6 PARAMETER LIST

6.1 Parameter list
For simple variable-speed operation of the inverter, the initial setting of the parameters may be used as they are. Set the
necessary parameters to meet the load and operational specifications. Parameter setting, change and check are available
from the operation panel (FR-DU07).
REMARKS
 
indicates simple mode parameters. (initially set to extended mode)
The shaded parameters in the table allow its setting to be changed during operation even if "0" (initial value) is set in Pr. 77 Parameter write
selection.
Parameter
Name
0
Torque boost
Maximum frequency
1
Minimum frequency
2
Base frequency
3
Multi-speed setting (high
4
speed)
Multi-speed setting (middle
5
speed)
Multi-speed setting (low
6
speed)
Acceleration time
7
Deceleration time
8
Electronic thermal O/L relay
9
DC injection brake operation
10
frequency
DC injection brake operation
11
time
DC injection brake operation
12
voltage
13
Starting frequency
14
Load pattern selection
15
Jog frequency
Jog acceleration/
16
deceleration time
17
MRS input selection
High speed maximum
18
frequency
19
Base frequency voltage
Acceleration/deceleration
20
reference frequency
Acceleration/deceleration
21
time increments
Stall prevention operation
22
level (torque limit level )
Stall prevention operation
23
level compensation factor at
double speed
Multi-speed setting (4 speed
24 to 27
to 7 speed)
Multi-speed input
28
compensation selection
Acceleration/deceleration
29
pattern selection
31
Frequency jump 1A
32
Frequency jump 1B
33
Frequency jump 2A
Setting
Initial
Range
Value
1
0 to 30%
%
60
0 to 120Hz
Hz
0 to 120Hz
0Hz
0 to 400Hz
60Hz
0 to 400Hz
60Hz
0 to 400Hz
30Hz
0 to 400Hz
10Hz
0 to 3600/360s
15s
0 to 3600/360s
15s
Rated
0 to 3600A
inverter
current
0 to 120Hz,
3Hz
9999
0 to 10s, 8888
0.5s
0 to 30%
1%
0 to 60Hz
0.5Hz
0 to 5
0
0 to 400Hz
5Hz
0 to 3600/360s
0.5s
0, 2, 4
0
120 to 400Hz
60Hz
0 to 1000V,
9999
8888, 9999
1 to 400Hz
60Hz
0, 1
0
0 to 400%
150%
0 to 200%,
9999
9999
0 to 400Hz,
9999
9999
0, 1
0
0 to 5
0
0 to 400Hz,
9999
9999
0 to 400Hz,
9999
9999
0 to 400Hz,
9999
9999
Parameter
Name
34
Frequency jump 2B
35
Frequency jump 3A
36
Frequency jump 3B
37
Speed display
41
Up-to-frequency sensitivity
42
Output frequency detection
Output frequency detection
43
for reverse rotation
Second acceleration/
44
deceleration time
45
Second deceleration time
46
Second torque boost
47
Second V/F (base frequency)
Second stall prevention
48
operation current
Second stall prevention
49
operation frequency
Second output frequency
50
detection
Second electronic thermal
51
O/L relay
DU/PU main display data
52
selection
CA terminal function
54
selection
Frequency monitoring
55
reference
Current monitoring
56
reference
57
Restart coasting time
58
Restart cushion time
59
Remote function selection
Energy saving control
60
selection
61
Reference current
Reference value at
62
acceleration
PARAMETER LIST
Setting
Initial
Range
Value
0 to 400Hz,
9999
9999
0 to 400Hz,
9999
9999
0 to 400Hz,
9999
9999
0, 1 to 9998
0
0 to 100%
10%
0 to 400Hz
6Hz
0 to 400Hz,
9999
9999
5s
0 to 3600/360s
0 to 3600/
9999
360s, 9999
9999
0 to 30%, 9999
0 to 400Hz,
9999
9999
0 to 220%
150%
0 to 400Hz,
0Hz
9999
30Hz
0 to 400Hz
0 to 3600A,
9999
9999
0, 5 to 8,
10 to 14,
17 to 20,
22 to 25,
0
32 to 35, 39,
46, 50 to 57,
100
1 to 3, 5 to 8,
10 to 14, 17,
1
18, 21, 24,
32 to 34, 46,
50, 52, 53, 70
Hz
0 to 400Hz
60
Rated
0 to 3600A
inverter
current
0, 0.1 to 30s,
9999
9999
1s
0 to 60s
0, 1, 2, 3
0
0, 4
0
0 to 3600A,
9999
9999
0 to 220%,
9999
9999
18