Siemens RUGGEDCOM RSG920P Installation Manual

Hide thumbs Also See for RUGGEDCOM RSG920P:

Advertisement

RUGGEDCOM RSG920P
Installation Guide
07/2018
RC1172-EN-05
Preface
Introduction
Installing the Device
Device Management
Communication Ports
Technical Specifications
Certification
1
2
3
4
5
6

Advertisement

Table of Contents
loading

Summary of Contents for Siemens RUGGEDCOM RSG920P

  • Page 1 Preface Introduction Installing the Device RUGGEDCOM RSG920P Device Management Communication Ports Technical Specifications Installation Guide Certification 07/2018 RC1172-EN-05...
  • Page 2: Security Information

    Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 3 RUGGEDCOM RSG920P Installation Guide Contacting Siemens Address Telephone E-mail Siemens Canada Ltd Toll-free: 1 888 264 0006 ruggedcom.info.i-ia@siemens.com Industry Sector Tel: +1 905 856 5288 300 Applewood Crescent Fax: +1 905 856 1995 Concord, Ontario https://www.siemens.com/ruggedcom Canada, L4K 5C7...
  • Page 4 RUGGEDCOM RSG920P Installation Guide...
  • Page 5: Table Of Contents

    RUGGEDCOM RSG920P   Installation Guide Table of Contents Table of Contents Preface ......................Alerts ..............................vii Related Documents ..........................viii Accessing Documentation ........................viii Training ............................viii Customer Support ..........................viii Chapter 1 Introduction ..................... 1.1  Feature Highlights ........................1 1.2    Description ........................... 2 1.3  Required Tools and Materials ......................
  • Page 6   RUGGEDCOM RSG920P Table of Contents Installation Guide 3.3  Inserting/Removing the MicroSD Card ................... 21 Chapter 4 Communication Ports ..................4.1  Copper Ethernet Ports ......................... 23 4.2  SFP Transceivers ......................... 25 4.3    PoE Ports ............................ 26 Chapter 5 Technical Specifications .................. 5.1  Power Supply Specifications ......................29 5.2  PoE Power Supply Specifications ....................
  • Page 7: Preface

    Installation Guide Preface Preface This guide describes the RUGGEDCOM RSG920P. It describes the major features of the device, installation, commissioning and important technical specifications. It is intended for use by network technical support personnel who are responsible for the installation, commissioning and maintenance of the device.
  • Page 8: Related Documents

    Siemens Sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request...
  • Page 9 Installation Guide Preface Mobile App Install the Industry Online Support app by Siemens AG on any Android, Apple iOS or Windows mobile device and be able to: • Access Siemens' extensive library of support documentation, including FAQs and manuals • Submit SRs or check on the status of an existing SR •...
  • Page 10: Customer Support

      RUGGEDCOM RSG920P Preface Installation Guide Customer Support...
  • Page 11: Introduction

    • The four SFP slots provide ultimate flexibility in up-link distances and bandwidth, with support for Gigabit and Fast Ethernet. • The four PoE ports supply up to 120 W (30 W per port) of power, allowing the RUGGEDCOM RSG920P to accommodate various PoE devices, such as cameras, intercom devices, Wireless LAN Access points and Bluetooth sensors.
  • Page 12: Description

    • CSA/UL 60950-1 safety approved to 85 °C (185 °F) Section 1.2 Description The RUGGEDCOM RSG920P features various ports, controls and indicator LEDs on the front panel for connecting, configuring and troubleshooting the device. Figure 1: RUGGEDCOM RSG920P 1. RS-232 Console Port (RJ45)    2. POWER LED    3. ALARM LED    4. SFP Ethernet Ports    5. Access Plate    6. 10/100/1000 Mbps Copper Ethernet Ports   ...
  • Page 13: Required Tools And Materials

    • Section 5.1, “Power Supply Specifications” Section 1.3 Required Tools and Materials The following tools and materials are required to install the RUGGEDCOM RSG920P: Tools/Materials Purpose RUGGEDCOM RPS1300 or equivalent 54 VDC output power supply For supplying PoE power to the device.
  • Page 14: Decommissioning And Disposal

    Chapter 1 RUGGEDCOM RSG920P Introduction Installation Guide Section 1.4 Decommissioning and Disposal Proper decomissioning and disposal of this device is important to prevent malicious users from obtaining proprietary information and to protect the environment. Decommissioning This device may include sensitive, proprietary data. Before taking the device out of service, either permanently or for maintenance by a third-party, make sure it has been fully decommissioned.
  • Page 15: Installing The Device

