Siemens SIMATIC NET RUGGEDCOM RSG909R Installation Manual
Siemens SIMATIC NET RUGGEDCOM RSG909R Installation Manual

Siemens SIMATIC NET RUGGEDCOM RSG909R Installation Manual

Rugged ethernet switches
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RSG909R:

Advertisement

Quick Links

Edition
04/2023
Installation Manual
SIMATIC NET
Rugged Ethernet Switches
RUGGEDCOM RSG909R
https://www.siemens.com/ruggedcom

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC NET RUGGEDCOM RSG909R

  • Page 1 Edition 04/2023 Installation Manual SIMATIC NET Rugged Ethernet Switches RUGGEDCOM RSG909R https://www.siemens.com/ruggedcom...
  • Page 2 Preface Introduction Installing the Device SIMATIC NET Device Management Rugged Ethernet Switches RUGGEDCOM RSG909R Communication Ports Technical Specifications Installation Manual Certification 04/2023 C79000-G8976-1388-17...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Table Of Contents

    Accessing documentation ......................v Registered trademarks ......................vi Warranty ..........................vi Training ..........................vi Customer support ........................vii Contacting Siemens ....................... vii Introduction ........................... 1 Feature Highlights ....................2 Description ......................2 Required Tools and Materials ................. 4 Decommissioning and disposal ................4 Cabling Recommendations ..................
  • Page 5 Table of contents Supported Networking Standards ................ 31 Copper Ethernet Port Specifications ..............32 Operating Environment ..................33 Mechanical Specifications ..................33 Dimension Drawings ................... 33 Certification ......................... 35 Approvals ......................35 6.1.1 UKCA ........................35 6.1.2 European Union (EU) ..................35 6.1.3 FCC ........................
  • Page 6: Preface

    SIMATIC NET Glossary The SIMATIC NET Glossary describes special terms that may be used in this document. The glossary is available online via Siemens Industry Online Support (SIOS) at: https://support.industry.siemens.com/cs/ww/en/view/50305045 Accessing documentation The latest user documentation for RUGGEDCOM RSG909R is available online at https://support.industry.siemens.com.
  • Page 7: Registered Trademarks

    Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 8: Customer Support

    Call a local hotline center to submit a Support Request (SR). To locate a local hotline center, visit https://w3.siemens.com/aspa_app/?lang=en. Mobile app Install the Industry Online Support app by Siemens AG on any Android, Apple iOS or Windows mobile device and be able to: •...
  • Page 9 Preface Contacting Siemens viii RUGGEDCOM RSG909R Installation Manual, 04/2023, C79000-G8976-1388-17...
  • Page 10: Introduction

    Ports designated for Redundant Network Access (RNA) – ports A/B and 7 – can be customized with a wide array of Small Form-factor Portable (SFP) transceivers offered by Siemens, making the device flexible to the needs of the redundant network application.
  • Page 11: Feature Highlights

    Introduction 1.1 Feature Highlights Feature Highlights Ethernet Ports • 6 x 10/100/1000Base-TX copper Ethernet ports • 3 x 1000Base-SX/LX SFP transceivers Rated for Reliability in Harsh Environments • Immunity to EMI and heavy electrical surges • -40 to 85 °C (-40 to 185 °F) ambient operating temperature (no fans) •...
  • Page 12 Introduction 1.2 Description POWER LED ALARM LED USB Console Port RNA Port (Port A/B) Port 7 Copper Ethernet Ports (Ports 1 to 6) Failsafe Alarm Relay Power Supply Terminal Blocks Chassis Ground Screw Figure 1.1 RUGGEDCOM RSG909R POWER LED Illuminates green during boot up and when power is supplied to the device.
  • Page 13: Required Tools And Materials

    WEEE directive 2012/19/EU for the disposal of electrical and electronic equipment. Do not dispose of devices at public disposal sites. For environmentally friendly recycling and the disposal of devices, contact a certified disposal company for electronic scrap or your Siemens contact. For more information, refer to https://support.industry.siemens.com/cs/ww/en/ view/109479891.
  • Page 14: Cabling Recommendations

    Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground fault conditions.
  • Page 15 Introduction 1.5 Cabling Recommendations RUGGEDCOM RSG909R Installation Manual, 04/2023, C79000-G8976-1388-17...
  • Page 16: Installing The Device

    Installing the Device This chapter describes how to install the device, including mounting the device, connecting power, and connecting the device to the network. DANGER Electrocution hazard – risk of serious personal injury and/or damage to equipment Before performing any maintenance tasks, make sure all power to the device has been disconnected and wait approximately two minutes for any remaining energy to dissipate.
  • Page 17: General Procedure

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens Canada Ltd. could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 18: Unpacking The Device

    Visually inspect each item in the package for any physical damage. Verify all items are included. Note If any item is missing or damaged, contact Siemens for assistance. Mounting the Device The RUGGEDCOM RSG909R is designed for maximum mounting and display flexibility.
  • Page 19 Installing the Device 2.3.1 Mounting the Device on a DIN Rail Mounting the Device To mount the device to a DIN rail, do the following: Hook the top teeth of the adapter onto the DIN rail. Note The adapter features a sliding release with a slot at the bottom for a flathead screwdriver.
  • Page 20: 2.3.2 Mounting The Device To A Panel

    Installing the Device 2.3.2 Mounting the Device to a Panel DIN Rail DIN Rail Adapter Figure 2.2 Removing the Device from a DIN Rail Swing the bottom of the device away from the DIN rail. Lift the device off the DIN rail. 2.3.2 Mounting the Device to a Panel For panel installations, the RUGGEDCOM RSG909R can be equipped with panel...
  • Page 21 Installing the Device 2.3.2 Mounting the Device to a Panel Screw (M4) Panel Mount Adapter Figure 2.3 Panel Mount Adapter Assembly Prepare mounting holes in the panel where the device is to be installed. Place the device against the panel and align the adapters with the mounting holes.
  • Page 22: Connecting The Failsafe Alarm Relay

    Installing the Device 2.4 Connecting the Failsafe Alarm Relay Secure the adapters to the panel with M5 or #10-24 screws. Connecting the Failsafe Alarm Relay The failsafe relay can be configured to latch based on alarm conditions. The NO (Normally Open) contact is closed when the unit is powered and there are no active alarms.
  • Page 23: Connecting Power

    Installing the Device 2.5 Connecting Power Failsafe Alarm Relay Terminal Block Normally Open Common Normally Closed Figure 2.6 Failsafe Alarm Relay Wiring Connecting Power The RUGGEDCOM RSG909R features two input terminals that allow the device to be powered by: • Up to one independent AC and one independent DC power source •...
  • Page 24: Connecting Ac Or Dc Power

    Installing the Device 2.5.1 Connecting AC or DC Power the maximum amount of current transfer is below the safety threshold, it may be enough to trip some external Ground Fault Circuit Interrupter (GFCI) breakers. Before connecting power, review the installation and make sure this condition can be supported.
  • Page 25 Installing the Device 2.5.1 Connecting AC or DC Power Power Source Terminal Block Type 3 POS 5 POS Figure 2.7 Assembling the Power Terminal Blocks Note Torque all terminal connections to 0.6 N·m (5 lbf-in). Connect the power cable to the device as follows: HI AC/DC Power Supply  ...
  • Page 26: 2.5.2 Wiring Examples

    Installing the Device 2.5.2 Wiring Examples Connect the ground wire to the chassis/ground terminal on the terminal block. Connect the chassis ground screw to ground (Potential Earth). It is recommended to terminate the ground connection with an M4 ring or spade lug, and then torque to 1.7 N·m (15 lbf-in).
  • Page 27 Installing the Device 2.5.2 Wiring Examples HI Power Supply Configurations   Figure 2.10 Single HI AC Power Input Figure 2.11 Single HI DC Power Input Configuration Configuration RUGGEDCOM RSG909R Installation Manual, 04/2023, C79000-G8976-1388-17...
  • Page 28 Installing the Device 2.5.2 Wiring Examples   Figure 2.12 Dual HI AC and DC Power Figure 2.13 Dual HI DC Power Supplies Supplies RUGGEDCOM RSG909R Installation Manual, 04/2023, C79000-G8976-1388-17...
  • Page 29: Connecting The Device To The Network

