▶ Connect the pump's power cable to the green connector block on the
terminal strip [2].
1 1
Fig. 59 Connection of pump
6.14

Connecting to the mains

DANGER: Danger of fatal accident due to electric shock.
▶ Disconnect the boiler from the mains power supply
before working on the boiler. Guard against
unintentional re-connection.
All Worcester boilers require a permanent live.
A mains supply of 230 V - 50 Hz is required.
External controls are suitable for volt free installation (or 230V via the
relay supplied with the 50-V2 and 65-V2 boilers).
Wiring to the boiler must be in accordance with the current I.E.E.
(BS 7671) Wiring Regulations and any local regulations.
Wiring should be a 3 core PVC insulated cable, not less than 0.75 mm²
(24 x 0.2mm), and to table 16 of BS 6500.
Connection must be made in a way that allows complete isolation of the
electrical supply such as a double pole switch having 3 mm contact
separation in both poles, or by a three pin connector, serving only the
boiler and system controls. This boiler is equipped with a double pole
switch [1]. The means of isolation must be accessible to the user after
installation.
The electrical connection to the mains supply should be readily
accessible and adjacent to the boiler.
If the supply cord is damaged, it must be replaced by a qualified
electrician to avoid a hazard and must be an original spare part.
The electrical supply for both the boiler and the system must be taken
from the same fused spur outlet.
6720814332 (2018/04)
N
PE
L
2
6 720 807 034-020.1TD
ON
OFF
1
Fig. 60 Mains supply
[1]
Switch
7

Operating the boiler

1
2
3
4
5
Fig. 61 Control panel
[1]
On/off switch
[2]
Reset key
[3]
Chimney sweep key
[4]
Help key
[5]
Display
[6]
Menu key
[7]
Down key
[8]
Up key
[9]
Diagnostic plug
[10] Burner LED
The front of the boiler contains a control panel with the following
elements:
On/off switch
The boiler can be switched on or off via the on/off switch. The power
supply is not interrupted.
c
Reset
key
The boiler can be restarted via the
faults ( Chapter 12.2 "Reset").
d
Chimney sweep
key
The boiler can be brought into operation via the
out measurements. Used for servicing.
Operating the boiler
6720648726-59.2TD
10
6 7
8
9
6720813419-4.1TD
c
key in the event of interlocking
d
key in order to carry