    IMPORTANT! The RUGGEDCOM RSG920P may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended/approved by Siemens. Proper transport, storage, installation,...
  • Page 16: General Procedure

    Do not install the RUGGEDCOM RSG920P in a nuclear power plant or other nuclear-related facilities. IMPORTANT! The RUGGEDCOM RSG920P must be located in an area accessible only by qualified service personnel or other authorized users. Operation of the device is permitted only when this requirement is met.
  • Page 17: Installing The Device In Hazardous Locations

    Installing the Device in Hazardous Locations The RUGGEDCOM RSG920P is designed to comply with the safety standards for Class I, Division 2, Zone 2 hazardous locations where concentrations of flammable gases, vapors or liquids may be present, as opposed to normal operating environments.
  • Page 18: Mounting The Device

    Section 2.4.1 Mounting the Device on a DIN Rail For DIN rail installations, the RUGGEDCOM RSG920P can be equipped with a DIN rail bracket that allows the device to be slid onto a standard 35 mm (1.4 in) DIN rail. To mount the device to a DIN rail, do the following: Secure the DIN rail bracket to back of the device chassis.
  • Page 19: Mounting The Device To A Panel

    Section 2.4.2 Mounting the Device to a Panel For panel installations, the RUGGEDCOM RSG920P can be equipped with panel adapters that allow the device to be attached to a panel in multiple orientations. NOTE A side mount orientation requires additional adapters.
  • Page 20 Chapter 2 RUGGEDCOM RSG920P Installing the Device Installation Guide Figure 5: Panel Mount Options 1. Rear Mount Orientation    2. Front Mount Orientation    3. Side Mount Orientation To mount the device to a panel, do the following: Secure the adapters to the device in the desired orientation.
  • Page 21: Grounding The Device

    Section 2.5 Grounding the Device The RUGGEDCOM RSG920P chassis features a threaded hole for connecting the device to ground (Protective Earth). It is recommended to terminate the ground connection with an M3 ring or spade lug, and then torque to 1.7 N·m (15 lbf-in).
  • Page 22: Connecting The Digital Inputs

    Section 2.7 Connecting the Digital Inputs The RUGGEDCOM RSG920P offers two independent digital inputs for monitoring external equipment. Each digital input is associated with an alarm that is configured in RUGGEDCOM ROS. Depending on the configuration, the associated alarm may be triggered if the digital input is in either the HIGH or LOW state.
  • Page 23: Connecting Power

    Connect the negative cable to the DI1/2- terminal. Section 2.8 Connecting Power The RUGGEDCOM RSG920P supports a single integrated high AC/DC or low DC power supply, as well as an external power supply for the Power-over-Ethernet (PoE) ports. IMPORTANT! • For 110/230 VAC rated equipment, an appropriately rated AC circuit breaker must be installed •...
  • Page 24: Connecting Low Dc Power

    Chapter 2 RUGGEDCOM RSG920P Installing the Device Installation Guide CAUTION! Electrical hazard – risk of damage to equipment. Do not connect AC power cables to terminals for DC power. Damage to the power supply may occur. Secure a European-style terminal block (or Euroblock) to the terminal.
  • Page 25: Connecting External Poe Power

    Connect the negative wire from the power source to the negative terminal on the terminal block. Connect the ground wire to the chassis ground terminal on the device. Section 2.8.3 Connecting External PoE Power The RUGGEDCOM RSG920P supports four 10/100/1000 Mbps Power-over-Ethernet (POE) Ports that require external power. Connecting External PoE Power...
  • Page 26 For IEC 61850 compliance, use an IEC 61850 compliant PoE power supply with power cabling no longer than 3 m (118 in). Otherwise, Siemens recommends using the RUGGEDCOM RPS1300 switch-mode AC power supply. For more information about this power supply, refer to https://support.industry.siemens.com/cs/ww/en/...
  • Page 27 RUGGEDCOM RSG920P Chapter 2 Installation Guide Installing the Device If using an external power supply other than the RUGGEDCOM RPS1300 that has a chassis ground connection, connect the ground terminal on the power supply to the chassis ground terminal on the device.
  • Page 28 Chapter 2 RUGGEDCOM RSG920P Installing the Device Installation Guide Connecting External PoE Power...
  • Page 29: Device Management

