3 WIRING

3.1 Terminal connection diagram
Source logic
Main circuit terminal
Control circuit terminal
Three-phase AC
power supply
*2. To supply power to the
control circuit separately,
remove the jumper across
R1/L11 and S1/L21.
Control input signals (No voltage input allowed)
Terminal functions vary with
the input terminal
assignment (Pr. 178 to Pr. 189)
(Refer to the Instruction
Manual (Applied))
holding selection
Multi-speed
selection
*3.JOG terminal can be used
as pulse train input terminal.
Use Pr. 291 to select
JOG/pulse.
Second function selection
*4. AU terminal can be
used as PTC input
terminal.
Terminal 4 input selection
(Current input selection)
Selection of automatic restart
after instantaneous
Contact input common
(Common for external power supply transistor)
Frequency setting signal (Analog)
Frequency setting
potentiometer
1/2W1k 
*6
* 5. Terminal input specifications
can be changed by analog
input specifications
Auxiliary
switchover (Pr. 73, Pr. 267).
Set the voltage/current input
switch in the OFF position to
Terminal
select voltage input (0 to 5V/0
4 input
to10V) and ON to select
(Current
current input (4 to 20mA).
(Refer to the Instruction
Manual (Applied))
*6 . It is recommended to use 2W1k
when the frequency setting signal
is changed frequently.
CAUTION
·
To prevent a malfunction due to noise, keep the signal cables more than 10cm away from the power cables. Also separate the main circuit wire of the
input side and the output side.
·
After wiring, wire offcuts must not be left in the inverter.
Wire offcuts can cause an alarm, failure or malfunction. Always keep the inverter clean.
When drilling mounting holes in an enclosure etc., take care not to allow chips and other foreign matter to enter the inverter.
·
Set the voltage/current input switch correctly. Different setting may cause a fault, failure or malfunction.
*1. DC reactor (FR-HEL)
Be sure to connect the DC
reactor supplied.
MC
MCCB
R/L1
S/L2
T/L3
Jumper
*2
R1/L11
S1/L21
Earth
(Ground)
Forward
STF
rotation
start
STR
Reverse
rotation
start
STOP
Start self-
RH
High speed
RM
Middle
speed
RL
Low speed
JOG
Jog operation
RT
MRS
Output stop
RES
Reset
AU
CS
power failure
SD
PC
24VDC power supply
10E(+10V)
10(+5V)
3
2
2
5
1
(+)
1
input
(-)
(+)
4
(-)
input)
Connector
for plug-in option
connection
*1
Earth
(Ground)
P1
P/+
Inrush
current
limit
circuit
T
Main circuit
Control circuit
*3
*4
AU
PTC
24V
PU
connector
Voltage/current
*5
input switch
4 2
ON
OFF
0 to 5VDC
(Initial value)
0 to 10VDC
selectable
*5
0 to 20mADC
(Analog common)
0 to ± 10VDC
(Initial value)
selectable
0 to ± 5VDC
*5
4 to 20mADC
(Initial value)
0 to 5VDC
*5
selectable
0 to 10VDC
Option connector 1
Option connector 2
Option connector 3
Terminating
resistor
Terminal connection diagram
N/-
U
V
IM
W
Relay output
C1
Terminal functions
B1
Relay output 1
vary with the output
(Fault output)
terminal assignment
A1
(Pr. 195, Pr. 196)
(Refer to the
Instruction Manual
C2
(Applied))
B2
Relay output 2
A2
Open collector output
RUN
Running
Terminal functions
SU
vary with the output
Up to frequency
terminal assignment
IPF
Instantaneous
(Pr. 190 to Pr. 194)
power failure
(Refer to the
OL
Instruction Manual
Overload
(Applied))
FU
Frequency detection
SE
Open collector output common
Sink / source common
(+)
CA
Analog current output
(0 to 20mADC)
(-)
(+)
AM
Analog signal output
(0 to 10VDC)
5
(-)
RS-485 terminals
TXD+
Data transmission
TXD-
RXD+
Data reception
RXD-
SG
GND
VCC
(Permissible load
5V
current 100mA)
Motor
Earth (Ground)
8