PCA LEOs
Figure 2-6 shows the locations of the six LEDs on the
HP-FL PCA.
The self-test
LED will go on for about five seconds during the self-test and then it must go off.
If it remains on, or goes back on, the
PCA
is defective. Replace it.
If the self-test passes, the remaining LEDs indicate the link status. Table 2-2
shows common patterns that may occur after a successful self-test. (The "A"
LED blinks irregularly and somewhat slowly, 10 to 60 time per minute.) For
more information on self-test and LED interpretation, see chapter 3.
Table 2-2. Common LED Patterns After Self-Test Passes.
LED (color)
Pattern
Link Status
Self-test (red) off
C (red)
off
S (red)
off
The
HP-FL
device adapter and link are
R (red)
off
operational.
P (green)
onlblinking
A (green)
blinking
Self-test (red) off
Bad connection to the remote device:
S (red)
onlblinking
- the cable is not connected,
R (red)
on
- there is no power to the remote device, or
P (green)
on
- the remote device is faulty.
Self-test (red) off
The
HP-FL
is not generating ID requests (replace
P (green)
onlblinking
the
PCA)
A (green)
off
Self-test (red) off
Bad connection to remote device:
S (red)
on
the cable ends are reversed.
R (red)
on
Self-test (red) off
The
PCA
jumper J2 is in the "M" position
C (red)
on
(remove the
PCA
and place the jumper in the "L"
P (green)
onlblinking position), or the disk drive is incompatible.