INSTALLING PUMP KIT
4
REMOVE EXISTING DRAIN TUBE
Remove the existing drain tube. The drain tube
is the white tube with a white snap fit clamp on it
in the upper left hand corner of the side service
panel access area. Save the snap fit clamp. It
will be used to install the new drain tube.
Side View of Unit
5
INSTALL THE PUMP KIT
A. Uncoil the 10-foot long discharge tubing
(clear). Push one end completely onto the
barbed discharge elbow of the pump and
securely fasten it with the small metal hose
clamp. Use pliers to open the hose clamp.
Discharge
tubing
B. Route the other end of the discharge tubing
through the routing panel in the back of the
unit. Put the end of the discharge tube into a
drain.
Discharge tubing
31-1000385 Rev. 0
Installation Instructions
Snap Fit Clamp
Existing Drain Tube
Hose clamp
Discharge
elbow
Side of the unit
(Continued)
5
INSTALL THE PUMP KIT (Cont.)
C. Place the pump over the bolts located on the
base of the ice machine and secure with the
two nuts and washers provided in the kit.
Pump drain
discharge tubing
D. Route the straight portion of drain tube
through the hole in switch assembly bracket.
E. Connect drain tube to pump inlet and secure
with the white snap fit clamp from the kit.
F. Connect the pressure switch hose to the
drain tube.
Drain tube
G. Mount the switch assembly bracket to the
base using two provided sheet metal screws
and lock washers.
Sheet metal
screws & lock
washers
Nut & Washer
Bolts
Side view of unit.
Drain tube
Switch
assembly
bracket
Snap fit
clamp
Pump
inlet
Switch
assembly
bracket
Pressure
switch hose