ABB Tina 10B Product Manual
ABB Tina 10B Product Manual

ABB Tina 10B Product Manual

Adapter unit
Hide thumbs Also See for Tina 10B:

Advertisement

Quick Links

SA F E T Y PR OD U CTS
Tina 10A/B/C Adapter unit
Product Manual
2TLC010042M0201 Rev.C
ORIGINAL INSTRUCTIONS
new.abb.com/low-voltage/products/safety-products

Advertisement

Table of Contents
loading

Summary of Contents for ABB Tina 10B

  • Page 1 — SA F E T Y PR OD U CTS Tina 10A/B/C Adapter unit Product Manual 2TLC010042M0201 Rev.C ORIGINAL INSTRUCTIONS new.abb.com/low-voltage/products/safety-products...
  • Page 2 Suitability for use ABB shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer’s application or use of the product. Third party certificates for the products are available at https://new.abb.com/low- voltage/products/safety-products.
  • Page 3: Table Of Contents

    Table of Contents 1 Introduction ..........................4 Purpose of document ........................ 4 Intended audience ........................4 Reading prerequisites ........................ 4 Special notes ..........................4 2 Safety ............................5 Safety precautions ........................5 3 Product description........................6 4 Installation........................... 7 Installation precautions ......................7 Testing safety functions ......................
  • Page 4: Introduction

    This document is intended for authorized personnel. Reading prerequisites It is assumed that the reader of this document has knowledge of the following: • Basic knowledge of ABB safety products • Knowledge of machine safety Special notes Pay attention to special notes in the document:...
  • Page 5: Safety

    Safety Safety precautions The safety precautions must be followed during installation, operation, maintenance and troubleshooting. It is the responsibility of the user to ensure the correct overall functionality. Warning! Carefully read through the entire product manual before using the device. Warning! The devices shall be installed by authorized personnel following applicable Safety regulations, standards and the Machinery directive.
  • Page 6: Product Description

    DYNlink safety circuit monitored by a safety controller or a safety PLC. Tina 10A, Tina 10B and Tina 10C are used to adapt light beams and light curtains with OSSD outputs to the DYNlink safety circuit. This also enables complete external interconnections using cables with M12 connectors only, which reduces the cabling to and connections in the apparatus enclosure.
  • Page 7: Installation

    Installation • Attach the cable or device to the M12 connector on Tina. • Gently hold the Tina unit to the mounting surface and attach the unit using an M4 bolt. • See max. tightening torques in chapter “Technical data”. Installation precautions Warning! All safety functions shall be tested before starting up the system.
  • Page 8: Connections

    C) Orion Receiver A) Smile D) Orion Transmitter B) Safety controller/Safety PLC C) Orion Receiver A) Smile M12 8-pole female, Tina 10 A/B/C M12 5-pole female, Tina 10B White Tina 10A/10C: +24 VDC Brown +24 VDC Tina 10B: Test/Reset White...
  • Page 9 ABB web. Note! Which cable to use between Orion and Tina 10A/B/C is depending on Orion model used – see product catalog on ABB web. Warning! Information output signals shall never be used for safety purpose(s). Warning! The OSSD connections shall not be used for purposes other than intended.
  • Page 10: Connection Examples

    Connection examples Tina 10C Caution! All cable colors according to ABB standard cables. 2TLC010042M0201 Rev.C...
  • Page 11: Functions

    Functions LED Indications LED indication Description DYNlink state Green Safety inputs ON (protection OK) DYNlink signal Green/red flashing Safety inputs ON (protection OK) 0 VDC, DYNlink interrupted before this unit Safety input OFF 0 VDC or DYNlink signal Safety inputs at any state +24 VDC connected to DYNlink signal input (pin-2) or interrupted in this unit...
  • Page 12: Maintenance

    Warning! The safety functions and the mechanics shall be tested regularly, at least once every year to confirm that all the safety functions are working properly. Warning! In case of breakdown or damage to the product, contact ABB. Do not try to repair the product yourself since it may accidentally cause permanent damage to the product, impairing the safety of the device which in turn could lead to serious injury to personnel.
  • Page 13: Troubleshooting

    Troubleshooting LED indications LED indication Probable cause Action Device interrupted Check status of the device. Bad connection to the Check cable to the light beam and device fasten carefully. +24 VDC connected to Check if there is +24 VDC on DYNlink signal input DYNlink signal input (pin-2).
  • Page 14: Dimensions

    Dimensions All dimensions are in mm. Tina 10A 11,2 13,4 Tina 10B 11,2 13,4 Tina 10C 11,2 13,4 2TLC010042M0201 Rev.C...
  • Page 15: Technical Data

    SE-721 61 Västerås Sweden Order code/Ordering data 2TLA020054R1210: Tina 10A v2 Adapter unit 2TLA020054R1310: Tina 10B v2 Adapter unit 2TLA020054R1610: Tina 10C v2 Adapter unit Power supply (Orion supply excluded) Required power supply type PELV/SELV, not intended to be connected to a DC distribution network.
  • Page 16 Housing material Connectors Tina 10A v2: M12 8-pole female, M12 5-pole male Tina 10B v2: M12 8-pole female, M12 5-pole female, M12 5-pole male Tina 10C v2: M12 8-pole female, M12 5-pole female, M12 5-pole male Tightening torque M12 connector: 0.6 Nm...
  • Page 17: Declaration Of Conformity

    Declaration of conformity EC Declaration of conformity 2TLC010042M0201 Rev.C...