  • Page 1 Introduction Safety notes Description SIMATIC NET Assembling Network components Transceiver SFP/SFP+/SCP/STP Uninstalling Connecting up Operating Instructions Technical data Dimension drawings Approvals 12/2017 A5E02630804-11...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Table of contents Introduction..............................5 Safety notes..............................9 Description..............................11 Type designation........................11 Product overview........................12 Components of the product....................14 Assembling..............................15 Notes on installation of SFP / SFP+ transceivers..............15 Using a pluggable transceiver (SFP/SFP+)................18 Notes on installation of SCP / STP transceivers..............18 Using a pluggable transceiver (SCP/STP)................20 Uninstalling..............................21 Removing a pluggable transceiver (SFP/SFP+)..............21 Removing a pluggable transceiver (SCP/STP)..............21...
  • Page 4 Table of contents 7.4.1 SCP992-1..........................33 7.4.2 SCP992-1LD..........................33 STP transceiver........................34 7.5.1 STP991-1..........................34 7.5.2 STP991-1LD..........................35 Attenuators..........................35 Construction...........................36 Environmental conditions.......................36 Effective power loss.......................36 7.10 MTBF (Mean Time Between Failure)..................37 Dimension drawings...........................39 SFP dimension drawing......................39 SFP+ dimension drawing.......................40 SCP dimension drawing......................41 STP dimension drawing......................42 Approvals..............................43 Index................................49 Transceiver SFP/SFP+/SCP/STP...
  • Page 5: Introduction

    ● On the data medium that ships with some products: – Product CD / product DVD – SIMATIC NET Manual Collection ● On the Internet pages of Siemens Industry Online Support: – Industrial Ethernet / PROFINET Industrial Ethernet System Manual (https:// support.industry.siemens.com/cs/ww/en/view/84922825)
  • Page 6 Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers’...
  • Page 7 Introduction To stay informed about product updates, subscribe to the Siemens Industrial Security RSS Feed under https://www.siemens.com/industrialsecurity (https://www.siemens.com/industrialsecurity) Transceiver SFP/SFP+/SCP/STP Operating Instructions, 12/2017, A5E02630804-11...
  • Page 8 Introduction Transceiver SFP/SFP+/SCP/STP Operating Instructions, 12/2017, A5E02630804-11...
  • Page 9: Safety Notes

    Safety notes Safety notices on the use of the devices The following safety notices must be adhered to when setting up and operating the device and during all associated work such as installation, connecting up, replacing devices or opening the device. Safety notices on use in hazardous areas General safety notices relating to protection against explosion WARNING...
  • Page 10 Safety notes WARNING If the temperature of the cable or housing socket exceeds 70 °C or the branching point of conductors exceeds 80 °C, special precautions must be taken. If the equipment is operated in an air ambient in excess of 50 °C to 70 °C, only use cables with a permitted operating temperature of at least 80 °C.
  • Page 11: Description

    Description Type designation Structure of the type designation The type designation of an pluggable transceiver is made up of several parts that have the following meaning: Standard version (C) Conformal coating Interface Number of ports 1 100 Mbps 2 1000 Mbps 3 10 Gbps SF Pluggable transceiver with LC connector SC Pluggable transceiver with SC connector...
  • Page 12: Product Overview

    Description 3.2 Product overview Product overview Note Fiber monitoring All pluggable transceivers are capable of diagnostics and support fiber monitoring. SFP transceiver Type Properties Article number SFP991-1 * 1 x 100 Mbps, LC port optical for glass FO cable 6GK5 991-1AD00-8AA0 (multimode), up to max.
  • Page 13 Description 3.2 Product overview Note Only the following transceivers are permitted for the SCALANCE W786-2 SFP: ● SFP992-1 ● SFP992-1LD ● SFP992-1LH ● SFP992-1LH+ ● SFP992-1ELH Bidirectional plug-in transceiver SFP Bidirectional plug-in transceivers feature only one fiber connection. They transmit and receive on two different wavelengths.
  • Page 14: Components Of The Product

    Description 3.3 Components of the product SCP / STP transceiver Type Properties Article number SCP992-1 1 x 1000 Mbps SC port optical for glass FO cable 6GK5 992-1AJ00-8AA0 (multimode) up to max. 750 m SCP992-1LD 1 x 1000 Mbps SC port optical for glass FO cable 6GK5 992-1AK00-8AA0 (single mode) up to max.
  • Page 15: Assembling

