1MRS755551 B
WGA631
Installation and commissioning manual
Table 10:
Enclosure
Description
Electrostatic discharge test, class IV
For contact discharge
For air discharge (without LED)
Radio frequency interference tests
Conducted, common mode
Radiated, amplitude-modulated
Table 11:
Ethernet and WGA port
Description
Fast transient disturbance tests, class III
Radio frequency interference tests
Conducted, common mode
CE approval
Table 12:
Standard tests
Mechanical tests
Vibration tests (sinusoidal)
Table 13:
Power consumption
Description
Running
Technical data
Value
According to IEC 61000-4-2
+/- 8 kV
+/- 8 kV
According to IEC 61000-4-6
10 V (rms), f = 150 kHz...80 MHz
According to IEC 61000-4-3
10 V/m (rms), f = 80...3000 MHz
Value
According to IEC 61000-4-4
2 kV
According to IEC 61000-4-6 and IEC 60255-22-6
10 V (rms), f = 150 kHz...80 MHz
Complies with the EMC directive 89/336/EEC and
the LV directive 73/23/EEC
According to DNV
Value
~ 5 W