Download Print this page
Haier HP200M3 Installation And Service Manual

Haier HP200M3 Installation And Service Manual

Heat pump water heater

Advertisement

Heat Pump Water Heater
Installation and Service Manual
Model
HP200M3
HP250M3
HP250M3C
Please read this manual carefully prior to your use of this water heater.
The appearance of the water heater given in this manual is for reference only.

Advertisement

loading

Summary of Contents for Haier HP200M3

  • Page 1 Heat Pump Water Heater Installation and Service Manual Model HP200M3 HP250M3 HP250M3C Please read this manual carefully prior to your use of this water heater. The appearance of the water heater given in this manual is for reference only.
  • Page 2: Table Of Contents

    Contents 1. Product safety statement......................3 2. Functionings & principles ....................4 3. Technical parameters ......................5 4. Description of parts and components ................. 6 5. Installation introduction ......................11 6. Operating and settings......................22 7. Faults and protection ....................... 25 8.
  • Page 3: Product Safety Statement

    1. Product safety statement 1. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Page 4: Functionings & Principles

    2. Functionings & principles A low-pressure liquid refrigerant is vaporized in the heat pump's evaporator and passed into the compressor. As the pressure of the refrigerant increases, so does its temperature. The heated refrigerant runs through a condenser coil within the storage tank, transferring heat to the water stored there.
  • Page 5: Technical Parameters

    600*629*1987 mm 600*629*1987 mm Packing dimension without pallet 736*695*1810 mm 736*695*2120 mm 736*695*2120 mm Packing dimension with pallet 736*695*1940 mm 736*695*2250 mm 736*695*2250 mm Net/Gross weight 91/103kg 102/115kg 119/132kg * The COP and noise level data was tested in Haier lab...
  • Page 6: Description Of Parts And Components

    4. Description of parts and components Heat pump structure(HP200M3/HP250M3)...
  • Page 7 Heat pump structure(HP250M3C)...
  • Page 8 Exploded view Heat pump system components 1. Compressor The compressor is to effect a low-temperature low-pressure evaporator refrigerant vapor sucked and compressed into high temperature and pressure of the superheated vapor, and then discharged to the condenser heat exchanger. Exhaust pipe Intake pipe Wiring box...
  • Page 9 2. Evaporator Evaporator effects: it makes the liquid refrigerant absorbs heat and is evaporated into steam. 3. Condenser A condenser: high-temperature high-pressure refrigerant vapor is condensed into liquid, during condensation, the refrigerant vapor discharge heat, the heat is absorbed by the heating medium. 4.
  • Page 10 6. High Voltage Switchgear High-voltage switch is to prevent excessive pressure in the system, thus affecting the life of the system components, high-pressure of the high-voltage switch is 2.8MPa. 7. Service valve Service valve is mainly used for filling refrigerant, after removing the nuts, it contains a valve needle, sales staff can vacuum infusion refrigerant from here.
  • Page 11: Installation Introduction