    Assembling Notes on installation of SFP / SFP+ transceivers General notes on media modules and pluggable transceivers WARNING Install and remove media modules only when the power is off Media modules may only be inserted in or removed from a SCALANCE device when the power supply to the device has been turned off.
  • Page 16: Approvals

    4.1 Notes on installation of SFP / SFP+ transceivers NOTICE Use only approved pluggable transceivers If you use components not approved by Siemens AG, in particular SFP / SFP+ transceivers, Siemens cannot accept any responsibility for the correct functioning of the "Ethernet switch system" according to the specification.
  • Page 17 Notes on SCALANCE W: Note With a SCALANCE W786-2, do not plug or pull an SFP transceiver during operation! If you have questions on the use of SIMATIC NET products, please contact your Siemens sales partner. Transceiver SFP/SFP+/SCP/STP Operating Instructions, 12/2017, A5E02630804-11...
  • Page 18: Using A Pluggable Transceiver (Sfp/Sfp+)

    General notes on pluggable transceivers NOTICE Use only approved pluggable transceivers If you use components not approved by Siemens AG, in particular SCP / STP transceivers, Siemens cannot accept any responsibility for the correct functioning of the "Ethernet switch system" according to the specification.
  • Page 19 Notes on SCALANCE W: Note With a SCALANCE W786-2, do not plug or pull an SFP transceiver during operation! If you have questions on the use of SIMATIC NET products, please contact your Siemens sales partner. Transceiver SFP/SFP+/SCP/STP Operating Instructions, 12/2017, A5E02630804-11...
  • Page 20: Using A Pluggable Transceiver (Scp/Stp)

    Assembling 4.4 Using a pluggable transceiver (SCP/STP) Using a pluggable transceiver (SCP/STP) Figure 4-2 Plugging in a transceiver Follow the steps below to insert a pluggable transceiver: 1. Remove the sealing plug of the pluggable transceiver. 2. Hold the pluggable transceiver so that the slight protrusion is on the right, see figure. 3.
  • Page 21: Uninstalling

    Uninstalling Removing a pluggable transceiver (SFP/SFP+) Notes on deinstallation CAUTION Risk of burns due to the high temperatures of the pluggable transceiver The pluggable transceivers can be plugged and pulled during operation. Leave the transceiver to cool down as much as possible. Procedure Follow the steps below to remove a pluggable transceiver: 1.
  • Page 22 Uninstalling 5.2 Removing a pluggable transceiver (SCP/STP) Procedure Figure 5-1 Removing a pluggable transceiver Follow the steps below to remove a pluggable transceiver: 1. Remove the connecting cable of the pluggable transceiver. 2. Press the spring in the transceiver slot to the right using a screwdriver, see figure. The transceiver is pushed part of the way out of the transceiver slot.
  • Page 23: Connecting Up

    Connecting up NOTICE Failure of the data traffic due to contamination of optical plug-in connections Optical sockets and plugs are sensitive to contamination of the end face. Contamination can lead to the failure of the optical transmission network. Close unused optical sockets and plugs as well as pluggable transceivers and slots with the supplied protective caps.
  • Page 24 Connecting up 6.1 Power supply Transceiver SFP/SFP+/SCP/STP Operating Instructions, 12/2017, A5E02630804-11...
  • Page 25: Technical Data

    Technical data SFP transceiver LC connector technology The attachment to Industrial Ethernet uses LC connector technology (Lucent Connector). Pluggable transceiver slot/ plugged in transceiver 7.1.1 SFP991-1/SFP991-1(C) Properties Transmission mode 100Base-FX complying with IEEE 802.3 Transmission rate 100 Mbps (Fast Ethernet) Transmission medium Multimode fiber-optic cable Light source...
  • Page 26: Sfp991-1Ld/Sfp991-1Ld(C)

    Technical data 7.1 SFP transceiver 7.1.2 SFP991-1LD/SFP991-1LD(C) Properties Transmission mode 100Base-LX complying with IEEE 802.3 Transmission rate 100 Mbps (Fast Ethernet) Transmission medium Single mode fiber-optic cable Light source Class1-LASER "Eye safe" Wavelength 1310 nm Cable length (max.) * 26 km Transmitter output (optical) Minimum -15 dBm...
  • Page 27: Sfp992-1