    Installing the Device 2.6 Connecting the Device to the Network LO Power Supply Configurations   Figure 2.14 Single LO DC Power Input Figure 2.15 Dual LO DC Power Input Configuration Configuration Connecting the Device to the Network Steps to connect the device to the network are application-specific. RUGGEDCOM RSG909R Installation Manual, 04/2023, C79000-G8976-1388-17...
  • Page 30 Installing the Device 2.6 Connecting the Device to the Network Connecting to a Local Area Network In this application, the device operates as a switch on a Local Area Network (LAN). Connect the device as follows:   Port Connect To... Not used Not used 7 (Coupler) Connect to an Ethernet-...
  • Page 31 Installing the Device 2.6 Connecting the Device to the Network DAN (RUGGEDCOM RSG909R RSG907R) Figure 2.17 A PRP Network Connecting to an HSR Ring In this application, the device operates as an HSR RedBox in an HSR ring. Connect the device as follows:  ...
  • Page 32 Installing the Device 2.6 Connecting the Device to the Network Connecting an HSR Ring and PRP Network In this application, the device operates as one of two HSR/PRP RedBoxes in an HSR ring that is connected to either LAN A or LAN B in the PRP network. Connect the device as follows:  ...
  • Page 33 Installing the Device 2.6 Connecting the Device to the Network   Port Connect To... Connect to port B of the neighboring HSR/HSR RedBox or to the HSR ring Connect to port A of the neighboring HSR/HSR RedBox or to the HSR ring 7 (Coupler) Connect to the coupling...
  • Page 34: Device Management

    Device Management This section describes how to connect to and manage the device. Connecting to the Device The following describes the various methods for accessing the RUGGEDCOM RSG909R console and Web interfaces on the device. For more detailed instructions, refer to the "RUGGEDCOM ROS Configuration Manual" for the RUGGEDCOM RSG909R.
  • Page 35: Configuring The Device

    Device Management 3.2 Configuring the Device device's IP address. The factory default IP address for the RUGGEDCOM RSG909R is https://192.168.0.1. For more information about available ports, refer to "Communication Ports" (Page 27). Configuring the Device Once the device is installed and connected to the network, it must be configured. All configuration management is done via the RUGGEDCOM RSG909R interface.
  • Page 36: Communication Ports

    Communication Ports The RUGGEDCOM RSG909R can be equipped with various types of communication ports to enhance its abilities and performance. Ports A and B Port 7 Ports 1 to 6 Figure 4.1 Port Assignment Port Type SFP Transceiver (1000Base-SX/LX) SFP Transceivers (1000Base-SX/LX) 1 to 6 Copper (10/100/1000Base-TX) Ethernet Ports Redundant Network Access (RNA) Ports...
  • Page 37 "RUGGEDCOM SFP Transceiver Catalog [https:// support.industry.siemens.com/cs/ca/en/view/109482309]". NOTICE Only use SFP transceivers approved by Siemens for RUGGEDCOM products. Siemens accepts no liability as a result of performance issues related in whole or in part to third-party components. NOTICE RNA ports A and B must operate at the same speed.
  • Page 38: Copper Ethernet Ports

    Communication Ports 4.2 Copper Ethernet Ports Copper Ethernet Ports The RUGGEDCOM RSG909R supports multiple 10/100/1000Base-TX Ethernet ports that allow connection to standard Category 5 (CAT-5) shielded twisted-pair cables with RJ45 male connectors. WARNING Electric shock hazard – risk of serious personal injury and/or equipment interference When shielded cables are used, make sure the shielded cables do not form a ground loop via the shield wire and the RJ45 receptacles at either end.
  • Page 39 Communication Ports 4.2 Copper Ethernet Ports Name Description 10/100Base-TX 1000Base-TX Reserved (Do Not Connect) BI_DC- Bi-Directional Specifications For specifications on the available copper Ethernet ports, refer to "Copper Ethernet Port Specifications" (Page 32). RUGGEDCOM RSG909R Installation Manual, 04/2023, C79000-G8976-1388-17...
  • Page 40: Technical Specifications

    Technical Specifications This section provides important technical specifications related to the device. Power Supply Specifications Note When determining cable lengths, make sure the nominal input voltage for the power supply is provided at the power source. Power Input Voltage Internal Isolation Maximum Supply Type...
  • Page 41: Copper Ethernet Port Specifications

    Technical Specifications 5.4 Copper Ethernet Port Specifications Standard 10 Mbps 100 Mbps 1000 Mbps Ports Notes Ports Ports IEEE 802.3z     1000Base-LX Ÿ IEEE 802.3ab     1000Base-Tx Ÿ IEEE 802.1D MAC Bridges Ÿ Ÿ Ÿ IEEE 802.1Q VLAN (Virtual LAN) Ÿ...
  • Page 42: Operating Environment

    Technical Specifications 5.5 Operating Environment Operating Environment The RUGGEDCOM RSG909R is rated to operate under the following environmental conditions. Ambient Operating -40 to 85 °C (-40 to 185 °F) Temperature Ambient Storage Temperature -40 to 85 °C (-40 to 185 °F) Ambient Relative Humidity 5% to 95% Maximum Altitude...
  • Page 43 Technical Specifications 5.7 Dimension Drawings 38.1 163.12 Figure 5.2 Panel Mount Dimensions 162.72 Figure 5.3 DIN Rail Mount Dimensions RUGGEDCOM RSG909R Installation Manual, 04/2023, C79000-G8976-1388-17...
  • Page 44: Certification

    Assessed (UKCA) marking. The marking is printed on the body of the device. 6.1.2 European Union (EU) This device is declared by Siemens Canada Ltd. to comply with essential requirements and other relevant provisions of the following EU directives: •...
  • Page 45: 6.1.3 Fcc

    Title 21 Code of Federal Regulations (CFR) – Chapter I – Sub-chapter J – Radiological Health 6.1.5 ISED This device is declared by Siemens Canada Ltd. to meet the requirements of the following ISED (Innovation Science and Economic Development Canada) standard: • CAN ICES-3 (A)/NMB-3 (A)
  • Page 46: Tüv Süd

    Republic of Korea (South Korea) as a Class A product in a commercial, industrial or business environment. R-REM-S14-RSG909R A copy of the KC Declaration of Conformity is available from Siemens Canada Ltd.. For contact information, refer to "Contacting Siemens" (Page vii). Notices specific to the RRA:...
  • Page 47: 6.1.9 Anatel

    6.1.10 RoHS This device is declared by Siemens Canada Ltd. to meet the requirements of the following RoHS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: •...
  • Page 48: Emc And Environmental Type Tests

    Certification 6.2 EMC and Environmental Type Tests • IEC 61000-6-2 Electromagnetic Compatibility (EMC) – Part 6-2: Generic Standards – Immunity for Industrial Environments EN 50121-4 • Railway applications – Electromagnetic Compatibility – Emission and Immunity of the Signaling and Telecommunications Apparatus EN 50121-3-2 •...
  • Page 49 Certification 6.2 EMC and Environmental Type Tests Test Description Test Levels Severity Levels Magnetic Field Enclosure 100 A/m Continuous   61000-4-8 Ports 1000 A/m for 1 s Pulse Magnetic Field Enclosure 300 A/m 61000-4-9 Ports Voltage Dips and Interrupts AC Power 30% for 0.5 Cycles  ...
  • Page 50 Certification 6.2 EMC and Environmental Type Tests Test Description Test Levels AC Power Ports ± 4 kV @ 2.5 kHz, 5 kHz Earth Ground Ports ± 4 kV IEEE 1613 Oscillatory Signal Ports 2.5 kV Common Mode @ 1 MHz DC Power Ports 2.5 kV Common Mode @ 1 MHz 1 kV Differential...
  • Page 51 Certification 6.2 EMC and Environmental Type Tests RUGGEDCOM RSG909R Installation Manual, 04/2023, C79000-G8976-1388-17...
  • Page 52 For more information Siemens RUGGEDCOM https://www.siemens.com/ruggedcom Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens Canada Ltd. Digital Industries Process Automation 300 Applewood Crescent Concord, Ontario, L4K 4E5 Canada © 2023 Siemens Canada Ltd. Subject to change...

This manual is also suitable for:

Simatic net ruggedcom rsg907r

Table of Contents