Tina 2A/2B Adapter unit
Product Manual
2TLC172121M0201 Rev.E
ORIGINAL INSTRUCTIONS
new.abb.com/low-voltage/products/safety-products

Advertisement

Table of Contents
loading

Summary of Contents for ABB Tina 2A

  • Page 1 — SA F E T Y PR OD U CTS Tina 2A/2B Adapter unit Product Manual 2TLC172121M0201 Rev.E ORIGINAL INSTRUCTIONS new.abb.com/low-voltage/products/safety-products...
  • Page 2 Suitability for use ABB shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer’s application or use of the product. Third party certificates for the products are available at https://new.abb.com/low- voltage/products/safety-products.
  • Page 3: Table Of Contents

    Table of Contents 1 Introduction ..........................4 Purpose of document ........................ 4 Intended audience ........................4 Reading prerequisites ........................ 4 Special notes ..........................4 2 Safety ............................5 Safety precautions ........................5 3 Product description........................6 4 Installation........................... 7 Installation precautions ......................7 Testing safety functions ......................
  • Page 4: Introduction

    This document is intended for authorized personnel. Reading prerequisites It is assumed that the reader of this document has knowledge of the following: • Basic knowledge of ABB safety products • Knowledge of machine safety Special notes Pay attention to special notes in the document:...
  • Page 5: Safety

    Safety Safety precautions The safety precautions must be followed during installation, operation, maintenance and troubleshooting. It is the responsibility of the user to ensure the correct overall functionality. Warning! Carefully read through the entire product manual before using the device. Warning! The devices shall be installed by authorized personnel following applicable Safety regulations, standards and the Machinery directive.
  • Page 6: Product Description

    Product description Tina 2A and Tina 2B are used to adapt safety devices with zero-volt contacts to the DYNlink safety circuit monitored by a safety controller or a safety PLC. Examples of such safety devices are emergency stops and switches or light curtains and light beams with internal relay outputs.
  • Page 7: Installation

    Installation • The Tina unit shall be attached to the M20 entry (Tina 2A) before the safety cables are connected to the device. • See max. tightening torque in chapter “Technical data”. Installation precautions Warning! All safety functions shall be tested before starting up the system.
  • Page 8: Connections

    Connections Connection cables to DYNlink safety circuit 1 Brown +24 VDC 2 White DYNlink signal input 3 Blue 0 VDC 4 Black DYNlink signal output 5 Grey Information output Note! See connection cable cross section area and cable length in chapter 'Technical data/General'.
  • Page 9: Connection Examples

    Connection examples Caution! All cable colors according to ABB standard cables. 2TLC172121M0201 Rev.E...
  • Page 10: Functions

    Functions LED indications LED indication Description DYNlink state Green DYNlink input signal Green/red flashing DYNlink input open or 0 VDC Interrupted before this unit DYNlink input +24VDC Interrupted before this unit Information output signal attributes The information output of the unit is set either high or low according to the following table: DYNlink input signal status Information output DYNlink signal...
  • Page 11: Maintenance

    (EN 62061:2005+A1:2013+A2:2015, EN ISO 13849-1:2015). Warning! In case of breakdown or damage to the product, contact ABB. Do not try to repair the product yourself since it may accidentally cause permanent damage to the product, impairing the safety of the device which in turn could lead to serious injury to personnel.
  • Page 12: Troubleshooting

    Troubleshooting LED indications LED indication Probable cause Action +24 VDC connected to Check if there is +24 VDC on DYNlink signal input DYNlink signal input. If yes, check cable connections or the unit before. No LED light Loss of power supply Check +24 VDC/0 VDC power supply.
  • Page 13: Dimensions

    Dimensions All dimensions are in mm. Tina 2A Tina 2B 2TLC172121M0201 Rev.E...
  • Page 14: Technical Data

    Manufacturer Address ABB Electrification Sweden AB SE-721 61 Västerås Sweden Order code/Ordering data 2TLA020054R0100: Tina 2A Adapter unit 2TLA020054R1100: Tina 2B Adapter unit Power supply Required power supply type PELV/SELV, not intended to be connected to a DC distribution network.
  • Page 15 Conductor material: Tinned stranded copper Tightening torque 2-2.3 Nm (Tina 2A) Size (L x W x H) Tina 2A: 46 x 27 x 24 mm Tina 2B: 26 x 21 x 7 mm Weight Tina 2A: ~ 30 g Tina 2B: ~ 20 g...