    9. Refrigerant Heat pump refrigerant is R134a, ODP value is 0, no damage to the ozone layer. R134a refrigerant cans appearance is as follows: 5. Installation introduction a. Installation precaution - Do not install the water heater in the position where exposed to gas, vapours or dust. - Install the appliance on a flat, solid surface.
  • Page 12 from 10 to 35° C. Keep an adequate distance between the working heat-pump and the resting places. b. Installation dimensions (mm)
  • Page 13 c.Installation angle refer to the following diagrams Pipe connection...
  • Page 14 - Remove vent grid first. - Install diameter 180mm duct. - Pressure drops from duct must be lower than or equal to the static pressure of the fan. - If the pressure drops out of range, the performance of the appliance will be impaired. Maximum length of the air connection 5m (Diameter of air connection 160 mm).
  • Page 15 Habitable room or outside air (with two ducts): -Can obtain free heat from the garage. -If the outside air temperature is low, connection to the outside air may lead to overconsumption of electricity. -Referring installer menu, adjust the fan speed Installation caution When making the connections, you should respect the standards and local directives.
  • Page 16 of the appliance. Do not connect the domestic hot water connection directly to copper pipes in order to prevent galvanic couples in iron/copper (risk of corrosion). It is compulsory to fit the domestic hot water connection with a dielectric connection (not supplied). - Pressure relief valve, thermostatic valve, stop valve, check valve, T&P valve and French combination valve are not included in the accessories, please select proper fittings in local market;...
  • Page 17 Connection to solar collectors (Version HP250M3C) WARING: Plumber -Be Aware Using solar energy, please make sure that the heat pump water tank temperature not more than 85 ℃.
  • Page 18 f. Connection to gas boiler (Version HP250M3C)
  • Page 19 WARING: Plumber -Be Aware Using boiler auxiliary heating, please make sure that the heat pump water tank temperature not more than 85 ℃. Electrical connections precautions WARNING - Only qualified professionals may carry out electrical connections, always with the power off. - The earthing shall comply with local standards.
  • Page 20 socket shall not be less than 1.8 m, and it shall be ensured that water would not be splashed on these places. The socket shall be installed out of children’s reach. - The phase line, zero line and ground line inside a power socket used in your home shall be wired correctly without any wrong positioning or false connection, and internal short circuit shall be avoided.
  • Page 21 Boiler signal line 2*0.75mm2 - Connect the boiler back-up connector (boiler back-up).refer to the boiler instruction manual. - Referring installer menu, adjust the parameters i. Wiring diagram...
  • Page 22 6. Operation and functions Display Functions: Electrical leakage protection The control system of this machine features an electricity leakage protection function. 10-minutes protection When starting the machine immediately after electricity input, the fan and the compressor will start at the same time. When starting the machine immediately after shutdown, the system goes into the protection mode and starts after 10 minutes, which is considered to be normal.
  • Page 23 Description of the pictograms...
  • Page 24 Installer settings - To open the installer settings, press switch off the system, then press at the same time for 10 seconds. - When menu is open, press to change the value of the settings. - Press to confirm the settings. - Press to close the menu.
  • Page 25 7. Checking and maintenance - Installation and maintenance of the appliance must be done by a qualified professional . - Before working on the appliance, Shut down the machine and cut off the power supply . - Do not touch with wet hands. - Maintenance operations are important to guarantee optimum performance and extend the life of the equipment.
  • Page 26: Faults And Protection

    8. Faults and protection...
  • Page 27 Fault code identification method:...
  • Page 31 Temperature sensor resistance measurement method Temperature sensor resistance measurement method (method of measuring the resistance value of the compressor of the same, but is switched to the small resistance of the interface unit). Multimeter set to Ohms, according to the picture of the method of measuring the resistance of the temperature sensor.
  • Page 32 Check the compressor line is through the current transformer Check the signal cable is short-circuited Press the yellow button to switch to the picture, when a short circuit, there is a beep, the resistance is zero. Check the tank heater for leaks Press the yellow button to switch to the picture shown, turn the heating power measurements, if leakage resistance is zero, if not leak, show resistance.
  • Page 33: The Method Of Dismantling Products

    Check that the power cord L, N lines are in the same order into the leakage protection coil 9. The method of dismantling products Make sure the power cord is disconnected. 1、 Remove the Display 2、 Remove the Cover Use a screwdriver to remove the two screws Use a screwdriver to...
  • Page 34 3、 Remove the Air channel and fan 2. remove the 1. remove the Air channel - up 3. remove the Air channel – down 4、 Remove the Magnesium rod Off the power and close the inlet valve, open any outlet valve, exhaust pressure, when no water flows out of time,turn off all the valves.
  • Page 35 6、 Open the control box Use a screwdriver to remove the 4 screws Controller panel...
  • Page 36 Ambient temperature sensor(yellow) Exhaust temperature sensor(white) Intake sensor 1(red) Evaporator sensor (white) Tank temperature sensor(red) Solar or boiler sensor Leakage protection coil Municipal low power Display panel switching signal 7、 Remove Electric heater ①Remove Front cover - down After the Cover is removed, use a screwdriver to remove the bottom two screws of the Front cover –...
  • Page 37 Use a screwdriver to remove the 2 screws ③Remove the internal wiring and electric heater Use a screwdriver to remove the 6 screws. After the tank has been emptied, with a socket wrench to remove the electric heater. 10. The method of Charge of the refrigerant gas 1.
  • Page 38 Service valve connect the Service valve manometer connect the refrigerant cylinder Connect the vacuum pump 3. Making the vacuum & Gas Charging: Bleeding from the circuit should take place with a vacuum pump and pressure gauge assembly suitable for R134a. Make sure the vacuum pump is full of oil up to the level indicated by the oil gauge.
  • Page 39 Heat pump manometer pressure gauge Service valve hose refrigerant cylinder vacuum pump Electronic vacuum pump scales...
  • Page 40: Repairs Common Tools

    10. Repairs common tools Tools Name Quantity Illustration Spanner Hexagon Spanner Flathead screwdriver Phillips screwdriver Needle-nose pliers Measuring tape Pressure gauge Vacuum pump Electronic scale Bending device...

This manual is also suitable for:

Hp250m3Hp250m3c