Connections - ABB Tina 10A Original Instructions Manual

Adaptor unit
Hide thumbs Also See for Tina 10A:
Table of Contents

Advertisement

3

Connections

FMI-1B
Focus Receiver connector:
8-pole M12 female, Tina 10A/B/C
1 ) White: +24 VDC
2 ) Brown: +24 VDC
3 ) Green: -
4 ) Yellow: -
5 ) Grey:
OSSD1
6 ) Pink:
OSSD2
7 ) Blue:
0 VDC
8 ) Red:
LMS
NB: Shielded cable is recommended between this unit and the rest of the safety circuits.
Caution! All cable colours according to ABB/Jokab Safety standard cables.
Warning!
The information channel output shall never be used for the safety purpose(s).
The OSSD connections shall not be used for purposes other than intended. All loading or tampering with loops can
lead to serious risk of life.
2TLC172145M0201, rev. A
2011-09-23
Focus Receiver
Focus Transmitter
Vital / Pluto
Vital / Pluto connector:
M12 5-pole male, Tina 10A/B/C
1 ) Brown: +24 VDC
2 ) White: Dynamic signal input
3 ) Blue:
0 VDC
4 ) Black:
Dynamic signal output
5 ) Grey:
Information
FMI-1B connector:
M12 5-pole female, Tina 10B
1 ) Brown: +24 VDC
2 ) White: Power "OFF"
3 ) Blue:
Reset lamp
4 ) Black:
Test / Reset 1
5 ) Grey:
Muting lamp
6
M12 5-pole male
seen from cable
M12 5-pole female
seen from cable
M12 8-pole male
seen from cable
M12 8-pole female
seen from cable
Focus Transmitter connector:
M12 5-pole female, Tina 10C
1 ) Brown: +24 VDC
2 ) White: -
3 ) Blue:
0 VDC
4 ) Black:
-
5 ) Grey:
-