interface module EIP-200S Ethernet/IP Adapter:2 Ethernet ports with RJ45 connectors; up to 2 m width connectable to a maximum of 63 power, electrical, or motor starter modules. SUPPLY VOLTAGE Power supply hold-up time Hold-up time, min.
  • Page 53: Installation And Wiring

    Installation and wiring Installation Simple installation The ET 200S distributed I/O system is designed for simple installation. The modules of an ET 200S system are classified as Open Equipment. You must install the ET 200S in cases, cabinets or electrical control rooms where they will only be accessible with a key or a tool.
  • Page 54: Installing The Eip-200S Ethernet/Ip Adapter

    Installation and wiring 3.3 Installing the EIP-200S Ethernet/IP Adapter Installing the EIP-200S Ethernet/IP Adapter Features ● The EIP-200S Ethernet/IP Adapter connects the ET 200S with the network. ● The EIP-200S Ethernet/IP Adapter transfers data between the higher-level controller and the I/O modules. Prerequisites The prerequisites for installation are shown below ●...
  • Page 55: Inserting And Identifying The Electronic Modules

    Installation and wiring 3.4 Inserting and identifying the electronic modules Inserting and identifying the electronic modules Features ● The electronic modules are inserted in the terminal modules. ● A labeling strip allows you to identify the electronic modules. ● Electronic modules are: –...
  • Page 56 Installation and wiring 3.4 Inserting and identifying the electronic modules Removing electronic modules To remove electronic modules, follow the steps below: 1. Simultaneously press the two release buttons on the top and bottom of the electronic module. 2. Pull the electronic module out from the terminal module at the front. The following diagram illustrates removing electronic modules: EIP-200S Ethernet/IP Adapter Distributed I/O System System Manual, 06/2018, A5E44345053-AB...
  • Page 57 Installation and wiring 3.4 Inserting and identifying the electronic modules Changing the type of an electronic module Assuming you have already removed the electronic module, follow the steps below to change the type of electronic module: 1. Use a screwdriver to push the code element out of the terminal module. 2.
  • Page 58 Installation and wiring 3.4 Inserting and identifying the electronic modules Replacing a defective electronic module Assuming you have already removed the electronic module, follow the steps below to replace a defective electronic module: 1. Remove the code element from the bottom of the new electronic module. 2.
  • Page 59: Wiring And Setup

    Installation and wiring 3.5 Wiring and setup Wiring and setup Prewiring The ET 200S distributed I/O system allows you to prewire the terminal modules with screw-type or spring terminals. General rules and regulations for operating the EIP-200S Ethernet/IP Adapter Introduction When operating the ET 200S distributed I/O system as a component part of a plant or system, certain rules and regulations have to be followed depending on where the device is to be used.
  • Page 60 Installation and wiring 3.6 General rules and regulations for operating the EIP-200S Ethernet/IP Adapter Line voltage The following table tells you what you should do with regard to the line voltage: With: Requirements: Permanently installed plants or systems without There must be a line disconnect switch or a fuse all-pole line disconnect switches in the building installation system.
  • Page 61: Operating The Et 200S On A Grounded Supply

    Installation and wiring 3.7 Operating the ET 200S on a grounded supply Operating the ET 200S on a grounded supply In this section, you will find information on the overall setup of an ET 200S distributed I/O system on a grounded supply (TN-S system). The specific subjects discussed are: ●...
  • Page 62 Installation and wiring 3.7 Operating the ET 200S on a grounded supply Overall configuration of the ET 200S The following illustration shows the overall configuration of the ET 200S distributed I/O system (load voltage supply and grounding concept) with supply from a TN-S system. EIP-200S Ethernet/IP Adapter Distributed I/O System System Manual, 06/2018, A5E44345053-AB...
  • Page 63 Installation and wiring 3.7 Operating the ET 200S on a grounded supply Grounded supply In a grounded supply, the neutral conductor of the system is grounded. A mere ground fault between a live conductor and ground or a grounded section of the plant causes the protective devices to trip.
  • Page 64: Electrical Design Of The Et 200S