    Technical data 7.1 SFP transceiver Properties Transmission medium Single mode fiber-optic cable Light source Class1-LASER "Eye safe" Wavelength 1550 nm Cable length (max.) * 200 km Transmitter output (optical) Minimum 1 dBm Maximum 5 dBm Receiver input Sensitivity min. -42 dBm Input power max.
  • Page 28: Sfp992-1Ld/Sfp992-1Ld(C)

    Technical data 7.1 SFP transceiver Properties Cable length (max.) * At 50 µm fiber core diameter 2 km At 62.5 µm fiber core diameter 1 km Transmitter output (optical) Minimum -15 dBm Maximum -1 dBm Receiver input Sensitivity min. -23 dBm Input power max.
  • Page 29: Sfp992-1Lh

    Technical data 7.1 SFP transceiver Properties Receiver input Sensitivity min. -23 dBm Input power max. -3 dBm Depending on the cable used, you can find additional information in the "Industrial Ethernet / PROFINET Passive network components" System Manual, see also section "Introduction", paragraph "Additional documentation".
  • Page 30: Bidirectional Plug-In Transceiver Sfp

    Technical data 7.2 Bidirectional plug-in transceiver SFP Bidirectional plug-in transceiver SFP LC connector technology (bidirectional) The attachment to Industrial Ethernet uses LC connector technology (Lucent Connector) with a fiber connection. Pluggable transceiver slot/ plugged in transceiver 7.2.1 SFP992-1BXMT Properties Transmission mode 1000Base-BX Transmission rate 1000 Mbps (Gigabit Ethernet)
  • Page 31: Sfp+ Transceiver

    Technical data 7.3 SFP+ transceiver Properties Transmitter output (optical) Minimum -10 dBm Maximum -4 dBm Receiver input Sensitivity min. -17 dBm Input power max. -3 dBm Depending on the cable used, you can find additional information in the "Industrial Ethernet / PROFINET Passive network components"...
  • Page 32: Sfp993-1Ld

    Technical data 7.3 SFP+ transceiver 7.3.2 SFP993-1LD Properties Transmission mode 10GBASE-LR complying with IEEE 802.3 Transmission rate 10 Gbps (10 Gigabit Ethernet) Transmission medium Single mode fiber-optic cable Light source Class1-LASER "Eye safe" Wavelength 1310 nm Cable length (max.) * 10 km Transmitter output (optical) Minimum...
  • Page 33: Scp Transceiver

    Technical data 7.4 SCP transceiver SCP transceiver SC connectors The attachment to Industrial Ethernet uses SC connector technology (Subscriber Connector). 7.4.1 SCP992-1 Properties Transmission mode 1000Base-SX complying with IEEE 802.3 Transmission rate 1000 Mbps (Gigabit Ethernet) Transmission medium Multimode fiber-optic cable Light source Class1-LASER "Eye safe"...
  • Page 34: Stp Transceiver

    Technical data 7.5 STP transceiver Properties Receiver input Sensitivity min. -21 dBm Input power max. -3 dBm Depending on the cable used, you can find additional information in the "Industrial Ethernet / PROFINET Passive network components" System Manual, see also section "Introduction", paragraph "Additional documentation".
  • Page 35: Stp991-1Ld

    Technical data 7.6 Attenuators 7.5.2 STP991-1LD Properties Transmission mode 100Base-LX complying with IEEE 802.3 Transmission rate 100 Mbps (Fast Ethernet) Transmission medium Single mode fiber-optic cable Light source Class1-LASER "Eye safe" Wavelength 1310 nm Cable length (max.) * 26 km Transmitter output (optical) Minimum -15 dBm...
  • Page 36: Construction

    Technical data 7.9 Effective power loss Construction Construction SFP/SFP+ Dimensions (W x H x D) 14 x 9 x 57 mm Weight 20 g SCP/STP Dimensions (W x H x D) 28 x 9 x 57 mm Weight 60 g Environmental conditions Environmental conditions Transportation/storage temperature...
  • Page 37: Mtbf (Mean Time Between Failure)

    Technical data 7.10 MTBF (Mean Time Between Failure) Effective power loss at 25 °C ambient temperature SCP992-1 0.33 W SCP992-1LD 0.41 W STP991-1 0.36 W STP991-1LD 0.39 W Note Fusing of transceivers The pluggable transceivers (SFP/SFP+/SCP/STP) do not have fuses. The fuse is in the modular device.
  • Page 38 Technical data 7.10 MTBF (Mean Time Between Failure) Transceiver SFP/SFP+/SCP/STP Operating Instructions, 12/2017, A5E02630804-11...
  • Page 39: Dimension Drawings

