3.14
Program STAY Mode 2 Zones
1. Enter the Installer Code or Master Code and
press [4 #] (for example, [1 2 3 4 4 #]).
2. Enter the zone number to automatically isolate,
and press [*].
3. Repeat Step 2 to program other zones.
4. Press [#] to exit.
3.15
Fault Analysis
1. Press and hold [5] until two beeps sound.
2. The zone indicators show the fault condition.
Refer to Table 6 on page 7.
3. Press [#] to exit.
Table 6: Fault Condition Indicators
Zone LED
FAULT Condition
1
Battery low
2
Date/time reset
3
Sensor watch fail
4
Horn speaker fail
5
Telephone line fail
6
EEPROM fail
7
AUX Power Supply fail
8
Communication fail
3.16
Modem Call (Alarm Link)
Press and hold [6] until two beeps sound.
3.17
Reset Latching Outputs
Press and hold [7] until two beeps sound.
3.18
Set the Codepad ID/Buzzer Tone
1. Press and hold [8] until the desired buzzer tone
sounds.
2. Press [#] to exit.
Bosch Security Systems, Inc. | 10/08 | F01U089402-01
ICP-CC404 | Quick Reference Guide | 3.0
3.19
Test Report
Press and hold [9] until two beeps sound.
3.20
Speaker Test
Press and hold [1] until two beeps sound.
The speaker sounds for 2 sec.
3.21
Bell Test
Press and hold [2] until two beeps sound.
The piezo siren sounds for 2 sec.
3.22
Strobe Test (Toggle On/Off)
1. To turn the strobe on, press and hold [3] until
three beeps sound.
2. To turn the strobe off, press and hold [3] until
two beeps sound.
3.23
Telco Arm Sequence (Call Forward
On)
1. Enter the Installer Code or Master Code and
press [3 #] (for example, [1 2 3 4 3 #]).
2. Enter [1 #].
3. Enter the Call Forward On sequence.
4. Press [#] to exit.
3.24
Telco Disarm Sequence (Call
Forward Off)
1. Enter the Installer Code or Master Code and
press [3 #] (for example, [1 2 3 4 3 #]).
2. Enter [2 #].
3. Enter the Call Forward Off sequence.
4. Press [#] to exit.
Using the System
7