    Installation and wiring 3.8 Electrical design of the ET 200S Electrical design of the ET 200S Isolation between: The ET 200S provides isolation between the following components: ● The load circuits/process and all other circuit components of the ET 200S ●...
  • Page 65: Wiring The Et 200S

    Installation and wiring 3.9 Wiring the ET 200S Wiring the ET 200S 3.9.1 Wiring rules for the ET 200S Wiring rules for: Interface voltage Terminal modules Terminal modules (supply voltage) (spring and screw- (Fast Connect) type terminals) Connectable wire cross-sections for 0.14 to 2.5 mm 0.5 to 1.5 mm rigid lines...
  • Page 66: Wiring A Terminal Module With Spring Terminals

    Installation and wiring 3.9 Wiring the ET 200S Wiring a terminal module with a screw-type terminal To wire a terminal module with a screw-type terminal, follow these steps: 1. Strip 11 mm (0.43 in) of insulation from the wires. 2. Insert the individual wires in the terminal. 3.
  • Page 67 Installation and wiring 3.9 Wiring the ET 200S Wiring a terminal module with spring terminals To wire a terminal module with a spring terminals, follow these steps: 1. Strip 11 mm (0.43 in) of insulation from the wires. 2. Insert the screwdriver in the upper (round) opening of the terminal. 3.
  • Page 68: Wiring A Terminal Module With Fast Connect

    Installation and wiring 3.9 Wiring the ET 200S 3.9.4 Wiring a terminal module with Fast Connect Features ● In the case of terminal modules with Fast Connect, the individual wires are attached using a quick connection method that requires no stripping. ●...
  • Page 69 Installation and wiring 3.9 Wiring the ET 200S Wiring terminal modules with Fast Connect 1. Insert the unstripped cable in the round opening until it stops (the insulation and conductor must form a flat surface). 2. Insert the screwdriver into the opening above the locking mechanism until it stops. 3.
  • Page 70 Installation and wiring 3.9 Wiring the ET 200S Releasing the wiring of the terminal module with Fast Connect 1. Insert the screwdriver into the opening below the locking mechanism until it stops. 2. Use the screwdriver to lever and push the locking mechanism upward. 3.
  • Page 71 Installation and wiring 3.9 Wiring the ET 200S Removing any remains of the conductor (only if necessary) To remove any remains of the conductor (insulation), you can uninstall the locking mechanism from the terminal module (see Step 3). To do this, the locking mechanism must be open (upper position).
  • Page 72: Wiring Terminal Modules For Power And Electronic Modules

    Installation and wiring 3.9 Wiring the ET 200S 3.9.5 Wiring terminal modules for power and electronic modules Features The ET 200S distributed I/O system comprises terminal modules for power modules and electronic modules: ● At the terminal modules for the power modules, you connect the supply/load voltage for the respective potential group.
  • Page 73 Installation and wiring 3.9 Wiring the ET 200S Wiring terminal modules for digital, analog, and process-related modules The terminal assignment of the terminal module depends on which electronic module is inserted. The following diagram illustrates wiring terminal modules for electronic modules: EIP-200S Ethernet/IP Adapter Distributed I/O System System Manual, 06/2018, A5E44345053-AB...
  • Page 74 Installation and wiring 3.9 Wiring the ET 200S Connecting cable shields We recommend you use the shield contact to connect cable shields (in the case of analog electronic modules, the 1COUNT 24V/100kHz electronic module and the 1SSI electronic module, for example). To connect cable shields, perform the following steps: 1.
  • Page 75 Installation and wiring 3.9 Wiring the ET 200S The following diagram illustrates connecting cable shields: Note To stabilize the shield contact, you must mount and screw in at least one shield terminal over the shield contact element. EIP-200S Ethernet/IP Adapter Distributed I/O System System Manual, 06/2018, A5E44345053-AB...
  • Page 76: Wiring The Eip-200S Ethernet/Ip Adapter

