Philips InnoSpire Go Instructions Manual page 8

Mesh nebulizer system
Hide thumbs Also See for InnoSpire Go:
Table of Contents

Advertisement

Available languages

Available languages

Cumulative drug deposition – Salbutamol
100.0
90.0
80.0
70.0
60.0
50.0
40.0
30.0
20.0
10.0
0.0
0.1
1
10
Upper aerodynamic diameter (µm)
Performance information provided as required by EN 13544-1:2007 may not apply for medications in
suspension or high viscosity form. In such cases information should be sought from the medication supplier.
Performance may vary based on atmospheric pressure depending on altitude above sea level, barometric
pressure, and temperature.
Nebulizer performances are based upon testing that utilizes adult ventilatory patterns and are likely to be
different from those stated for pediatric (2 years and older) populations.
Electromagnetic information: The InnoSpire Go needs special precautions regarding EMC and needs to be
installed and put into service according to the EMC information provided in this document.
Portable and mobile RF communications equipment can affect medical electrical equipment.
The CE mark on the product denotes compliance with all applicable EU Directives. Note that the Notified Body
number does not apply to the RoHS (restriction of the use of certain hazardous substances in electrical and
electronic equipment) Directive.
Expected service life: Nebulizer handset, battery and mask adapter, 3 years from date of purchase
Mouthpiece assembly, 1 year from date of first use
Masks, 1 year from date of first use
14
100
Symbol glossary
l
ON (power)
O
OFF (power)
Serial number
Follow instructions for use
Complies with RTCA/DO-160F
section 21, category M
IP22
Ingress Protection rating
Warranty
Respironics, Inc warrants the nebulizer handset and battery to be free from defects in materials and
workmanship under normal use and operation for a period of 2 years from date of purchase from
Respironics, Inc. The warranty is limited to repair or replacement, at Respironics, Inc's sole option, of any
such component or equipment claimed to be defective when claim is shown to be bona fide by evaluation
by Respironics, Inc. This warranty does not extend to any components or equipment subjected to misuse,
improper operation, accidental damage, or unauthorized repairs, and is not extended to charges of, or
for, labor repairs. All items returned must be properly packaged and shipped, prepaid, by the product
distributor servicing the unit. Respironics, Inc shall not be liable to purchaser or others for loss of use of
equipment or for indirect, or incidental or consequential damages that might arise.
Class II internally powered
CAUTION
device, double insulated
Alternating current
Type BF applied parts
Temperature limitation
Separate collection
Atmospheric pressure
Humidity
Manufacturer
Date of manufacture