Operating Modes; Commissioning Notes; Parameter List; Parameter Setting - Siemens RDJ100 Programming Instructions Manual

Room thermostat with 24-hour time switch and large lcd. programmable, for heating systems
Table of Contents

Advertisement

Operating modes

The device has the following modes: Automatic, Comfort, Energy saving and Frost
protection.
Move the operating mode slider to the respective position to select another operating mode.
Automatic mode
Comfort mode
Energy saving
mode
Frost protection

Commissioning notes

Parameter list

Parameter
P01
P02
P03
End

Parameter setting

The parameter setting remains in non-volatile memory and is not erased when the battery is
removed. The reset function on the rear of the thermostat reloads the factory settings.
4
Siemens
Building Technologies
Automatic mode is active when symbol
operates as the selected 24-hour time program.
Comfort mode is active when symbol
controls to the temperature setpoint adjusted at
be adjusted by setting the program slider to
Energy saving mode is active when symbol
controls to the temperature setpoint adjusted at
be readjusted by setting the program slider to
Frost protection is active when symbol
controls to the preset temperature setpoint for frost protection.
Description
Factory setting
Control behavior PID slow (4)
30 °C
Maximum
temperature
range
5 °C
Minimum
temperature
range
Exit parameter
setting
Datasheet
is displayed. The device
is displayed. The device
. This setpoint can
.
is displayed. The device
. This setpoint can
.
is displayed. The device
Setting range
Remark
0 = 2P, 1.0 K
1 = 2P, 0.5 K
2 = PID fast
4 = PID slow
P03...30 °C
Limit of comfort
and economy
setpoint
5 °C...P02
Limit of comfort
and economy
setpoint
A6V10954415_en--_e
2018-11-20

Hide quick links: