Siemens SINUMERIK 840D sl Operating Manual page 49

Hmi sl universal
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Resetting the actual value
NOTICE
Irreversible active work offset
The current active work offset is irreversibly deleted by this action.
Relative actual value
Note
The new actual value is only displayed. The relative actual value has no effect on the axis
positions and the active work offset.
The softkey is only available if the relevant machine data is set.
HMI sl Universal
Operating Manual, 01/2008, 6FC5398-6AP10-2BA0
Press the "Delete active WO" softkey.
The offset is deleted permanently.
1.
Press the "REL actual values" softkey.
2.
Enter the axis positions and press the "Input" key.
Machine manufacturer
Please also refer to the machine manufacturer's instructions.
Setting up the machine
2.4 Settings for the machine
49

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840de sl

Table of Contents