Siemens SIMATIC IPC847C Getting Started
Hide thumbs Also See for SIMATIC IPC847C:

Advertisement

SIMATIC IPC847C

SIMATIC
Industrial PC
SIMATIC IPC847C
Getting Started
06/2011
A5E02669190-03

___________________
Introduction
___________________
Description
___________________
Application planning
___________________
Installing
___________________
Connection
___________________
Commissioning
___________________
Troubleshooting
___________________
Dimension drawings
___________________
Appendix
1
2
3
4
5
6
7
8
A

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC IPC847C

  • Page 1 ___________________ SIMATIC IPC847C Introduction ___________________ Description ___________________ Application planning SIMATIC ___________________ Installing Industrial PC ___________________ SIMATIC IPC847C Connection ___________________ Commissioning Getting Started ___________________ Troubleshooting ___________________ Dimension drawings ___________________ Appendix 06/2011 A5E02669190-03...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Troubleshooting RAID........................29 Dimension drawings ..........................30 Dimensional drawing of the device ....................30 Dimensional drawing for the use of telescopic rails..............31 Appendix..............................32 Guidelines and declarations......................32 Certificates and Approvals ......................33 Service and support ........................34 Index................................ 35 SIMATIC IPC847C Getting Started, 06/2011, A5E02669190-03...
  • Page 4: Introduction

    The operating instructions provide useful information on many topics such as the hardware expansion options, modification of the system configuration and technical data. Conventions The term "rack PC" or "device" is sometimes used to refer to the SIMATIC IPC847C product in this documentation. The abbreviation "CP" stands for CP 1616 onboard. Note...
  • Page 5: Description

    Rear view of the device (example) Item Description ① Rear drive cooling fan ② Modules of the redundant power supply (optional) ③ Expansion slots ④ Connection elements ⑤ Mains connection of the redundant power supply modules SIMATIC IPC847C Getting Started, 06/2011, A5E02669190-03...
  • Page 6: Operator Controls

    Used to connect the device to the mains. Depending on the "After Power Failure" BIOS setting, the PC may turn on automatically. Otherwise, you may have to operate the on/off ① button on the front. SIMATIC IPC847C Getting Started, 06/2011, A5E02669190-03...
  • Page 7: Connecting Elements

    ④ Acknowledgement button of the redundant power supply The acoustic error signal is deactivated when the button is pressed. Connecting elements Interfaces Layout of the interfaces on the rear of the device SIMATIC IPC847C Getting Started, 06/2011, A5E02669190-03...
  • Page 8 Display port connection of the DP adapter at Dual Head graphics card (optional) ⑮ Connecting Connection for equipotential bonding potentials For unique labeling, the LAN interfaces are numbered on the enclosure. The numbering by the operating system may deviate from this. SIMATIC IPC847C Getting Started, 06/2011, A5E02669190-03...
  • Page 9 The permitted voltage range is 100 to 240 V AC. ⑯ Power connection socket in case of redundant power supply of the device. The permitted voltage range is 100 to 240 V AC. SIMATIC IPC847C Getting Started, 06/2011, A5E02669190-03...
  • Page 10: Status Displays

    No data traffic  GREEN Data traffic PN Ι MPI/DP Display of the No connection  (optional) communication status No data traffic  to S7 or PROFIBUS PROFIBUS not equipped  GREEN MPI/DP data traffic  SIMATIC IPC847C Getting Started, 06/2011, A5E02669190-03...
  • Page 11 Error in early BIOS All lit CPU startup failure Post Error in early POST For unique labeling, the LAN interfaces are numbered on the enclosure. The numbering by the operating system may deviate from this. SIMATIC IPC847C Getting Started, 06/2011, A5E02669190-03...
  • Page 12 The two "virtual" CP 1616 LEDs are only visible in the SIMATIC software and can be read via SNMP. PROFINET Virtual LEDs CP is active STOP CP is in the stop state Flashes The states "flashes slowly" or "flashes rapidly" do not exist. SIMATIC IPC847C Getting Started, 06/2011, A5E02669190-03...
  • Page 13: Application Planning

    ● Verify that the shipment contains the complete unit and your separately ordered accessories. Please inform your local dealer of any disagreements or transport damage. ● Please inform Siemens AG by means of the enclosed SIMATIC IPC/PG quality control report form.
  • Page 14 Order no. 6AGA114-1 ... Microsoft Windows Product Key Ethernet 1 address Ethernet 2 address CP 1616 onboard layer 2 Device equipment Information on the device equipment is available on the inside of the front door. SIMATIC IPC847C Getting Started, 06/2011, A5E02669190-03...
  • Page 15: Ambient And Environmental Conditions

    Protect the device from unauthorized access with a front door that can be locked and is adequately secured. CAUTION Electrostatic-sensitive devices The device contains electronic components which may be destroyed by electrostatic charge. Before you open the front door, read the (ESD) guidelines for handling electrostatic- sensitive devices. SIMATIC IPC847C Getting Started, 06/2011, A5E02669190-03...
  • Page 16: Installing

    ● Tower installation: a tower kit can be ordered separately for this (not available in some countries) ● Mounting on telescopic rails When telescopic rails are used for mounting, the device can be withdrawn fully from the cabinet or rack. SIMATIC IPC847C Getting Started, 06/2011, A5E02669190-03...
  • Page 17: Technical Data Of The Telescopic Rails

    Technical data of the telescopic rails Ultimate load per pair At least 23 kg Full extraction length At least 470 mm Rail thickness Maximum 9.7 mm Mounting screws M5 x 6 mm SIMATIC IPC847C Getting Started, 06/2011, A5E02669190-03...
  • Page 18: Connection

