GE MDS SD Series Technical Manual page 54

Secure, long range ip/ethernet & serial
Hide thumbs Also See for MDS SD Series:
Table of Contents

Advertisement

46
RSPSupply - 1-888-532-2706 - www.RSPSupply.com
http://www.RSPSupply.com/p-8461-MDS-UP-SD9-MS2ES-Upgrade-Key-SD9-MS-to-SD9-ES.aspx
disruption of the wireless network. The TX time-out is cleared
when the keying source goes away and the radio keys again.The
default selection is
ON
reached).
TX Time-Out Delay (sec)
transmitter is taken offline. The default time-out setting is 30 sec-
onds.
—Determines whether or not the radio is configured to
Datakey
key (transmit) upon receipt of payload data at its interface port.
The default setting is
—Determines whether or not the radio is configured to
RTS Key
key (transmit) upon receipt of an RTS (ready to send) signal at its
interface port. The default setting is
Push-To-Talk Delay (ms)
after a keying event, which must expire before the radio is
allowed to transmit. The allowable range is 0 to 255 ms, with the
default being 0.
Clear-To-Send Delay (ms)
between when an RTS (ready-to-send) signal is received and
when the CTS (clear-to-send) signal is returned. The allowable
range is 0 to 255 ms, and the default is 0.
Automatic Freq. Correction
(AFC), is used to counteract the slight RF frequency drift that
may occur over time or through wide swings of ambient temper-
ature.
Switched Carrier (B Modems)
for use on radios with "B" modem suffixes, and only applies to
remote radios. ("B" modems are intended for compatibility with
earlier MDS x710 radios.) In some networks, the master unit is
not keyed continuously, and transmits only when it has data to
send to remotes. This is known as Switched Carrier operation. In
such a network, the remote radios should have the Switched Car-
rier setting turned
. The default setting is
ON
—This setting is intended for use in very
RX Signal Attenuation
strong signal environments (-20dbm or stronger). It should be
kept off when working with normal or weak signal levels.
SD Series Technical Manual
(transmitter shuts down when time limit is
—Sets the time delay, after which a keyed
.
ON
.
ON
—Allows programming a brief time delay
—Allows programming a brief time delay
—Automatic Frequency Correction
—The Switched Carrier setting is only
OFF
MDS 05-4846A01, Rev. D
.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mds sd2Mds sd4Mds sd9