Download Print this page

Maintenance; Troubleshooting - Sealey PBI2212S Instructions

Roadstart emergency power packs dekra approved

Advertisement

5.2
Powering a 12V DC Device:
The RoadStart is a power source for all 12V DC accessories that are equipped with a 12V accessory plug. Make sure the device
to be powered is OFF before inserting the 12V DC accessory plug into the 12V DC accessory outlet.
5.2.1
Open the protective cover of the DC power outlet on the front of the RoadStart.
5.2.2. Plug the device into the outlet and turn the device on (if required).
5.2.3. If the device draws more than 15A or has a short circuit, the internal circuit breaker of the RoadStart will trip and disconnect the power
to the device. Disconnect the device and the breaker will automatically reset.
The DC power outlet is wired directly to the internal battery. Extended operation of a 12V device may result in excessive battery drain.
Recharge immediately after unplugging the device.

6. MAINTENANCE

6.1.
Charger Maintenance Instructions
6.1.1. Unplug the charger from the RoadStart before attempting any maintenance or cleaning.
6.1.2. Use a dry cloth to wipe dirt or oil from the charger. Do not use cleaning fluids.
6.1.3. All other servicing should be performed by qualified personnel.
6.1.4. If the supply cord is damaged, it must be replaced. Contact your Sealey service agent.
6.2.
Fuse Replacement For The RoadStart
The RoadStart is equipped with an external fuse to protect the battery from overload.
WARNING Disconnect the charger unit from mains supply.
6.2.1. To replace the fuse if it has blown, use a flat bladed screwdriver to gently push in the fuse cover release clips at each end, to release
the cover.
6.2.2. Undo the two 13mm nuts and replace the fuse.
6.2.3. Refit the cover.

7. TROUBLESHOOTING

Problem
The RoadStart won't jump start the vehicle.
The RoadStart won't power a device.
The battery in the RoadStart won't hold a
charge.
RoadStart shows 100% charge, but charger
charging (amber LED).
© Jack Sealey Ltd
RoadStart
Possible Cause
Clamps are not making a good connection.
The RoadStart battery is not charged.
The vehicle's battery is defective.
The external (500A) fuse has blown.
The 12V device is not turned on.
The RoadStart battery is not charged.
The 12V device draws more than 15A or has
a short circuit.
The battery is faulty (will not accept a charge). Have the battery checked.
Unit needs more charge.
Original Language Version
Solution
Check for poor connection to battery and to the
chassis. Make sure connection points are
clean. Rock clamps back and forth for a
connection.
Check the battery charge status by pressing
the button on the front of the RoadStart.
See section 4 of this manual.
Have the battery checked.
Replace the fuse, (see section 6.2).
Turn on the 12V device.
Check the battery charge status by
pressing the button on the front of the
RoadStart. See section 4 of this manual.
Disconnect the 12V device. The internal
breaker will automatically reset after a
minute or two. Try the 12V device again. If it
happens again, replace the 12V device.
Charge RoadStart until the charger's 'charged'
green LED comes on.
PBI2212S,PBI3612S,PBI3624S,PBI4424S
Issue: 1 - 06/05/14

Advertisement

loading

This manual is also suitable for:

Pbi3612sPbi3624sPbi4424s