INSTALLATION
INSTALLATION
Piping
in the Well
The Shallow
Well Water
System
can be installed
on a dug
well, drilled
well or with
a driven
point.
In a dug or cased
well,
a foot valve
and strainer
should
be installed
for easy
priming.
It should
be installed
five to ten feet below
the low-
est level to which
the water vdll drop while the pump
is op-
erating
(pumping
water
level).
To keep
sediment
from
clogging
the strainer,
be sure it is five to ten feet above
the
bottom
of the well. Before installing
the foot valve,
make
sure that it works
freely.
When
using a foot valve, a priming
tee and plug as shown
in
Figure 1, are recommended.
Priming Plug,
Priming Tee
(User Supplied)
From
Well
For a pump
at sea level mounted
directly
over the well, be
sure the total lift from the pumping
water level to the pump
does not exceed
20 feet. This will be less if the pump
is off-
set from
the well.
The maximum
lift of any pump
decreases
at the rate of about
1' less lift for every
1,000 feet of elevation
above
sea level.
For example,
at Denver,
Colorado
0Elev. 5,000')
the pump
loses
five feet of lift. The maximum
depth
from which
it
would
pump
water
would
therefore
be 15 feet.
Plastic Pipe
Figure 2B
Well Seal
and Strainer
;11 1293
Dug or Cased Well
Figure
I
When
installed
on a driven
point
well, your
Shallow
Well
Water
System
should
have a check
valve installed
as shown
in Figure 2A.
[_eck
Valve
t
Steel Drive Pipe
D,.__dve coupling
Well point
Figure
2A
_
Driven point
PUMP/TANK
INSTALLATION
Pump
NOTICE:
Use Teflon
tape supplied
with the pump
or Plasto-
Joint
Stik' for making
all pipe-thread
connections
to the
pump
itself. To avoid stress-crocking,
do not use pipe joint
compounds
on the pump.
1. Wrap male
pipe threads being
attached
to pump
with
one or two layers of Teflon
tape. Cover
entire
threaded
portion
of pipe.
2. Do not overtighten
threaded
fittings in the plastic pump.
Be sure you do not try to tighten
joint past thread stop
in pump
port!
3. If leaks occur,
remove
fittings,
clean offold
tape, rewrap
with
two to three
layers of tape
and remake
the con-
nection.
If joint still leaks,
replace
the fittings
(fittings
may be undersized).
4. Be sure to support
all piping
connected
to the System.
_Lake Chemical
Co., Chicago,
Illinois
Horizontal
Piping from
Well
to Pump
When
the pump
is offset more
than 25 feet from the well,
horizontal
suction
pipe
size should
be increased
to reduce
friction
losses.
Never
install
a suction
pipe
that is smaller
than the suction
tapping
of the pump.
4