DOK-INDRV*-FCS01******-IT01-EN-P
Rexroth IndraDrive Fc Drive Controllers Frequency Converters FCS01
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
Mounting without additional lateral space between the frequency
converters is allowed. The mounting position is vertical.
A
≥ 100 mm
Fig.3-12:
Vertical Mounting Position
Warm air must be dissipated above the devices!
If several frequency converters are arranged above one another, make sure
that the top limit of the air intake temperature is not exceeded. If the limit is
exceeded, we recommend that you mount an "obstacle" (e.g., a cable duct)
between the frequency converters which will interrupt the direct air flow (ris‐
ing warm air).
Efficiency: For installation in a control cabinet, ensure sufficient ventilation.
During operation, dissipation heat is approx. 5% (depending on the device
size and equipment) of the nominal power of the frequency converter.