en | ULC Installation Guide
Off-board cellular passive communication system - detailed
wiring G Series
BATTERY STATUS
Off: Normal
On: Missing
Quick Flash: Low
Slow Flash:
Charging
Low 12.1 VDC
Load Shed 10.2 VDC
Figure 1.14: B9512G/B8512G* control panel with a B44x (cellular)
module connected through a B450 module
NOTES: *B9512G-E/B8512G-E control panels are supported in
the configuration shown. In this configuration, the control panel
can also connect to up to 2 B430 modules. In this configuration,
the control panel also supports IP (B9512G-E/B8512G-E control
panels require a B426 module, supervised). AC input is required
(not shown).
2019.06 | 02 | F.01U.321.698
Minimum system requirements for Classification in accordance with ANSI/SIA
CP-01-2010. UL Listed and Classified control unit Model B9512G and B8512G.
Do not connect
UL Listed and Classified keypad Model B942, B930, B925F, B926F, B921C,
to a receptacle
B920, B915, D1255RB, D1256RB and D1257RB. UL Listed Local Bell.
controlled by
a switch.
The equipment should be installed in accordance with the NFPA 70 (National Electrical
Code) and NFPA 72 (National Fire Alarm Code).
1
CLASS 2
Depending on the application, the installation may need to be in accordance with one or
more of the following UL standards: UL681, UL1076, UL1641 and C22.1, CEC, Part 1.
16.5 VAC 40 VA 60 Hz
Use of a D185 is not suitable for remote station protected premises service where separate
2
TRANSFORMER
transmissions circuits are required for fire, supervisory (when applicable) and trouble
signals.
All external connections except Terminal 5 (BATTERY(+) are inherently power limited.
3
+ AUX POWER
Requirements for battery standby time might reduce allowable output.
POWER SUPPLY REQUIREMENTS
4
BATTERY (
-
)
The Power Supply provides a maximum of 1.4 Amps for the Control Panel and all Accessory Devices. For System Loading,
refer to the B9512G/B8512G UL Listing Document, ULLD. Auxiliary powered devices: 11.8 to 12.5 VDC
Battery: Replace every 3 to
The B9512G/B8512G Control Panel is UL Listed For CS, RS, L, AUX, Prop and Res Fire and Res, Prop,
5
BATTERY ( + )
5 years with one or two
Cent. Stat, Local, and PS Con. Merc. Burg, MSV, BSV, Holdup, suitable as a dual line trans. sys.
Model D126 or D1218 12V
Signaling means: DAC, Cell or IP
Lead Acid Batteries.
OUTPUT
6
A (1)
The system is intended to be checked by a Qualified Technician at least every 3 years. The types of initiating circuits the control
panel has been approved for are A, M, WF, SS. The types of signaling the control panel has been approved for are DAC, OT, NC,
OUTPUT
RevPol.
7
B (2)
Refer to the system wiring diagrams in the B9512G/B8512G
WARNING!
To prevent risk of shock,
ULLD and to the D125B Installation Instructions for compatible
OUTPUT
8
disconnect AC power and
smoke detectors. 2-wire Compatible Identifier "A". Printed
C (3)
communication lines before
information describing proper installation, operation, testing,
servicing.
maintenance, repair service and response to an alarm is to be
9
COMMON
ON-BOARD POINTS
10
EARTH GROUND
WARNING!
WARNING!
Multi-Battery
Incorrect wiring will
installation requires
damage this
Model D122 or D122L
equipment.
Point 1
Point 2
Dual Battery Harness.
Devices powered by
Improper installation
any output must be
11
12
can be a fire hazard .
supervised.
B
USB POWER
A
STATUS
L
S
I
E
N
K
T
POINT 1 COM POINT 2 POINT 3 COM POINT 4
USB
ETHERNET
provided with this equipment.
WARNING!
Owner Instructions (P/N F.01U.307.371): Not to
be removed by anyone except occupant.
Voltage Ranges: Open 3.7 - 5.0 VDC, Short 0.0 - 1.3 VDC, Normal 2.0 - 3.0 VDC
1 k
End-of-line-Resistors Required (P/N 15093130-004), Max Loop Current: 5 mA
Point 3
Point 4
Point 5 Point 6
Point 7 Point 8
13
14
15
16
17
18
19
20
21
POINT 5 COM POINT 6 POINT 7 COM POINT 8
SIM
B44x
Antenna
B450
MOD-2
MODULE RELEASE
MOD-1
PWR+/R
30
29
A/Y
28
B/G
27
COM/B
PWR+/R
26
A/Y
25
B/G
24
COM/B
23
22
ZONEX
TMPR
RESET
ZONEX
TMPR
B915/B915I/B920)
Bosch Security Systems B.V.
Control Panels
Keypad
(models

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents