GE -DSH-73 User Manual page 121

Hide thumbs Also See for GE-DSH-73:
Table of Contents

Advertisement

X-Ring Configuration
The Managed Industrial Switch supports the function and interface for setting the
switch as the ring master or not. The ring master can negotiate and place command
to other switches in the X-Ring group. If there are 2 or more switches in master mode,
the software will select the switch with lowest MAC address number as the ring
master. The X-Ring master ring mode can be enabled by setting the X-Ring
configuration interface. Also, the user can identify whether the switch is the ring
master by checking the R.M. LED indicator on the panel of the Switch.
The system also supports the Couple Ring that can connect 2 or more X-Ring group
for the redundant backup function; Dual Homing function that can prevent
connection lose between X-Ring group and upper level/core switch.
Figure 5-62: X-Ring Interface
This page includes the following fields:
Object
Enable Ring:
GE-DSH-73/DSH-82 and DSH-82-PoE User Manual
Description
To enable the X-Ring function, tick the checkbox beside the Enable
Ring string label. If this checkbox is not ticked, all the ring functions
are unavailable.
Enable Ring Master: Tick the checkbox to enable this switch to be
the ring master.
1
& 2
Ring Ports: Pull down the selection menu to assign the
st
nd
Chapter 5: Web-Based Management
117

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ge-dsh-82Ge-dsh-82-poe

Table of Contents