7-8
DC Bus Capacitor Unit HLC01.1
Graphic Representation
Tightening Torque
Tightening Torque
DC Bus Wiring
X1, Bus Module
The bus module permits data exchange between the devices. At the DC
bus capacitor unit the bus module is looped through to other devices
without influencing the data.
Note:
Abandon on connecting the bus module, if the DC bus
capacitor unit is the last device in the row of devices.
Fig. 7-8:
X1
Design
Type
Flat line connector
Flat line bushing
Fig. 7-9:
Design
Control Voltage (+24 V, 0 V)
The control voltage supply is connected by contact rails and screws (M6)
Design
to the front of the drive. At the DC bus capacitor unit the control voltage is
looped through to other devices. The DC bus capacitor unit itself needs
no control voltage. The contact rails are parts of our accessories
HAS01.1-xxx-072-MN.
Note:
Abandon on connecting the control voltage, if the DC bus
capacitor unit is the last device in the row of devices.
6 Nm
DC Bus (L+, L-)
The DC bus is connected by contact rails and screws (M6) to the front of
Design
the device. The contact rails are parts of our accessories HAS01.1-xxx-
072-MN.
6 Nm
If in special cases it is not possible to use the DC bus rails provided to
make the connection, the connection must be made using the shortest
possible twisted cables.
Rexroth IndraDrive
X1f2.FH7
Number of
Type of design
poles
8
Connector on device
8
Bushing on flat line
DOK-INDRV*-ADDCOMP****-PR02-EN-P