    Dimension drawings SFP dimension drawing Front and top view, side view (left/right) and view from below Dimensions are specified in mm. Transceiver SFP/SFP+/SCP/STP Operating Instructions, 12/2017, A5E02630804-11...
  • Page 40: Sfp+ Dimension Drawing

    Dimension drawings 8.2 SFP+ dimension drawing SFP+ dimension drawing Front and top view, side view (left/right) and view from below Dimensions are specified in mm. Transceiver SFP/SFP+/SCP/STP Operating Instructions, 12/2017, A5E02630804-11...
  • Page 41: Scp Dimension Drawing

    Dimension drawings 8.3 SCP dimension drawing SCP dimension drawing Front and top view, side view (left/right) and view from below Dimensions are specified in mm. Transceiver SFP/SFP+/SCP/STP Operating Instructions, 12/2017, A5E02630804-11...
  • Page 42: Stp Dimension Drawing

    Dimension drawings 8.4 STP dimension drawing STP dimension drawing Front and top view, side view (left/right) and view from below Dimensions are specified in mm. Transceiver SFP/SFP+/SCP/STP Operating Instructions, 12/2017, A5E02630804-11...
  • Page 43: Approvals

    Approvals The SIMATIC NET products described in these Operating Instructions have the approvals listed below. Note Issued approvals on the type plate of the device The specified approvals apply only when the corresponding mark is printed on the product. You can check which of the following approvals have been granted for your product by the markings on the type plate.
  • Page 44 "SIMATIC NET Product Information Use of subasseblies/modules in a Zone 2 Hazardous Area". You will find this document ● on the data medium that ships with some devices. ● on the Internet pages of Siemens Industry Online Support (https:// support.industry.siemens.com/cs/ww/en/ps). Enter the document identification number C234 as the search term.
  • Page 45 Approvals KEMA 07ATEX0145 X The products meet the requirements of the following standards: ● EN 60079-15 (electrical apparatus for potentially explosive atmospheres; Type of protection "n") ● EN 60079-0 (Explosive atmospheres - Part 0: Equipment - General requirements) You will find the current versions of the standards in the currently valid ATEX certificates. IECEx The SIMATIC NET products meet the requirements of explosion protection according to IECEx.
  • Page 46 Approvals FDA and IEC marks The following devices meet the FDA and IEC requirements listed below: Pluggable transceiv‐ Type Fulfills FDA and IEC requirements SFP991-1 CLASS 1 LASER PRODUCT SFP991-1LD CLASS 1 LASER PRODUCT SFP991-1LH+ CLASS 1 LASER PRODUCT SFP991-1ELH200 CLASS 1 LASER PRODUCT SFP992-1 CLASS 1 LASER PRODUCT...
  • Page 47 ● "Industrial Ethernet / PROFINET Industrial Ethernet" System Manual (https:// support.industry.siemens.com/cs/ww/en/view/84922825) ● "Industrial Ethernet / PROFINET - Passive Network Components" System Manual (https:// support.industry.siemens.com/cs/ww/en/view/27069465) ● "EMC Installation Guidelines" configuration manual (https://support.industry.siemens.com/...
  • Page 48 Approvals Note The test was performed with a device and a connected communications partner that also meets the requirements of the standards listed above. When operating the device with a communications partner that does not comply with these standards, adherence to the corresponding values cannot be guaranteed. Transceiver SFP/SFP+/SCP/STP Operating Instructions, 12/2017, A5E02630804-11...
  • Page 49: Index

    Index Article number, 12, 13, 14 Attenuation, 35 Attenuator, 35 Fiber monitoring, 12 Glossary, 6 Pluggable transceiver Inserting, 18, 20 Notes on deinstallation, 21 Removing, 21, 22 SCP, 14 STP, 14 Pluggable transceiver slot, 21 Power supply, 23 Safety instructions, 9 SCP transceiver, 14 SCP/STP transceiver Notes on installation, 18...
  • Page 50 Index Transceiver SFP/SFP+/SCP/STP Operating Instructions, 12/2017, A5E02630804-11...

Table of Contents