    Installation and wiring 3.9 Wiring the ET 200S 3.9.6 Wiring the EIP-200S Ethernet/IP Adapter Features You can connect the supply voltage to the EIP-200S Ethernet/IP Adapter. Prerequisites Prerequisites for wiring the EIP-200S Ethernet/IP Adapter are shown below: ● Wire the interface module power connector with the supply voltage switched off. ●...
  • Page 77 Installation and wiring 3.9 Wiring the ET 200S Wiring the EIP-200S Ethernet/IP Adapter interface module To connect the supply voltage, follow these steps: 1. Strip the insulation from the wires for the supply voltage of the interface module. 2. Depress the orange wire release slot with a screwdriver and, while holding it down, insert the stripped wire.
  • Page 78 Installation and wiring 3.9 Wiring the ET 200S EIP-200S Ethernet/IP Adapter Distributed I/O System System Manual, 06/2018, A5E44345053-AB...
  • Page 79: Commissioning And Diagnostics

    Commissioning and diagnostics Configuring the ET 200S Introduction This section describes how to configure and assign parameters to the ET 200S: ● Configuration: The systematic arrangement of the different ET 200S modules (setup) ● Parameter assignment: Setting the ET 200S parameters using the configuration software Configuration The ET 200S has address space of up to 255 bytes for inputs and 255 bytes for outputs.
  • Page 80 Commissioning and diagnostics 4.1 Configuring the ET 200S Procedure for groupable modules In the hardware catalog of your configuration software, you can recognize groupable modules by the fact that they are available in duplicate. The modules differ from each other only by a "...
  • Page 81 Commissioning and diagnostics 4.1 Configuring the ET 200S Grouping of modules in Automatic Configuration mode (default) Grouping of modules in User Configured mode EIP-200S Ethernet/IP Adapter Distributed I/O System System Manual, 06/2018, A5E44345053-AB...
  • Page 82 Commissioning and diagnostics 4.1 Configuring the ET 200S Grouping of Motor Starters Configuration example The following example describes how to use User Configured mode in the configuration of an ET 200S setup: Setup of the ET 200S EIP-200S Ethernet/IP Adapter Distributed I/O System System Manual, 06/2018, A5E44345053-AB...
  • Page 83 Commissioning and diagnostics 4.1 Configuring the ET 200S Configuration table in your configuration software and address space The byte and bit addresses result from the sequence of the grouped modules in User Configured mode. Slot Module Grouping I/O address Inputs Outputs 6ES7138-4CA00-0AA0 PM-E 24 VDC 6ES7131-4BB00-0AB0 2DI 24 VDC...
  • Page 84: Commissioning And Startup Of The Et 200S

    Commissioning and diagnostics 4.2 Commissioning and startup of the ET 200S Commissioning and startup of the ET 200S Software requirements To configure the EIP-200S Ethernet/IP Adapter interface module, use the ZNX-EIP-200S Configuration Tool software package. Refer to its documentation for information on how to configure the system.
  • Page 85: Using Quickconnect

    Commissioning and diagnostics 4.5 Using QuickConnect Using QuickConnect What is QuickConnect? QuickConnect technology enables Ethernet/IP devices to quickly power up and join an Ethernet/IP network. Examples of typical implementations might include the following: ● A robotic application where a robot arm quickly exchanges tools to switch tasks. ●...
  • Page 86: Guidelines For Using Quickconnect On Your Network

    Commissioning and diagnostics 4.5 Using QuickConnect Advantages of using QuickConnect QuickConnect accelerates the startup of distributed I/O devices. It shortens the time that the respective configured distributed I/O devices require in order to reach the cyclic user data exchange in the following cases: ●...
  • Page 87 Commissioning and diagnostics 4.5 Using QuickConnect QuickConnect system guidelines The following guidelines are required in order to enable setup with QuickConnect: System component Guidelines Tool side devices Use a preconfigured, static IP address for the devices. This removes • DHCP/BOOTP cycle time. Configure the devices for 100 Mbps, full-duplex operation in both the •...
  • Page 88 Commissioning and diagnostics 4.5 Using QuickConnect QuickConnect sequence The following steps describe a robot system as an example: 1. The controller inhibits current connections to QuickConnect modules, and the robot arm physically disengages the current tool. 2. The robot arm physically attaches a new QuickConnect module. 3.
  • Page 89: Replacing A Faulty Quickconnect Adapter

