Industrial Division / Houston Motor Plant
REFERENCE USE ONLY WHEN ISSUED BY MOTOR MKTG.
Dist:
Mktg.
QC 1.
SCOPE
2.
START UP
Fig. 1
3.
STANDARD SERVICE
Motor Operation Procedure
Motor Lubrication
To give recommended guidelines for electric motor relubrication.
Toshiba motors are properly greased at the time of manufacture. It is recommended that
if a motor has been stored for a period of six months or more, it should be lubricated prior
to starting (See Fig. 1) using a standard hand held grease gun.
FRAME SIZE
143 ~ 256
284 ~ 405
444 and Larger
It should be noted that grease leakage around the shaft hole could indicated over-
packing. Excess grease should be purged out by operating the motor temporarily with
the relief open.
Lubrication of electric motors should be done as a part of a planned maintenance
program.
Before greasing, be sure fittings are clean and free from dirt. Always relubricate using
grease that is fresh and free from contamination.
Toshiba motors may be equipped with an automatic grease relief fitting, grease plug or
grease cover plate for the outlet.
It should be noted that it may be necessary to remove an automatic type fitting due to
hardening of grease. Motors utilizing a grease plate may require the scraping out of old
grease a minimum of once every two years.
1.
Select the proper service condition from Fig. 2.
2.
Select the frequency and volume from Fig. 3.
3.
Before greasing be sure fittings are clean and free from dirt.
INDEX
SHEET NO.
ISSUED
SUPERSEDES
REVISION
WRITTEN BY
APPROVED BY
QUANTITY of PUMPS
2 to 3 strokes
4 to 5 strokes
6 to 10 strokes
MDS-O-0001
1 of 3
01/24/96
NEW
0
I. MARQUEZ
J. Bugbee

Advertisement

loading

Summary of Contents for Toshiba Air Conditioner

  • Page 1 To give recommended guidelines for electric motor relubrication. START UP Toshiba motors are properly greased at the time of manufacture. It is recommended that if a motor has been stored for a period of six months or more, it should be lubricated prior to starting (See Fig.
  • Page 2 TOSHIBA INTERNATIONAL CORPORATION Industrial Division / Houston Motor Plant Motor Operation Procedure STANDARD SERVICE (-cont.) Remove relief plug or plate and using a low pressure hand held grease gun, pump the required amount of grease. For Frames 143T to 365T allow motor to run for 20 to 30 minutes and for Frames 405T and larger allow motor to run for 30 to 60 minutes before replacing hardware.
  • Page 3 Using the instructions for lubrication, open grease outlet and purge the system as much as possible of the old or unwanted grease. Repeat this same operation after 1 week of service. Consult TOSHIBA/HOUSTON Engineering for further recommendations on grease compatibility.