Bosch ICP-CC404 Quick Reference Manual
Hide thumbs Also See for ICP-CC404:

Advertisement

ICP-CC404
Quick Reference Guide
ICP-CC404
EN
Control Panel

Advertisement

Table of Contents
loading

Summary of Contents for Bosch ICP-CC404

  • Page 1 ICP-CC404 Quick Reference Guide ICP-CC404 Control Panel...
  • Page 2 ICP-CC404 | Quick Reference Guide | Copyright Notice Copyright Notice Notice of Liability Unless otherwise indicated, this publication is the While every precaution has been taken in the preparation of this document, neither Bosch Security copyright of Bosch Security Systems, Inc. (“Bosch”).
  • Page 3: Table Of Contents

    ICP-CC404 | Quick Reference Guide | Contents Figures Contents Figure 1: RE012/E: 2-Channel Keyfob Transmitter14 Introduction ............4 Figure 2: RE013/E: 4-Channel Keyfob Transmitter14 Programming ............4 Figure 3: Split EOL Wiring Diagram ......15 Programming Using a Codepad .......4 Figure 4: Split EOL Wiring Diagrams Using N/O Programming Option Bits .........4...
  • Page 4: 1.0 Introduction

    ICP-CC404 | Quick Reference Guide | 1.0 Introduction To change the data programmed in the current 1.0 Introduction location, enter the new value (0 to 15) and press [*]. Thank you for choosing the ICP-CC404 Control The codepad indicators show the new value. For Panel for your installation.
  • Page 5: Installer's Programming Commands

    ICP-CC404 | Quick Reference Guide | 3.0 Using the System Table 3: Codepad Indicators Data Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 MAINS Value Indicator Indicator Indicator Indicator Indicator Indicator Indicator...
  • Page 6: Code To Isolate

    4. Press the RF keyfob until hearing two beeps. The Enter the Installer Code and press [8 #] keys (for RF keyfob is added. Refer to the ICP-CC404 example, [1 2 3 4 8 #]). Installation Guide for more details.
  • Page 7: Program Stay Mode 2 Zones

    ICP-CC404 | Quick Reference Guide | 3.0 Using the System 3.14 Program STAY Mode 2 Zones 3.19 Test Report 1. Enter the Installer Code or Master Code and Press and hold [9] until two beeps sound. press [4 #] (for example, [1 2 3 4 4 #]).
  • Page 8: 4.0 Programming Parameters

    ICP-CC404 | Quick Reference Guide | 4.0 Programming Parameters 4.0 Programming Parameters Location Options/Notes Default Function 000 to 015 0 = 10 and telephone termination = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0...
  • Page 9 ICP-CC404 | Quick Reference Guide | 4.0 Programming Parameters Location Options/Notes Default Function 1 Set DTMF dialing pulses to 1 digit/sec 2 Reserved Dialer Options 3 4 Change decadic dialing to 60/40 8 Reserved 1 Upload/download allowed 2 Call back phone number required for upload/download...
  • Page 10 ICP-CC404 | Quick Reference Guide | 4.0 Programming Parameters Location Options/Notes Default Function The fifth location of the zone definition is the Zone Options 2 parameter. The options are: 267 to 322 1 Isolated in STAY Mode 1 Forced arming allowed...
  • Page 11 ICP-CC404 | Quick Reference Guide | 4.0 Programming Parameters Location Options/Notes Default Function Location 346: tens digit 346 to 347 Location 347: units digit System Status – AUX Power Supply Fail Restore Report Location 348: tens digit 348 to 349 Location 349: units digit System Status –...
  • Page 12 ICP-CC404 | Quick Reference Guide | 4.0 Programming Parameters Location Options/Notes Default Function System fault Chime 368 to 397 Outputs Fire alarm (resetting) Zone not sealed (continued) Fire alarm (latching) Zone not sealed after Exit Time Fire alarm (verification) Reserved...
  • Page 13 ICP-CC404 | Quick Reference Guide | 4.0 Programming Parameters Location Options/Notes Default Function Location 398: increments of 1 sec (0 to 15 sec) 398 to 399 Location 399: increments of 16 sec (0 to 240 sec) Entry Time 1 Location 400: increments of 1 sec (0 to 15 sec)
  • Page 14: Two-Channel And Four-Channel Keyfobs14

    ICP-CC404 | Quick Reference Guide | 5.0 Two-Channel and Four-Channel Keyfobs Location Options/Notes Default Function 1 Radio receiver (WE800) 2 Latching keyswitch input Radio Input Options 3 Momentary keyswitch input 4 Reserved 748 to 749 Reserved Location 750: Country Code (tens digit)
  • Page 15: 6.0 Wiring Diagrams

    ICP-CC404 | Quick Reference Guide | 6.0 Wiring Diagrams 6.0 Wiring Diagrams Figure 3: Split EOL Wiring Diagram 1 – Zone 1 5 – Zone 7 2 – Zone 2 6 – Zone 8 3 – Zone 6 7 – Zone 4 4 –...
  • Page 16: Icp-Cc404 Wiring Diagram

    ICP-CC404 | Quick Reference Guide | 6.0 Wiring Diagrams Figure 6: ICP-CC404 Wiring Diagram 1 – 605 plug 7 – Power to external equipment: 15 – Strobe 12 V @ 400 mA 2 – 6 (Red) Telecom line (street) 16 – Horn speaker 5 (Yellow) Internal phone line 8 –...
  • Page 17: Icp-Cc404 Component Overlay

    ICP-CC404 | Quick Reference Guide | 6.0 Wiring Diagrams Figure 7: ICP-CC404 Component Overlay 1 – Socket for telecom lead connect 6 – Battery input 2 – Termination for phone line 7 – Plug pack input (Bosch TF008) OUT – internal phone line 8 –...
  • Page 18: We800/E Wireless On/Off Interface

    1 – Direct link cable 5 – Black 2 – Receiver interface connection 6 – Termination for phone line 3 – Wireless On/Off Interface 7 – Socket for telecom lead connection 4 – Red Bosch Security Systems, Inc. | 10/08 | F01U089402-01...
  • Page 19: Country Codes

    ICP-CC404 | Quick Reference Guide | 7.0 Country Codes 7.0 Country Codes The PSTN provides a programmable line interface to meet international telephone line requirements. This program meets various country PTT standards. Country Code Country Code Country Code Country Code...
  • Page 20 ICP-CC404 | Quick Reference Guide | 7.0 Country Codes Country Code Country Code Country Code Country Code Country Code New Zealand Bahrain El Salvador Nepal Nigeria French Equatorial Gui Nicaragua Polynesia Norway Iceland Eritrea Niger Peru Israel Ethiopia Palau Philippines...
  • Page 21 ICP-CC404 | Quick Reference Guide | Notes Notes Bosch Security Systems, Inc. | 10/08 | F01U089402-01...
  • Page 22 ICP-CC404 | Quick Reference Guide | Notes Notes Bosch Security Systems, Inc. | 10/08 | F01U089402-01...
  • Page 23 ICP-CC404 | Quick Reference Guide | Notes Notes Bosch Security Systems, Inc. | 10/08 | F01U089402-01...
  • Page 24 Bosch Security Systems, Inc. Bosch Security Systems, Inc. 130 Perinton Parkway 130 Perinton Parkway Fairport, NY 14450-9199 USA Fairport, NY 14450-9199 USA www.boschsecurity.com www.boschsecurity.com © 2008 Bosch Security Systems, Inc. F01U089402-01...

Table of Contents