ABB ACS800 Hardware Manual page 115

1.5 to 2000 kw inverter modules
Hide thumbs Also See for ACS800:
Table of Contents

Advertisement

Inverter module/
Frame
unit type
size
ACS800-104-0260-5
1×R8i
ACS800-104-0320-5
1×R8i
ACS800-104-0400-5
1×R8i
ACS800-104-0460-5
1×R8i
ACS800-104-0610-5
1×R8i
ACS800-104-0910-5
2×R8i
ACS800-104-1210-5
2×R8i
ACS800-104-1820-5
3×R8i
ACS800-104-2430-5
4×R8i
U
= 690 V
N
ACS800-104-0011-7
R4i
ACS800-104-0016-7
R4i
ACS800-104-0020-7
R4i
ACS800-104-0025-7
R4i
ACS800-104-0030-7
R4i
ACS800-104-0040-7
R4i
ACS800-104-0050-7
R5i
ACS800-104-0060-7
R5i
ACS800-104-0070-7
R6i
ACS800-104-0100-7
R7i
ACS800-104-0120-7
R7i
ACS800-104-0210-7
1×R8i
ACS800-104-0260-7
1×R8i
ACS800-104-0320-7
1×R8i
ACS800-104-0400-7
1×R8i
ACS800-104-0440-7
1×R8i
ACS800-104-0580-7
1×R8i
ACS800-104-0870-7
2×R8i
ACS800-104-1160-7
2×R8i
ACS800-104-1740-7
3×R8i
ACS800-104-2320-7
4×R8i
Nominal air
Power loss
flow
3
3
W (Btu/h)
m
/h (ft
/min)
3300 (11300)
1280 (750)
3900 (13300)
1280 (750)
4700 (16100)
1280 (750)
5700 (19500)
1280 (750)
7700 (26300)
1280 (750)
11300 (38600)
2560 (1510)
14900 (50900)
2560 (1510)
22000 (75100)
3840 (2260) 1440 (225)
28900 (98700)
5120 (3010) 1920 (295)
300 (1030)
103 (61)
340 (1160)
103 (61)
440 (1500)
103 (61)
530 (1810)
103 (61)
610 (2080)
103 (61)
690 (2360)
103 (61)
840 (2870)
168 (99)
1010 (3450)
168 (99)
1100 (3760)
480 (283)
1500 (5120)
480 (283)
1800 (6150)
480 (283)
3300 (11300)
1280 (750)
4000 (13700)
1280 (750)
4600 (15700)
1280 (750)
5200 (17800)
1280 (750)
6800 (23200)
1280 (750)
7400 (25300)
1280 (750)
12900 (44100)
2560 (1510)
14400 (49200)
2560 (1510)
21300 (72800)
3840 (2260) 1440 (225)
28100 (96000)
5120 (3010) 1920 (295)
Minimum effective area
Minimum effective area
of air inlet
with
unfiltered
Luftfilter/
unfiltered
airTex G150
2
2
2
2
cm
(in
)
cm
(in
)
cm
575 (90)
1150 (180)
920 (140)
575 (90)
1150 (180)
920 (140)
575 (90)
1150 (180)
920 (140)
575 (90)
1150 (180)
920 (140)
575 (90)
1150 (180)
920 (140)
960 (150)
1920 (295)
1536 (240)
960 (150)
1920 (295)
1536 (240)
2880 (445)
2304 (355)
3840 (595)
3072 (475)
300 (47)
600 (93)
300 (47)
600 (93)
300 (47)
600 (93)
300 (47)
600 (93)
300 (47)
600 (93)
300 (47)
600 (93)
400 (62)
800 (124)
400 (62)
800 (124)
325 (50)
650 (101)
325 (50)
650 (101)
325 (50)
650 (101)
575 (90)
1150 (180)
920 (140)
575 (90)
1150 (180)
920 (140)
575 (90)
1150 (180)
920 (140)
575 (90)
1150 (180)
920 (140)
575 (90)
1150 (180)
920 (140)
575 (90)
1150 (180)
920 (140)
960 (150)
1920 (295)
1536 (240)
960 (150)
1920 (295)
1536 (240)
2880 (445)
2304 (355)
3840 (595)
3072 (475)
Max. pressure
of air outlet
with
nominal air
Luftfilter/
airTex G150
2
2
2
2
(in
)
cm
(in
)
1840 (290)
1840 (290)
1840 (290)
1840 (290)
1840 (290)
3072 (475)
3072 (475)
4608 (715)
6144 (950)
480 (74)
960 (149)
480 (74)
960 (149)
480 (74)
960 (149)
480 (74)
960 (149)
480 (74)
960 (149)
480 (74)
960 (149)
640 (99)
1280 (198)
640 (99)
1280 (198)
520 (81)
1040 (161)
520 (81)
1040 (161)
520 (81)
1040 (161)
1840 (290)
1840 (290)
1840 (290)
1840 (290)
1840 (290)
1840 (290)
3072 (475)
3072 (475)
4608 (715)
6144 (950)
Technical data
115
drop of
cabinet at
flow
Pa
150
150
150
150
150
180
180
180
180
12
12
12
12
12
12
17
17
67
67
67
150
150
150
150
150
150
180
180
180
180