    For Microsoft Windows users, the RUGGEDCOM USB Serial Console driver must be installed on the users workstation before connecting via the USB Type-B console port. For more information, refer to the RUGGEDCOM ROS User Guide for the RUGGEDCOM RSG920P. Connecting to the Device...
  • Page 30: Communication Ports

    Chapter 3 RUGGEDCOM RSG920P Device Management Installation Guide Figure 14: Console Ports 1. RJ45 Console Port    2. USB Type-B Console Port    3. Access Plate Connection to the RJ45 console port is made using an RJ45-to-DB9 console cable. The following is the pin-out for the RJ45 console port:...
  • Page 31: Configuring The Device

    RUGGEDCOM ROS User Guide associated with the installed software release. Section 3.3 Inserting/Removing the MicroSD Card The RUGGEDCOM RSG920P accepts a microSD card for storing configuration files and/or software updates. CAUTION! Configuration hazard – risk of data loss. The microSD card must not be removed or replaced while the device is booting up or when configuration changes are being made.
  • Page 32 Chapter 3 RUGGEDCOM RSG920P Device Management Installation Guide Figure 16: Inserting/Removing a MicroSD Card 1. MicroSD Card    2. Access Plate When removing the card, first press the card in until it springs back. Without touching the contacts on the card, insert or remove the microSD card.
  • Page 33: Communication Ports

    RUGGEDCOM RSG920P Chapter 4 Installation Guide Communication Ports Communication Ports The RUGGEDCOM RSG920P can be equipped with various types of communication ports to enhance its abilities and performance. Figure 17: Port Assignment 1. SFP Transceiver Sockets    2. Copper Ethernet Ports    3. PoE+ Ports Port Type...
  • Page 34 Chapter 4 RUGGEDCOM RSG920P Communication Ports Installation Guide are directly connected to the chassis ground on the device and can accept CAT-5 shielded twisted-pair (STP) cables. WARNING! Electric shock hazard – risk of serious personal injury and/or equipment interference. If shielded cables are used, make sure the shielded cables do not form a ground loop via the shield wire and the RJ45 receptacles at either end.
  • Page 35: Sfp Transceivers

    Link established Green (Blinking) Activity No link detected Compatible SFP Transceivers The following SFP transceivers are compatible with the RUGGEDCOM RSG920P. For more information, including installation/removal instructions and ordering information, refer to the RUGGEDCOM SFP Transceiver Catalog [https://support.industry.siemens.com/cs/ca/en/view/109482309]. IMPORTANT! Only use SFP transceivers approved by Siemens for RUGGEDCOM products. Siemens accepts no liability as a result of performance issues related in whole or in part to third-party components.
  • Page 36: Poe Ports

    Section 4.3 PoE Ports The RUGGEDCOM RSG920P supports four Power over Ethernet (POE) ports (ports 13 to 16) powered by an external power supply. Each port complies with the IEEE 802.3at standard. The total allowable power budget for all ports is 120 W. If the external power supply is less than 120 W, to prevent exceeding the power budget, port priorities can be set via the RUGGEDCOM ROS operating system to disable low priority ports when demand is too high.
  • Page 37: Specifications

    RUGGEDCOM RSG920P Chapter 4 Installation Guide Communication Ports Name PoE Voltage 54 V Nominal Description 10/100Base- Ports 13 Ports 14 1000Base-TX and 15 and 16 BI_DB+ Receive Data + or Bi- Directional Figure 21: PoE Port Pin Configuration BI_DB- Receive Data- or Bi-...
  • Page 38 Chapter 4 RUGGEDCOM RSG920P Communication Ports Installation Guide PoE Ports...
  • Page 39: Technical Specifications

    (T) denotes time-delay fuse. Power consumption varies based on configuration. Section 5.2 PoE Power Supply Specifications The RUGGEDCOM RSG920P adheres to the following power output and IEEE specifications depending on the input voltage supplied to the device. Power In Power Out...
  • Page 40: Failsafe Alarm Relay Specifications

    Chapter 5 RUGGEDCOM RSG920P Technical Specifications Installation Guide Power In Power Out Voltage Range Internal Fuse Rating 45-57 VDC 44-57 VDC, 15 W per Port Maximum (IEEE 302.af) Section 5.3 Failsafe Alarm Relay Specifications Maximum Switching Voltage Rated Switching Current Isolation 30 VDC 2.0 A...
  • Page 41: Operating Environment

