Download Print this page

Sealey PBI2212S Instructions page 5

Roadstart emergency power packs dekra approved

Advertisement

Problem
CHECK BATTERY (red) LED on charger
is on.
CHECK BATTERY (red) LED is flashing.
Parts support is available for this product. To obtain a parts listing and/or diagram,
please log on to www.sealey.co.uk, email sales@sealey.co.uk or telephone
Environmental Protection.
Recycle unwanted materials instead of disposing of them as
waste. All tools, accessories and packaging should be sorted,
taken to a recycle centre and disposed of in a manner which
is compatible with the environment.
NOTE: The RoadStart battery is a sealed, lead-acid type. By law, it must be removed and recycled, or disposed of properly,
according to national and/ or local regulations.
1. Place the RoadStart unit front side down.
2. Remove the screws from the rear panel and lift off from the unit enclosure.
3. Disconnect the wires from the two battery terminals, taking care to avoid accidental arcing of the terminals.
4. Lift the battery (batteries) out of the casing.
Disposal
Take the battery to a recycling centre that handles sealed, lead-acid batteries.
If there is no recycling centre in the area, contact the local environmental agency for disposal instructions.
Under the Waste Batteries and Accumulators Regulations 2009, Jack Sealey Ltd are required to inform potential purchasers of
products containing batteries (as defined within these regulations), that they are registered with Valpak's registered compliance
scheme. Jack Sealey Ltd's Batteries Producer Registration Number (BPRN) is BPRN00705.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
© Jack Sealey Limited
Charger
Possible Cause
Charger is not making a good connection
to the Roadstart.
Battery is defective (will not accept a charge.)
Indicates charger is in abort mode.
01284 757500.
Battery Removal
Sole UK Distributor, Sealey Group,
Kempson Way, Suffolk Business Park,
Bury St. Edmunds, Suffolk,
IP32 7AR
Original Language Version
Solution
Check the connection. Make sure the
connection points are clean.
Have the battery checked.
See Section 4.8.
WEEE Regulations.
Dispose of this product at the end of its working life in compliance
with the EU Directive on Waste Electrical and Electronic Equipment.
When the product is no longer required, it must be disposed of in an
environmentally protective way. Contact your local solid waste
authority for recycling information.
01284 757500
01284 703534
PBI2212S,PBI3612S,PBI3624S,PBI4424S
www.sealey.co.uk
sales@sealey.co.uk
Issue: 1 - 06/05/14

Advertisement

loading

This manual is also suitable for:

Pbi3612sPbi3624sPbi4424s