    Commissioning and diagnostics 4.5 Using QuickConnect Wiring rules for disabled autonegotiation With auto crossover (MDIX) turned off, the EIP-200S ports are set as follows: ● Port 1 - normal (straight-through) pin assignment ● Port 2 - crossed over pin assignment Crossed over pin assignment means that the pin assignment for the ports for sending and receiving between devices is exchanged internally.
  • Page 90: Firmware Updates

    Commissioning and diagnostics 4.6 Firmware updates Timing errors Once your initial system is configured, it is recommended that you test whether the connection timing is within your required timeframe. A QuickConnect I/O device issues a gratuitous ARP message on the network every 25 ms for a maximum of 40 times (1 second) until an I/O connection is established.
  • Page 91: General Technical Specifications

    It is the user's responsibility to determine applicable certifications by referring to the ratings marked on the product. Consult your local Siemens representative if you need additional information related to the latest listing of exact approvals by part number.
  • Page 92 Potentially Explosive Atmosphere" – EN 60079-15:2005: Type of Protection 'n' The CE Declaration of Conformity is held on file and available to competent authorities at: Siemens AktiengesellschaftAutomation and DrivesA&D AS RD4Postfach 1963D-92209 Amberg, Germany cULus approval Underwriters Laboratories Inc. complying with: ●...
  • Page 93 Risk of substituion of components Substitution of components can impair the suitability for Class I, Division 2 and Zone 2. Repair of units should only be performed by an authorized Siemens Service Center. ATEX approval ATEX approval applies to DC models only. ATEX approval does not apply to AC and Relay models.
  • Page 94 General technical specifications 5.2 Standards Compliance Industrial environments The ET 200S distributed I/O system is designed for use in industrial environments. Table 5- 1 Industrial environments Application field Noise emission requirements Noise immunity requirements Industrial EN 61000-6-4:2007 EN 61000-6-2:2005 Electromagnetic compatibility Electromagnetic Compatibility (EMC) is the ability of an electrical device to operate as intended in an electromagnetic environment and to operate without emitting levels of electromagnetic interference (EMI) that may disturb other electrical devices in the vicinity.
  • Page 95 General technical specifications 5.2 Standards Compliance Environmental conditions Table 5- 4 Transport and storage Environmental conditions - Transport and storage EN 60068-2-2, Test Bb, Dry heat and -40° C to +70° C EN 60068-2-1, Test Ab, Cold EN 60068-2-30, Test Db, Damp heat 25°...
  • Page 96 General technical specifications 5.2 Standards Compliance Degree of protection ● IP20 Mechanical Protection, EN 60529 ● Protects against finger contact with high voltage as tested by standard probe. External protection required for dust, dirt, water and foreign objects of < 12.5mm in diameter. Rated voltages Table 5- 7 Rated voltages...
  • Page 97 General technical specifications 5.2 Standards Compliance DC Outputs Short circuit protection circuitry is not provided for DC outputs on signal modules unless otherwise stated. Relay electrical service life The typical performance data supplied by relay vendors is shown below. Actual performance may vary depending upon your specific application.
  • Page 98: Use Of Subassemblies/Modules In A Zone 2 Hazardous Area

