Installation checklist

Checklist

Check the mechanical and electrical installation of the drive before start-up. Go
through the checklist below together with another person.
Check
MECHANICAL INSTALLATION
The ambient operating conditions are allowed. (See
The unit is properly fastened on a non-flammable base. (See
separate document ACS 800 MultiDrive Modules; Planning the Cabinet Installation
[3AFE 64783531, English])
The cooling air is able to flow freely.
The motor and the driven equipment are ready for start. (See
connection, and separate document ACS 800 MultiDrive; Planning the Electrical Installation
[3AFE 64783742, English])
ELECTRICAL INSTALLATION (See
MultiDrive Modules; Planning the Cabinet Installation [3AFE 64783531, English])
The capacitors are reformed if stored over one year (refer to ACS 600/800 Capacitor
Reforming Guide [64059629, English]).
The module is grounded properly.
The input voltage matches the nominal input voltage of the module.
The power connections at UDC+ and UDC– and their tightening torques are OK.
Appropriate DC fuses are installed.
The motor connections at U2, V2 and W2 and their tightening torques are OK.
The motor cable is routed away from other cables.
There are no power factor compensation capacitors in the motor cable.
The external control connections to the inverter unit are OK.
There are no tools, foreign objects or dust from drilling inside the module or cubicle.
All shrouds and covers are in place.
R8i modules with Prevention of unexpected start option only: The voltage selection jumper on
the AGPS board is correctly set (230 or 115 V).
The Prevention of unexpected start circuit is completed (See
Electrical
installation, and separate document ACS 800
Technical
data.)
Cabinet
construction, and
Technical
data:
Electrical
installation).