Siemens SINAMICS G130 Operating Instructions Manual page 15

Dv/dt filter compact plus voltage peak limiter
Hide thumbs Also See for SINAMICS G130:
Table of Contents

Advertisement

Table 2- 3
Max. pulse frequency when a dV/dt filter compact plus Voltage Peak Limiter is used in units with a rated pulse
frequency of 1.25 kHz
Order no. of the
Unit rating
Power Module
6SL3310-...
1GE36-1AAx
1GE37-5AAx
1GE38-4AAx
1GE41-0AAx
1GF31-8AAx
1GF32-2AAx
1GF32-6AAx
1GF33-3AAx
1GF34-1AAx
1GF34-7AAx
1GF35-8AAx
1GF37-4AAx
1GF38-1AAx
1GH28-5AAx
1GH31-0AAx
1GH31-2AAx
1GH31-5AAx
1GH31-8AAx
1GH32-2AAx
1GH32-6AAx
1GH33-3AAx
1GH34-1AAx
1GH34-7AAx
1GH35-8AAx
1GH37-4AAx
1GH38-1AAx
dV/dt filter compact plus Voltage Peak Limiter
Operating Instructions, 03/2011, A5E02590131A
Output current for a
[kW]
pulse frequency of 1.25 kHz [A]
Line voltage 380 V – 480 V 3 AC
315
400
450
560
Line voltage 500 V – 600 V 3 AC
110
132
160
200
250
315
400
450
560
Line voltage 660 V – 690 V 3 AC
75
90
110
132
160
200
250
315
400
450
560
710
800
compact plus Voltage Peak Limiter is used
605
745
840
985
175
215
260
330
410
465
575
735
810
85
100
120
150
175
215
260
330
410
465
575
735
810
Max. pulse frequency when a dV/dt filter
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz