2
Technology > Image Formation System > Servicing > When Replacing Parts
■
When Replacing Parts
When replacing the Periodically Replaced Parts and Consumable Parts, be sure to clear the
Parts Counter (COPIER > COUNTER > PRDC-1/DRBL-1)
●
Primary Charging Wire
<Procedure of parts replacement>
see "Replacing the Primary Charging Wire," on p. 4-103.
<Procedure of adjustment>
1) Clear the parts counter. (COPIER>COUNTER>PRDC-1>PRM-WIRE)
2) Clean the Charging Wire. (COPIER>FUNCTION>CLEANING>WIRE-CLN)
3) Init of Primary Charging Wire current VL(COPIER>ADJUST>HV-PRI>PRI-GRID)
4) Execute the potential control (COPIER>FUNCTION>DPC>DPC). Turn OFF and then ON
the main power. (The potential control is executed at startup.)
5) Execute the potential control. (COPIER>FUNCTION>DPC>DPC)
6) Turn OFF and then ON the main power switch.
●
Primary Charging Assembly
<Procedure of parts replacement>
see "Removing the Primary Charging Assembly," on p. 4-96.
<Procedure of adjustment>
1) Output a halftone image using the service mode.
•
TEST > PG > TYPE : 5
2) Execute the following procedure according to the density difference on the front and rear
sides of the test print image.
•
When the front side test print image is dark, execute step 3.
•
When the rear side test print image is dark, execute step 4.
•
When there is no uneven density, execute step 5 and the following.
When the front side test print image is dark
MEMO:
•
When the front side test print image is dark [1], execute step 3 until the density
becomes even. When the density becomes even, execute step 5 and the following.
•
When the adjustment screw is turned clockwise, the Charging Wire goes down and
up (gap between grid and Charging Wire becomes narrow and wide). As a result, the
density of output image becomes light.
2
Technology > Image Formation System > Servicing > When Replacing Parts
Note:
Be sure to adjust the dark side (density of the test print image) to be the light side.
2-89