How to Program

4.2.16 DR-## Data Readouts

Par. No. #
Parameter description
DR-0#
DR-00
Control Word
DR-01
Reference [Unit]
DR-02
Reference %
DR-03
Status Word
DR-05
Main Actual Value [%]
DR-09
Custom Readout
DR-1#
DR-10
Power [kW]
DR-11
Power [hp]
DR-12
Motor Voltage
DR-13
Frequency
DR-14
Motor Current
DR-15
Frequency [%]
DR-16
Torque [Nm]
DR-17
Speed [RPM]
DR-18
Motor Thermal
DR-19
KTY sensor temperature
DR-2#
DR-20
Motor Angle
DR-21
Torque [%] High Res.
DR-22
Torque [%]
DR-25
Torque [Nm] High
DR-3#
DR-30
DC Link Voltage
DR-32
Brake Energy /s
DR-33
Brake Energy /2 min
DR-34
Heatsink Temp.
DR-35
Drive Thermal
DR-36
Drive Nominal Current
DR-37
Drive Max. Current
DR-38
Logic Controller State
DR-39
Control Card Temp.
DR-4#
DR-40
Trending Buffer Full
DR-49
Current Fault Source
DR-5#
DR-50
External Reference
DR-51
Pulse Reference
DR-52
Feedback [Unit]
DR-53
Digi Pot Reference
DR-6#
DR-60
Digital Input
DR-61
Terminal 53 Switch Setting
DR-62
Analog Input 53
DR-63
Terminal 54 Switch Setting
AF-650 GP High Power Operating Instructions
Default value
4-set-up
0 N/A
All set-ups
0.000 ReferenceFeed-
backUnit
All set-ups
0.0 %
All set-ups
0 N/A
All set-ups
0.00 %
All set-ups
0.00 CustomRea-
doutUnit
All set-ups
0.00 kW
All set-ups
0.00 hp
All set-ups
0.0 V
All set-ups
0.0 Hz
All set-ups
0.00 A
All set-ups
0.00 %
All set-ups
0.0 Nm
All set-ups
0 RPM
All set-ups
0 %
All set-ups
0 °C
All set-ups
0 N/A
All set-ups
0.0 %
All set-ups
0 %
All set-ups
0.0 Nm
All set-ups
0 V
All set-ups
0.000 kW
All set-ups
0.000 kW
All set-ups
0 °C
All set-ups
0 %
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
0 N/A
All set-ups
0 °C
All set-ups
[0] No
All set-ups
0 N/A
All set-ups
0.0 N/A
All set-ups
0.0 N/A
All set-ups
0.000 ReferenceFeed-
backUnit
All set-ups
0.00 N/A
All set-ups
0 N/A
All set-ups
[0] Current
All set-ups
0.000 N/A
All set-ups
[0] Current
All set-ups
Change
Conver-
during
sion index
operation
FALSE
0
FALSE
-3
FALSE
-1
FALSE
0
FALSE
-2
FALSE
-2
FALSE
1
FALSE
-2
FALSE
-1
FALSE
-1
FALSE
-2
FALSE
-2
FALSE
-1
FALSE
67
FALSE
0
FALSE
100
TRUE
0
FALSE
-1
FALSE
0
FALSE
-1
FALSE
0
FALSE
0
FALSE
0
FALSE
100
FALSE
0
FALSE
-2
FALSE
-2
FALSE
0
FALSE
100
TRUE
-
TRUE
0
FALSE
-1
FALSE
-1
FALSE
-3
FALSE
-2
FALSE
0
FALSE
-
FALSE
-3
FALSE
-
Type
V2
Int32
4
4
Int16
V2
N2
Int32
Int32
Int32
Uint16
Uint16
Int32
N2
Int16
Int32
Uint8
Int16
Uint16
Int16
Int16
Int32
Uint16
Uint32
Uint32
Uint8
Uint8
Uint32
Uint32
Uint8
Uint8
Uint8
Uint8
Int16
Int16
Int32
Int16
Uint16
Uint8
Int32
Uint8
75