     The computer in question must be turned off and the power supply connector should be plugged in.  During the measurement, all cables from the plant to the computer should be connected.  All other components in the plant must be active. SIMATIC IPC847C Getting Started, 06/2011, A5E02669190-03...
  • Page 19: Connecting The Power Supply

    SIMATIC PCs with a PFC circuit. UPS characteristics are described and classified in the standards EN 50091-3 and IEC 62040-3. Devices with sinusoidal output voltage in the normal and buffered mode are identified with the classification "VFI-SS-.." or "VI-SS-..". SIMATIC IPC847C Getting Started, 06/2011, A5E02669190-03...
  • Page 20 Connect the power cable to the socket Plug the power cable plug into the power outlet. ② Turn on the ON/OFF switch The yellow power LED (standby) on the front panel of the PC lights up. SIMATIC IPC847C Getting Started, 06/2011, A5E02669190-03...
  • Page 21 You cancel the ④ warning signal by pressing button The status is also displayed and signaled by the SIMATIC monitoring software, if active. You can mute the acoustic alarm in the SIMATIC monitoring software. SIMATIC IPC847C Getting Started, 06/2011, A5E02669190-03...
  • Page 22: Equipotential Bonding

    One cable tie (not included in the package) is required for each interface. To fix the strain relief, you will need a TORX T10 screwdriver. Steps for mounting the strain relief Remove the PROFINET interface plate. SIMATIC IPC847C Getting Started, 06/2011, A5E02669190-03...
  • Page 23 Connection 5.4 Strain relief for network cables Steps for mounting the strain relief Attach the PROFINET strain relief. Attach the cable using the cable tie. SIMATIC IPC847C Getting Started, 06/2011, A5E02669190-03...
  • Page 24: Commissioning

    The operating safety of the device and the plant is at risk. Do not switch off the device during the entire installation process. Do not change the default values in the BIOS setup. SIMATIC IPC847C Getting Started, 06/2011, A5E02669190-03...
  • Page 25 The product key is located on the "Certificate of Authentication", in the "Product Key" line. Result The interface of the operating system is displayed every time you turn on the device and after the startup routine. SIMATIC IPC847C Getting Started, 06/2011, A5E02669190-03...
  • Page 26: Reinstalling The Software

    Operating system with installed hardware drivers and monitoring software, e.g. DiagBase. Note Place the data carrier from which the operating system is to be booted later at the first position in the boot folder. Carry out this setting in the BIOS Setup. SIMATIC IPC847C Getting Started, 06/2011, A5E02669190-03...
  • Page 27: Troubleshooting

    If you use an adapter or extension for the mouse  cable, also check these connectors. If the mouse pointer still does not appear on the screen after you have performed these checks and actions, contact your technical support team. SIMATIC IPC847C Getting Started, 06/2011, A5E02669190-03...
  • Page 28 5. In the following "Install Windows" dialog, click on "Repair your computer" or press the <R> key. The "System Recovery Options" dialog appears. The system is checked for errors. 6. Next, click "Repair and restart" SIMATIC IPC847C Getting Started, 06/2011, A5E02669190-03...
  • Page 29: Troubleshooting Raid

    BIOS Activate UEFI boot in the BIOS setup.  setup The boot data carrier is  set up with GPT and UEFI boot is deactivated in the BIOS setup SIMATIC IPC847C Getting Started, 06/2011, A5E02669190-03...
  • Page 30: Dimension Drawings

    Dimension drawings Dimensional drawing of the device SIEMENS POWER ETHERNET 1 ETHERNET 2 PROFIBUS/MPI WATCHDOG TEMP HDD1 ALARM HDD2 ALARM Figure 8-1 Dimensional drawing SIMATIC IPC847C Getting Started, 06/2011, A5E02669190-03...
  • Page 31: Dimensional Drawing For The Use Of Telescopic Rails

    Dimension drawings 8.2 Dimensional drawing for the use of telescopic rails Dimensional drawing for the use of telescopic rails Figure 8-2 Dimensional drawing for the use of telescopic rails SIMATIC IPC847C Getting Started, 06/2011, A5E02669190-03...
  • Page 32: Appendix

    The installation guidelines and safety instructions given in this documentation have to be noted during commissioning and operation. Connecting I/Os Noise immunity requirements to EN 61000-6-2 are met if connected I/Os are suitable for industrial applications. Peripheral devices are only be connected via shielded cables. SIMATIC IPC847C Getting Started, 06/2011, A5E02669190-03...
  • Page 33: Certificates And Approvals

    A.2 Certificates and Approvals Certificates and Approvals ISO 9001 certificate The Siemens quality management system for all production processes (development, production and sales) meets ISO 9001:2000 requirements. This has been certified by DQS (the German society for the certification of quality management systems).
  • Page 34: Service And Support

    ● Installed additional software Tools & downloads Please check regularly if updates and hotfixes are available for download to your device. The downloads are available on the Internet under "After Sales Information System SIMATIC PC/PG" (see above). SIMATIC IPC847C Getting Started, 06/2011, A5E02669190-03...
  • Page 35: Index

    Monitoring Status displays, 10, 12 Mounting holes, 17 Fan, 5 FAN, 11 Filter mat, 5 Front door, 5 On/off button, 5, 6 Front view, 5 Operating system, 24 Initial commissioning, 24 Order no., 14 SIMATIC IPC847C Getting Started, 06/2011, A5E02669190-03...
  • Page 36 Ethernet, 10 FAN, 11 PROFIBUS/MPI, 10 TEMP, 11 WATCHDOG, 11 Strain relief Ethernet cable, 22 Supply voltage, 20 Telescopic rails Mounting methods, 17 TEMP, 11 Troubleshooting, 29 USB interface, 5 Ventilation slots, 15 WATCHDOG, 11 SIMATIC IPC847C Getting Started, 06/2011, A5E02669190-03...