Panasonic M41A1G4L Operating Instructions Manual page 32

Compact ac geared motor
Table of Contents

Advertisement

Safety standard approved motor
EN Standard (to be considered when exporting motors to Europe)
It is a safety standard applied within the EU's borders, most part of which is based on the IEC standard. In
Europe, the power supply voltage is as high as single-phase 230 V and 3-phase 400 V and it is therefore
necessary to give consideration to electric shock in particular (Low Voltage Directive). In addition, because the
mechanical safety (Machinery Directive) is considered, there is a recognition that it is dangerous for a motor to
move suddenly as a result of automatic resetting of the protector etc. It is therefore required that, after the
occurrence of an abnormal condition activating the protector, the machine can be started only when manual
resetting is made by the operator. It is necessary to put a CE mark on products that have passed the test of the
EN standard and are to be exported and to show clearly their safety level. (The product level is specified in the
instruction manual. In Europe, when a (safety) self-declaration is required by a user, it should be submitted to the
user.) In the case of a motor with speed controller, it is necessary to show clearly the level of malfunction
(including malfunction of the motor and damage to other equipment) due to electromagnetic interference. (Check
the level individually.) This level is evaluated based on the motor and controller alone. Because electromagnetic
interference varies significantly depending on the wiring for incorporation into equipment, this level should be
regarded as a reference value and a final determination should be made after incorporation into equipment.
• EN standard on motor
Low Voltage Directive: Directive for 50 VAC to 1000 VAC equipment
EN60034 (rating of electric machine)
EN60664 (insulation coordination of equipment)
EN60204 (electric equipment of industrial machinery) : Provisions concerning industrial motor
Representative Wiring of Safety Standard Approved Motor
(1) The customer should verify conformance to the standards, laws, etc. on the completed equipment.
is an automatic reset type. To prevent hazardous unintentional restart, it must be
(2) The thermal protector
TP
wired as shown in the figure below.
(Connect a spark killer to the electromagnetic contactor.)
Do not connect the thermal protector
directly to the power source. Instead, connect it to the source through
TP
the switch SW A and SW B and relay
.
Ry
(3) Voltage of the thermal protector is the maximum rating AC250 V.
* Connection of the following is an example of the CW direction (clockwise) as viewed from the load side of the motor shaft.
• 70 mm sq. to 90 mm sq.
Wiring example of 4 pole induction motor and reversible motor.
SW B Relay (Ry)
SW A
Blue (P)
Ry
Blue (P)
Thermal
MCCB
Ry
White (U1)
protector
CW
Grey (U2)
Ry
Black (Z2)
CCW
Motor
Capacitor
• 70 mm sq. to 90 mm sq.
Wiring example of 4 pole single-phase motor with electromagnetic brake.
SW B
Relay (Ry)
SW A
Blue (P)
Ry
Blue (P)
Thermal
MCCB
protector
Ry
White (U1)
CW
Grey (U2)
Ry
Black (Z2)
CCW
Motor
Capacitor
Ry
Yellow
Electromagnetic
brake
Yellow
Ry
Panasonic Corporation Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
: Provisions concerning general items on motor
: Provisions concerning base items of motor insulation
• Wiring example of 2 pole induction motor
Relay (Ry)
Blue
SW A
SW B
Thermal
MCCB
White
protector
Ry
Brown
Grey
Black
Ry
Motor
• Wiring example of 2-pole, 4-pole 3-phase motor.
Connect between 3-phase power supply R and neutral point N.
SW B
Relay (Ry)
SW A
N
Blue (P)
Ry
Blue (P)
Thermal
MCCB
Ry
protector
Grey (V)
R
Ry
White (U)
S
Black (W)
T
Motor
Ry
– A-60 –
© Panasonic Corporation 2018 
AQCTB02E 201806-E
• Wiring example of 2-pole, 4-pole 3-phase motor.
(200 V/220 V/230 V)
SW B
Relay (Ry)
SW A
Blue (P)
Ry
Blue (P)
Thermal
MCCB
protector
Ry
Grey (V)
R
Ry
White (U)
S
Black (W)
T
Motor
Ry
• Wiring example of 4 pole 3-phase motor with electromagnetic brake.
(200 V/220 V/230 V)
SW B
Relay (Ry)
SW A
Blue (P)
Ry
Blue (P)
Thermal
MCCB
protector
Ry
Grey (V)
R
Ry
White (U)
S
Black (W)
T
Ry
Motor
Ry
Yellow
Electromagnetic
brake
Yellow
Ry
GB Standard (to be considered when exporting motors to China)
In the People's Republic of China, China Compulsory Certification (CCC) is applied to products affecting health
and safety of people, life and safety of animals and plants, environmental protection and public safety. Our motors
are subject to CCC (excluding some motors) and a CCC certification mark is put on the main body of a certified
motor.
• GB standard on motor
GB12350: Standard on safety of motor
GB25958: Standard on energy efficiency of motor
(For GB standard compliant products, please refer to the model list page of each breed.)
Export consideration
When export this product, follow statutory provisions of the destination country.
Panasonic Corporation Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
• Wiring example of 4 pole 3-phase motor with electromagnetic brake.
Connect between 3-phase power supply R and neutral point N.
SW B
Relay (Ry)
N
SW A
Blue (P)
Ry
Blue (P)
Thermal
MCCB
protector
Ry
Grey (V)
R
Ry
White (U)
S
Black (W)
T
Ry
Motor
Ry
Yellow
Electromagnetic
brake
Yellow
Ry
• When using the AC380 V/400 V 3-phase motor, please connect to
be applied voltage to AC250 V from AC100 V between the lines of
thermal protector (blue blue).
– A-61 –
© Panasonic Corporation 2018 
AQCTB02E 201806-E

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents