Siemens SIMOVERT SLP Operating Instructions Manual

Simolink pulse generator

Advertisement

Quick Links

SIMOVERT MASTERDRIVES
Betriebsanleitung
Operating Instructions
SLP – SIMOLINK Puls Generator
SLP – SIMOLINK Pulse Generator
Ausgabe / Edition: AA
GWE-477 764 4070.76 J

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMOVERT SLP

  • Page 1 SIMOVERT MASTERDRIVES Betriebsanleitung Operating Instructions SLP – SIMOLINK Puls Generator SLP – SIMOLINK Pulse Generator Ausgabe / Edition: AA GWE-477 764 4070.76 J...
  • Page 2 However, the information in this document is regularly checked and necessary corrections will be included in subsequent editions. We are grateful for any recommendations for improvement. SIMOVERT® Registered Trade Mark © Siemens AG 2001 All rights reserved...
  • Page 3: Table Of Contents

    TECHNICAL DATA...................3-1 INSTALLATION ....................4-1 EMC measures....................4-1 Housing ......................4-1 CONNECTIONS ....................5-1 Connector X1.....................5-1 Encoder interface X2..................5-2 Fiber-optic cable connection ................5-5 START-UP ......................6-1 Setting the DIL switch..................6-1 LED displays......................6-2 SIMOLINK data interface ..................6-3 Siemens AG GWE-477 764 4070.76 J SIMOVERT MASTERDRIVES Operating Instructions...
  • Page 5: Definitions And Warnings

    NOTE For the purpose of this documentation, "Note" indicates important information about the product or about the respective part of the documentation which is essential to highlight. Siemens AG GWE-477 764 4070.76 J SIMOVERT MASTERDRIVES Operating Instructions...
  • Page 6 Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s purposes, the matter should be referred to the local SIEMENS sales office. The contents of this documentation shall not become part of or modify any prior or existing agreement, commitment or relationship.
  • Page 7 ♦ c = ESD shoes ♦ d = ESD overall ♦ e = ESD chain ♦ f = Cubicle ground connection Sitting Standing Standing / Sitting Fig. 1-1 ESD protective measures Siemens AG GWE-477 764 4070.76 J SIMOVERT MASTERDRIVES Operating Instructions...
  • Page 9: Product Description

    201 active nodes can be interconnected on the SIMOLINK ring. NOTE For further information about SIMOLINK, please refer to Chapter "Communication / SIMOLINK“ of the SIMOVERT MASTERDRIVES Compendium Motion Control, Order No.: 6SE7087-6QX50. Siemens AG GWE-477 764 4070.76 J SIMOVERT MASTERDRIVES Operating Instructions...
  • Page 10: Description Of Function

    The RS422 interface forms the desired signal levels which can be picked off on SUB D socket X2. The operating states are indicated by the three LEDs on the housing front panel. GWE-477 764 4070.76 J Siemens AG Operating Instructions SIMOVERT MASTERDRIVES...
  • Page 11: Technical Data

    Isolating voltage 500 V DC to 24 V voltage supply Fiber-optic cable connection Transmitter power Fixed (maximum transmitter power defined for SIMOLINK) Fiber-optic cable modules Hewlett Packard – Transmitter HFBR 1528 – Receiver HFBR 2528 Table 3-1 Technical data Siemens AG GWE-477 764 4070.76 J SIMOVERT MASTERDRIVES Operating Instructions...
  • Page 13: Installation

    The following diagrams show a schematic illustration of the housing and the layout of connections and operating elements. SIMOLINK PULS GENERATOR SLP SYNC POWER FREQ Front view Side view Fig. 4-1 Siemens AG GWE-477 764 4070.76 J SIMOVERT MASTERDRIVES Operating Instructions...
  • Page 14 Installation 02.2001 SIMOLINK Pulse Generator +24 V View from below Plan view Fig. 4-2 GWE-477 764 4070.76 J Siemens AG Operating Instructions SIMOVERT MASTERDRIVES...
  • Page 15: Connections

    +21 ... 28 V Connectable cross-section: 1.5 mm (AWG 16) Terminal 1 is the terminal to the rear of the module top plate (see plan view). Table 5-1 Connector assignments Siemens AG GWE-477 764 4070.76 J SIMOVERT MASTERDRIVES Operating Instructions...
  • Page 16: Encoder Interface X2

    Ground (see below) jumper to GND! 5, 6 n.c. Unused Housing Outer shield 9-pin SUB D socket with screw locking mechanism (UNC) Table 5-2 Assignment of connector X2 for 90° pulses mode GWE-477 764 4070.76 J Siemens AG Operating Instructions SIMOVERT MASTERDRIVES...
  • Page 17 SLP, the GND signal should not be connected; it must be noted in this respect that large deviations in the 0 V (GND) on different drives/devices can cause disturbances or malfunctions on the RS422 bus. Siemens AG GWE-477 764 4070.76 J SIMOVERT MASTERDRIVES Operating Instructions...
  • Page 18 The signal is low for positive setpoints and high for negative setpoints. Setpoint input Signal shape at output Track A Positive setpoint Track B Track A Negative setpoint Track B Fig. 5-4 Signal shape in 100 kHz signal mode GWE-477 764 4070.76 J Siemens AG Operating Instructions SIMOVERT MASTERDRIVES...
  • Page 19: Fiber-Optic Cable Connection

    If glass fiber optics are the selected medium, the connectors attached to the fiber-optic cable must be suitable, i.e. they must fit into the transmit and receive sockets on the SIMOLINK Pulse Generator. Siemens AG GWE-477 764 4070.76 J SIMOVERT MASTERDRIVES...
  • Page 20 8 about 25 times. Then clean the end again with a clean, lint-free cloth. € ó ì Cut fiber-optic Insert cable in Close cable to length connector connector Fig. 5-7 Connecting a plastic cable GWE-477 764 4070.76 J Siemens AG Operating Instructions SIMOVERT MASTERDRIVES...
  • Page 21: Start-Up

    NOTICE Address settings 201 to 255 are invalid, LEDs "SYNC“ and "FREQ“ flash alternately and no frequency is output. Siemens AG GWE-477 764 4070.76 J SIMOVERT MASTERDRIVES Operating Instructions...
  • Page 22: Led Displays

    An illuminated POWER LED does not necessarily confirm that the supply voltage level is correct. The operator is responsible for ensuring that the voltage supply remains stable within the specified limits. GWE-477 764 4070.76 J Siemens AG Operating Instructions SIMOVERT MASTERDRIVES...
  • Page 23: Simolink Data Interface

    NOTICE When the setpoint exceeds 112 %, the SIMOLINK Pulse Generator outputs the maximum frequency of approximately 28 kHz. If "100 kHz signal“ mode is active, then approximately 112 kHz. Siemens AG GWE-477 764 4070.76 J SIMOVERT MASTERDRIVES Operating Instructions...
  • Page 24 1500 1000 100.000 1500 1024 102.400 1500 2048 Not displayable 1) The speed range of the SLP cannot be output with this combination Table 6-4 Examples for 90° pulses mode GWE-477 764 4070.76 J Siemens AG Operating Instructions SIMOVERT MASTERDRIVES...
  • Page 25 If a time slot other than the time slot for setpoint calculation is used or the processing sequence altered, the resulting dead times will cause a lag in the signal output when the setpoint is changed. Siemens AG GWE-477 764 4070.76 J SIMOVERT MASTERDRIVES Operating Instructions...
  • Page 26 02.2001 Connections first edition 02.2001 Start-up first edition 02.2001 Group: Automation and Drives (A&D) Division: Variable-Speed Drive Systems Postfach 3269, D-91050 Erlangen Siemens Aktiengesellschaft Subject to change GWE-477 764 4070.76 Printed in the Federal Republic of Germany 02.2001...

This manual is also suitable for:

Simovert masterdrive series

Table of Contents