Mitsubishi Electric MELSEC iQ-R Series User Manual page 49

Cc-link ie field network waterproof/dustproof remote i/o module (with safety functions)
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Combination of double inputs
The safety remote I/O module evaluates the logic of input signals and reflects the results to safety remote inputs (SA\X).
When the double input signals differ, the double input discrepancy detection state is applied. The following tables list the
correspondence between each double input signal state and safety remote input (SA\X).
■Combination of double inputs (NC/NC)
Input terminal state
Safety remote input
(SA\X0 to SA\XB)
*1
*1
Xn
Xn+1
SA\Xm
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
ON
ON
*1 n: Even number from 0 to A
*2 m: Safety device address (even number from 0 to A) assigned to the master station
*3 After the double input discrepancy time has elapsed, the status changes to the listed status.
■Combination of double inputs (NC/NO)
Input terminal state
Safety remote input
(SA\X0 to SA\XB)
*1
*1
Xn
Xn+1
SA\Xm
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
ON
ON
OFF
*1 n: Even number from 0 to A
*2 m: Safety device address (even number from 0 to A) assigned to the master station
*3 After the double input discrepancy time has elapsed, the status changes to the listed status.
■States of safety remote inputs (SA\X0, SA\X1) for X0 and X1 (double wiring (NC/NC))
Input terminal status: X0
Input terminal status: X1
SA\X0
SA\X1
(1) Even when the input terminal X0 turns on, SA\X0 does not turn on because X1 is off.
(2) When the double inputs are on (X0 and X1 are on), SA\X0 and SA\X1 turn on.
Even when SA\X0 and SA\X1 are off, the time when X0 and X1 are in double input discrepancy state is measured and if the measured time exceeds a set
detection time, a double input discrepancy detection error occurs.
Safety input status
(SA\XC to SA\X17)
*2
SA\Xm+
SA\XC+
SA\XC+
*2
*2
1
m
m+1
OFF
ON
ON
*3
OFF
OFF
OFF
*3
OFF
OFF
OFF
ON
ON
ON
Safety input status
(SA\XC to SA\X17)
*2
SA\Xm+
SA\XC+
SA\XC+
*2
*2
1
m
m+1
ON
OFF
OFF
ON
ON
ON
OFF
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
(1)
OFF
I/O LED status
*1
*1
Xn
Xn+1
*2
Off
Off
*3
*3
*3
Red
Red
*3
*3
*3
Red
Red
Green
Green
I/O LED status
*1
*1
Xn
Xn+1
*2
*3
*3
Red
Red
Off
Green
Green
Off
*3
*3
Red
Red
Double input
discrepancy state
ON
ON
ON
(2)
ON
Evaluation result of double inputs
OFF (Normal)
OFF (Discrepancy)
OFF (Discrepancy)
ON (Normal)
Evaluation result of double inputs
OFF (Discrepancy)
OFF (Normal)
ON (Normal)
ON (Discrepancy)
7 FUNCTIONS
7.1 Input Function
7
47

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nz2gfs12a2-14dtNz2gfs12a2-16dte

Table of Contents