ABB Welcome
®
Lift control module
M2306
M2307
=== E nde der Liste für Tex tma rke C over == =

Advertisement

Table of Contents
loading

Summary of Contents for ABB Welcome M2307

  • Page 1 Pos: 2 /DinA4 - Anl eitun gen Online /Inh alt/KNX/Doo rEntry /832 20-AP- xxx/Tit elblat t - 832 20-AP-xxx - ABB @ 1 9\m od_ 132 3249 806 476 _15. docx @ 11 108 4 @ @ 1 — VER: 1.3 | 02.20.2017 ABB Welcome ®...
  • Page 2: Table Of Contents

    Pos: 4 /Busc h-Ja ege r (N eust rukt ur)/ Mo dul-St ruktu r/Onli ne-D oku ment ation /Inh altsve rzeich nis ( --> Fü r alle Doku men te <-- )/In haltsve rzeic hnis @ 19\ mod _13 206 490 4438 6_1 5.d ocx @ 109 653 @ @ 1 Safety ....................... 3 Environment ..................... 3 ABB devices ................3 Technical data ..................4 Function ....................5 Connection ....................
  • Page 3: Safety

    ABB devices All packaging materials and devices from ABB bear the markings and test seals for proper disposal. Always dispose of the packaging material, electronic devices and their components via an authorized collection facility or disposal company.
  • Page 4: Technical Data

    ® ABB Welcome Technical data General Single-wire 2 x 22 AWG - 2 x 18 AWG clamps Fine-wire clamps 2 x 22 AWG - 2 x 18 AWG Bus voltage 20 V - 30 V DC Size Protection IP 20 Operating -13 °F to +131 °F...
  • Page 5: Function

    ® ABB Welcome Function The lift control modules include the M adaptor (M2306) and lift control relay module (M2307). These two devices together ensure that elevator (lift) only goes to authorized floor(s). If a resident presses the “unlock” button when receiving a guest's call from the outdoor station, or the authorized user swipes the registered card or enters the correct password, the elevator will automatically go down to the floor where the outdoor station is installed.
  • Page 6: Connection

    ® ABB Welcome Connection M2306 Fig. 1 Function Status - ON = Connected with the system controller and internal bus - OFF = Not connected with the system controller and internal bus - Blinking = Working with the system controller and internal bus...
  • Page 7 ® ABB Welcome M2307 Fig. 2 Function Power LED - ON = Power on - OFF = Power off Setting LED - Blinks when working normally. Address Set the module address. The address range is 1-16. Only the left 4 bits are used.
  • Page 8: Lift Control Relay Module Address By Binary Setting

    ® ABB Welcome Lift control relay module address by binary setting Fig. 3 Installer need only read the labeling on the lift control module and adjust according to the given position. Only digits 1-2-3-4 are used. — 8 —...
  • Page 9: Mounting And Installation

    ® ABB Welcome Mounting and installation Warning Electric voltage! Direct or indirect contact with live components can cause dangerous currents to flow through the body, which may result in electric shock, burns or even death. Always disconnect the main power supply prior to installation and/or disassembly.
  • Page 10: Requirements For The Electrician

    ® ABB Welcome Requirements for the electrician Warning Electric voltage! Install the device only if you have the necessary qualifications. Incorrect installation endangers your life and that of the user of the electrical system. Incorrect installation can cause serious damage to property, such as a fire.
  • Page 11: Mounting

    ® ABB Welcome Mounting The device must only be installed on mounting rails according to DIN EN 50022. It is highly recommended that M2306 be installed in the elevator motor room on the top floor or the electrical riser, while M2307 should be installed in the elevator cabin.
  • Page 12: User Case

    ® ABB Welcome Application examples High building (no more than 16 floors) with one elevator One M2306 and one M2307 Fig. 6: Topology — 12 —...
  • Page 13 ® ABB Welcome Wiring with one M2306 and one M2307 Fig. 7 — 13 —...
  • Page 14: High Building (More Than 16 Floors) With One Elevator

    ® ABB Welcome High building (more than 16 floors) with one elevator One M2306 and multiple (up to 16) M2307 units Fig. 8: Topology — 14 —...
  • Page 15 ® ABB Welcome Wiring with one M2306 and multiple M2307 units Fig. 9 Notes: The first mini system controller (M2301) feeds one M2306 and one M2307. An additional M2307 should be locally powered by one mini system controller. For example, with four M2307 units and one M2306, four mini system controllers are needed.
  • Page 16: High Building (More Than 16 Floors) With Two Elevators

    ® ABB Welcome High building (more than 16 floors) with two elevators One M2306 and multiple M2307 units support two elevators Fig. 10: Topology Note: The address code cannot be repeated. — 16 —...
  • Page 17: High Building (More Than 16 Floors) With Four Elevators

    ® ABB Welcome High building (more than 16 floors) with four elevators Two M2306 and multiple M2307 units support four elevators Fig. 11: Topology Note: The address code cannot be repeated. — 17 —...
  • Page 18: Operation

    User scenario illustration of visitor target floor 5. The visitor 2. The resident presses the "unlock" button reaches the at any ABB-Welcome indoor station. 12th floor. 4. The visitor has a set time (default of 10 minutes) in which to activate the 12 floor button in the elevator.
  • Page 19: User Scenario Illustration Of Resident Target Floor

    ® ABB Welcome User scenario illustration of resident target floor 4. The resident reaches 3. The resident has the 12th floor. a set time (default of 10 minutes) in which to activate the 12th floor button in the elevator. Other...
  • Page 20: Configuration Through Pc Software

    Connected to PC During configuration, the lift control adaptor can be connected directly to the PC so that the installed software (ABB Welcome PC Configuration Tool) can be used. Essentially, there is no need for local power supply during configuration.
  • Page 21: Configuration

    ® ABB Welcome Configuration Basic Steps Step 1: Set basic parameters of the apartment using the ABB Welcome configuration tool. Fig. 15 Function Select building number. Select floor number. Select apartment number. Set physical address (e.g., 13 indicates the IS address set by IS switches) Set user name Set logical address (e.g., 0703 indicates 7th floor, apartment number 3).
  • Page 22 ® ABB Welcome Step 2: Select building, M2307 and configure parameters of each relay Fig. 16 Function Select building number. Select M2307 number. Click “Add” to add a new M2307. Select ON or OFF for connecting the relay. Select NO or NC for output type.
  • Page 23 ® ABB Welcome Step 3: Associate outdoor station with M2307 Fig. 17 Function Building number (same as step 2). Select outdoor station number. Select relay number of M2307. Click “Add” to associate outdoor station with relay. Send all parameters to M2306.
  • Page 24 ® ABB Welcome Fig. 18 Function Building number (same as step 2). Select indoor station physical address. Select relay number of M2307. Select outdoor station number (floor number of outdoor station installed). Click “Add” to associate indoor station with relay.
  • Page 25 ® ABB Welcome Step 6: Save as one new project Fig. 20 Function Save as one new project: *.xml — 25 —...
  • Page 26 ® ABB Welcome Step 7: Import existing project data to new outdoor station, guard unit and lift control Fig. 21 Function Open one existing project: *.xml — 26 —...
  • Page 27 ® ABB Welcome...
  • Page 28 Any reproduction, disclosure to third parties or utilization of its contents - in whole or in parts - is forbidden without prior written consent of ABB Inc. © Copyright 2018 ABB. All rights reserved.