    Below you will find important information on the installation of the subassemblies/modules in a hazardous area. You can find the list of approved devices/modules on the Siemens Service & Support Website/ (http://support.automation.siemens.com). Enter the associated article ID in the search window on the website. See table below for article IDs by product.
  • Page 99 General technical specifications 5.3 Use of subassemblies/modules in a Zone 2 hazardous area Zone Explosion hazard Example Explosive gas atmosphere occurs Areas around flange joints with flat gaskets only seldom and for a short time in pipes in enclosed spaces Safe area Outside zone 2 •...
  • Page 100 General technical specifications 5.3 Use of subassemblies/modules in a Zone 2 hazardous area Special conditions for KEMA 04 ATEX 1151X Special conditions for the KEMA 04 ATEX 1151X is shown below: ● The connecting or disconnecting of live conductors or operation of device switches (for example, for installation or servicing purposes) is only allowed when it has been ensured that the area is not explosive.
  • Page 101 General technical specifications 5.3 Use of subassemblies/modules in a Zone 2 hazardous area WARNING Explosion hazard Components may no longer qualify for Class I, Div. 2 if they are substituted. WARNING This device is only appropriate for use in Class I, Div. 2, Group A, B, C, D, or in non-hazardous areas.
  • Page 102 General technical specifications 5.3 Use of subassemblies/modules in a Zone 2 hazardous area EIP-200S Ethernet/IP Adapter Distributed I/O System System Manual, 06/2018, A5E44345053-AB...
  • Page 103: Order Number

    Order number Designation Order number EIP-200S Ethernet/IP Adapter interface module package ZNX-EIP-200S SD memory card 6ES7954-8LC03-0AA0 EIP-200S Ethernet/IP Adapter Distributed I/O System System Manual, 06/2018, A5E44345053-AB...
  • Page 104 Order number EIP-200S Ethernet/IP Adapter Distributed I/O System System Manual, 06/2018, A5E44345053-AB...
  • Page 105: Dimension Drawings

    Dimension drawings Introduction Following are dimension drawings of the ET 200S system and EIP-200S Ethernet/IP Adapter. Minimum clearances for installation, wiring, and ventilation for ET 200S EIP-200S Ethernet/IP Adapter Distributed I/O System System Manual, 06/2018, A5E44345053-AB...
  • Page 106 Dimension drawings EIP-200S Ethernet/IP Adapter front and side views EIP-200S Ethernet/IP Adapter Distributed I/O System System Manual, 06/2018, A5E44345053-AB...
  • Page 107: Address Space Of The Et 200S Inputs And Outputs

    Address space of the ET 200S inputs and outputs Address area of the modules The following table shows address area inputs and outputs for the ET 200S. Module Address space of the inputs Address space of the outputs Without group- With grouping Without group- With grouping...
  • Page 108 Address space of the ET 200S inputs and outputs EIP-200S Ethernet/IP Adapter Distributed I/O System System Manual, 06/2018, A5E44345053-AB...
  • Page 109: Index

    Index Configuration, 62, 79 maximum, 54 ConfiguredSlot, 43 Connection Manager Object, 30 24 VDC connector, 12 Control Bits, 36, 38 24 VDC supply, 60 C-Tick approval, 93 cULus approval, 92 Adapter Object, 43 AdapterStatus, 43 DC output protection, 97 Address area, 52, 107 Degree of protection, 96 Address space, 11, 79 Device Level Ring (DLR), 14...
  • Page 110 Index Environmental industrial environments, 94 I/O features, 12 operating conditions, 95 I/O status byte, 18, 46 transport and storage conditions, 95 Identity Object, 25 Environmental conditions, 95 IEC 204, 59 ET 200S Immunity, 94 components - diagrams, 9 Industrial environments, 94 ET 200S distributed I/O system, 7 Input current, 52 Ethernet Link Object, 35...
  • Page 111 Index Measurements Parameter length for installation, 53 maximum, 11 Media Counters (STRUCT of), 38 Parameters ModuleReference, 47 bus length, 20 Modules ParameterSize, 47 electronic, 10 Physical address, 35 power, 9 Potentials, 64 terminal, 9 Power loss, 52 terminating, 10 Power module, 9, 72 Motor starters, 79 Prewiring, 59 grouping, 82...
  • Page 112 Index speed Duplex Options, 36 Spring terminals, 66 Zone 2, 98 Startup post-event, 59 Storage, 95 TCP/IP Interface Object, 31 Technical specifications, 52, 91, 91 Temperature, 99 Terminal module, 9 Terminal module installation, 54 Terminal modules, 7 wiring, 72 Terminals screw-type, 65 spring, 66 Terminating module, 10...

Table of Contents