Error
Error definition and causes
code
1167H
Unsent data found, but could not be sent.
1802H
During data link, overlapping IP addresses
have been detected.
1811H
A stop error has been detected in the CPU
module.
1830H
Number of reception requests of transient
transmission (link dedicated instruction)
exceeded the upper limit of simultaneously
processable requests.
20E0H
The module cannot communicate with the
CPU module.
2160H
IP address duplication was detected.
2220H
The parameter setting is corrupted.
2221H
The set value is out of the range.
24C0H
An error was detected on the system bus.
to
24C3H
24C6H
An error was detected on the system bus.
3009H
The result when the value set in
"Communication Period Interval Setting" in
"Communication Period Setting" under
"Basic Settings" of the master station is
multiplied by "Communication Period
Setting" of the slave station set in "Network
Configuration Settings" under "Basic
Settings" is out of the range.
300AH
The set value that is set in the master
station is out of the range.
300BH
The Announce frame send cycle
parameter error was detected.
3 TROUBLESHOOTING
70
3.5 List of Error Codes
Action
• Check the settings for connection with the external device.
• Check the operation of the external device or switching hub.
• Since there may be congestion of packets on the line, send data after a
certain period of time.
• Check if the connection cable is disconnected.
• Check that there is no connection failure with the switching hub.
• Execute the communication test, and if the test was completed with an
error, take corrective action.
Change the IP address of devices with a duplicated IP address.
Check the error of the CPU module and take action using the module
diagnostics of the engineering tool.
Lower the transient transmission usage frequency, and retry the operation.
The hardware failure of the CPU module may have been occurred. Please
consult your local Mitsubishi representative.
Check and correct the IP addresses.
Check the detailed information of the error by executing module diagnostics
using the engineering tool, and write the displayed parameter. If the same
error occurs again, the possible cause is a hardware failure of the module.
Please consult your local Mitsubishi representative.
Check the detailed information of the error by executing module diagnostics
using the engineering tool, and correct the parameter setting corresponding
to the displayed parameter No..
• Take measures to reduce noise.
• Reset the CPU module, and run it again. If the same error occurs again
even after taking the above, the possible cause is a hardware failure of the
module, base unit, or extension cable. Please consult your local Mitsubishi
representative.
• Take measures to reduce noise.
• Reset the CPU module, and run it again. If the same error occurs again
even after taking the above, the possible cause is a hardware failure of the
module, base unit, or extension cable. Please consult your local Mitsubishi
representative.
Check the detailed information on module diagnostics of the engineering tool
and set the value of "Communication Period Setting" of the slave station
under "Basic Settings" within 16ms.
• Check the detailed information of the error by executing module
diagnostics using the engineering tool, and correct the parameter setting of
the master station corresponding to the displayed parameter No..
• If the same error occurs again, the possible cause is a hardware failure of
the module. Please consult your local Mitsubishi representative.
• Check the Announce frame send cycle parameter setting value of the
device operating as the grandmaster. When the Motion module is
operating as the grandmaster, reset the CPU module, and run it again.
• If the same error occurs again even after taking the above measure, the
possible cause is a hardware failure of the module. Please consult your
local Mitsubishi representative.
Detailed
information
Operation source
information
• IP address
Parameter
information
• Parameter type
Parameter
information
• Parameter type
• I/O No.
• Parameter No.
• Network No.
• Station No.
System configuration
information
• I/O No.
• Base No.
• Slot No.
• CPU No.
Parameter
information
• Parameter type
• I/O No.
• Parameter No.
• Network No.
• Station No.

Advertisement

Table of Contents
loading

Table of Contents