Add Special User Badge - Siemens SIPASS STANDALONE ACS3110 User Manual

Access control system
Table of Contents

Advertisement

Add Special User Badge

14
Add Special User Badge
Night Lock
Mode
Read
Open
Closed
Night lock
Add
Void
Program
16
Siemens Building Technologies
Fire Safety & Security Products
Special User Badges are granted access both, during Night Lock and during Nor-
mal Operation. Unlike the Night Lock Master, they have no effect on Night Lock
status.
Special User Badges must be added by using the Add Master while SiPass stand-
alone is in Night Lock mode.
Enter
Add Mode
Read
Open
Closed
Night lock
Add
Void
Program
Add Master
Schlüsselanhänge
r
Fig. 9
Add Special User Badge
Any SiPass 125 kHz badge can be added, except badges which are already in
memory as Special User Badges or Master.
Special User Badges can be voided the same way as normal badges (in Void
mode, regardless of the status of Night Lock).
Keep records of the ID numbers and functions of all badges. Lost tags can be
voided from memory by number, using an optional Remote Programmer.
See Appendix.
Add new
Special User
Badges
Read
Open
Closed
Night lock
Add
Void
Program
Add Master
Quit Add Mode,
resume
Night Lock Mode
Read
Open
Closed
Night lock
Add
Void
Program
02.2005