    RUGGEDCOM RSG920P Chapter 5 Installation Guide Technical Specifications Section 5.6 Operating Environment Parameter Range Comments Ambient Operating Temperature -40 to 85 °C Measured from a 30 cm (12 in) radius surrounding the center of the (-40 to 185 °F) enclosure. Ambient Relative Humidity...
  • Page 42 Chapter 5 RUGGEDCOM RSG920P Technical Specifications Installation Guide 165.6 152.0 154.0 Figure 22: Overall Dimensions Figure 23: Panel Mount Dimensions (Rear Mount Shown) Dimension Drawings...
  • Page 43 RUGGEDCOM RSG920P Chapter 5 Installation Guide Technical Specifications 130.3 117.6 79.5 Figure 24: Panel Mount Dimensions (Side Mount Shown) Figure 25: DIN Rail Mount Dimensions Dimension Drawings...
  • Page 44 Chapter 5 RUGGEDCOM RSG920P Technical Specifications Installation Guide Dimension Drawings...
  • Page 45: Certification

    RUGGEDCOM RSG920P Chapter 6 Installation Guide Certification Certification The RUGGEDCOM RSG920P device has been thoroughly tested to guarantee its conformance with recognized standards and has received approval from recognized regulatory agencies. CONTENTS • Section 6.1, “Approvals” • Section 6.2, “EMC and Environmental Type Tests”...
  • Page 46: Csa/Sira

    Chapter 6 RUGGEDCOM RSG920P Certification Installation Guide • CAN/CSA-C22.2 No. 213-M1987 Non-Incendive Electrical Equipment for Use in Class I, Division 2 Hazardous Locations • CAN/CSA-C22.2 No. 60079-0:11 Explosive Atmospheres – Part 0: Equipment – General Requirements • CAN/CSA-C22.2 No. 60079-15:12 Electrical Apparatus for Explosive Gas Atmospheres –...
  • Page 47: Tüv Süd

    Information Technology Equipment – Safety – Part 1: General Requirements) Section 6.1.4 European Union (EU) This device is declared by Siemens Canada Ltd to comply with essential requirements and other relevant provisions of the following EU directives: • 94/9/EC (ATEX) ATEX – Directive of the European Parliament and the Council of 23 March 1994 on the Approximation of the...
  • Page 48: Fcc

    Chapter 6 RUGGEDCOM RSG920P Certification Installation Guide A copy of the CE Declaration of Conformity is available from Siemens Canada Ltd. For contact information, refer to “Contacting Siemens”. Notices specific to the European Union: WARNING! Communication hazard – risk of radio interference. This is a Class A product. In a domestic environment this product may cause radio interference, in which case the user may be required to take adequate measures.
  • Page 49: Rra

    Radio Waves Act. As such, the device is marked with a KC symbol and can be used in the Republic of Korea (South Korea) as a Class A product in a commercial, industrial or business environment. MSIP-REM-S14-RSG920P A copy of the KC Declaration of Conformity is available from Siemens Canada Ltd. For contact information, refer to “Contacting Siemens”.
  • Page 50: Rohs

    Installation Guide Section 6.1.10 RoHS This device is declared by Siemens Canada Ltd to meet the requirements of the following RoHS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: • China RoHS 2...
  • Page 51 RUGGEDCOM RSG920P Chapter 6 Installation Guide Certification Test Description Test Levels Severity Levels Enclosure Air ±15 kV IEC 61000-4-3 Radiated Radio Frequency Enclosure Ports 20 V/m Immunity (RFI) IEC 61000-4-4 Burst (Electrical Fast Transient) Signal Ports ±4 kV at 2.5 kHz...
  • Page 52 EMC Immunity Type Tests per IEEE 1613 NOTE The RUGGEDCOM RSG920P meets Class 2 requirements for an all-fiber configuration and Class 1 requirements for copper ports. Class 1 allows for temporary communication loss, while Class 2 requires error-free and interrupted communications.
  • Page 53: Environmental Type Tests

    RUGGEDCOM RSG920P Chapter 6 Installation Guide Certification Environmental Type Tests Test Description Test Levels Severity Levels IEC 60068-2-1 Cold Temperature Test Ad -40 °C (-40 °F), 16 Hours IEC 60068-2-2 Dry Heat Test Bd 85 °C (185 °F), 16 Hours...
  • Page 54 Chapter 6 RUGGEDCOM RSG920P Certification Installation Guide EMC and Environmental Type Tests...

Table of Contents