Technical Data - ABB Tina 10B Product Manual

Adapter unit
Hide thumbs Also See for Tina 10B:
Table of Contents

Advertisement

10

Technical data

Further information about the product and accessories is found at:
new.abb.com/low-voltage/products/safety-products
Stated technical data apply when power supply voltage is +24 VDC and ambient temperature
is +25 °C, unless stated otherwise.
Manufacturer
Address
Order code/Ordering data
Power supply (Orion supply excluded)
Required power supply type
Operating voltage
Total current consumption
Note: Total current consumption is the supply current when there is no information
output current. Valid over the operating voltage and ambient temperature range.
DYNlink signal
DYNlink Input signal voltage
DYNlink Output signal voltage
Note: The purpose of stating the voltage in RMS is to facilitate the measurement of the
square-wave DYNlink signal with a multimeter.
Time delay between DYNlink
input and output signal (T
Information output
Output voltage high
Output current
OSSD inputs
Input current per channel
General
Protection class
Ambient temperature
Humidity range
2TLC010042M0201 Rev.C
ABB Electrification Sweden AB
SE-721 61 Västerås
Sweden
2TLA020054R1210: Tina 10A v2 Adapter unit
2TLA020054R1310: Tina 10B v2 Adapter unit
2TLA020054R1610: Tina 10C v2 Adapter unit
PELV/SELV, not intended to be connected to a DC
distribution network.
Note: A DC distribution network is defined in
IEC 61326-3-1:2017 as "Local DC electricity supply
network in the infrastructure of a certain site or
building intended for connection of any type of
equipment".
+24 VDC
Nominal: 25 mA
Maximum: 35 mA
Minimum: 8 V
Maximum: 15 V
Minimum: 8 V
Maximum: 15 V
Maximum: 120 µs
)
DELAY
Nominal: Operating voltage - 2 VDC
low
Maximum: 2 VDC
Maximum: 10 mA
Nominal: 10 mA
IP67
Operation: -10 to +55 °C
Storage: -10 to +55 °C
35 to 85 % (with no icing or condensation)
20 %
±
RMS
RMS
RMS