Connecting Analog Input Devices - Bosch AMC2 Installation Manual

Modular controller
Hide thumbs Also See for AMC2:
Table of Contents

Advertisement

AMC2 Modular Controller
4.15

Connecting Analog Input Devices

The AMC2-4R4 has 8 analog inputs, for example, for potential-free lock mechanisms, or to
detect whether a lock is closed or open. The inputs will be connected to the 2-pin pluggable
screw connectors: S3, S4, S8, S9, S15, S16, S20 and S21 - refer to Connecting Diagrams, page
44.
Notice!
Risk of damage to equipment
Do not connect external power supply to the AMC2 inputs.
When connecting a relay output to an AMC2 input use dry mode with potential-free contact -
refer to Connecting Relay Outputs, page 30.
Figure 4.23: Location of the analog input connectors
The AMC2-4R4 can also detect the wiring conditions 'short circuit' and 'broken', and hence
trigger an alarm if the appropriate devices are connected.
1. Door open: R
2. Door closed: R
3. Open wire: R
4. Short circuit: R
Bosch Access Systems GmbH
+ R
S
P
S
+ R
= ∞
S
P
+ R
= 0
S
P
Installation Manual
Installing | en
33
2018-02 | AMC2-4R4 |