Setup reset

For setup reset send the SMS "90" to the controller. Combi Control responds with SETUP
report:
"Owner: All; Users: All; Pump: All; Ring 2,2,2; Param: 5, 24, 180".
This means Owner is not specified; all users can send commands;
the pump model is not specified, call commands are set to default;
"LOW TEMPERATURE" message will be sent when room temperature drops below 5 °C ,
"NO POWER" message blackout is in 24 hours and the "SERVICE" alarm message interval
is 180 days.
Setup SMS command you
Response SMS
send
90
SETUP
30
Controller function you activate
Setup reset (Owner deleted)
and controller restart

User setup

To set User numbers start your command SMS with "91", followed by the mobile phone
number of the User. For example: "91+495012345" or "915012345" to enter User1
number where "5012345" is the cell phone number of User1 and +49 is the country
code. User numbers (Owner, User1, User2) can be international (with the "+" symbol and
country code) or local. The length of the number must be between 3-16 symbols
("+" counts as one symbol). Multiple commands can be combined into one SMS. When a
User has been set, Combi Control responds with a SETUP report message.
Setup SMS command you send
91xx*
92xx*
93xx*
*xx marks the place of mobile phone number
Controller function you activate
User1 number entry (to delete: 910)
User2 number entry (to delete: 920)
Owner number entry (to delete: 930)
31