Servicing; Size And Capacity Of Propane Cylinders Required - Craftsman CMXEHAO60FAV Instruction Manual

This is an unvented portable heater. it uses air (oxygen) from the area in which it is used. adequate combustion and ventilation air must be provided. refer propane forced-air heater
Table of Contents

Advertisement

Available languages

Available languages

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
RESTART AFTER SAFETY SHUTDOWN
1.
Securely close valve at propane cylinder. Unplug heater.
2.
Wait 5 minutes.
3.
Restart following "Start" procedure.
MAINTENANCE AND STORAGE
1.
The heater should be inspected before each use, and at least
annually by a qualified person.
2.
Before each use, check the soft "O" ring seal at the bullnose of the
POL fitting. If the "O" ring is cut, scuffed, or otherwise damaged,
replace it with part number
F273786.
3.
Turn off the gas at the LP-gas supply cylinder(s) when the heater is
not in use.
4.
When the heater is to be stored indoors, the connection between
the LP-gas supply cylinder(s) and the heater must be disconnected
and the cylinder(s) removed from the heater and stored out of
doors and in accordance with Chapter 5 of the standard for Storage
and Handling of Liquefied Petroleum Gases ANSI/NFPA 58 and CSA
B149.1, Natural Gas and Propane Installation Code.

SERVICING

A hazardous condition may result if a heater is used that has been
modified or is not functioning properly. When the heater is working
properly:
The flame is contained within the heater.
The flame is essentially blue with perhaps some yellow tipping.
There is no strong disagreeable odor, eye burning or other physical
discomfort.
There is no smoke or soot internal or external to the heater.
There are no unplanned or unexplained shut downs of the heater.
The parts lists and wiring diagram show the heater as it was constructed.
Do not use a heater which is different from that shown. In this regard,
use only the hose, regulator and cylinder connection fitting (called a
POL fitting) supplied with the heater.
stripe on the hang tag attached to the hose assembly with the color on
the label located near the propane inlet fitting on the heater. Do not
use alternates. For this heater, the regulator must be set as shown in
"specifications". If there is any uncertainty about the regulator setting,
have it checked.
A heater which is not working right must be repaired, but only by a
trained, experienced service person.
In-warranty products will be repaired with no charge for either parts or
labor. Please include a brief statement indicating date, place of purchase,
the nature of the problem and proof of purchase.
Out of warranty products will be repaired with a charge for parts and
labor.
HEATER ELEVATION ADJUSTMENT
This heater is equipped with an elevation adjustment panel located at
the exhaust end of the control box.
1.
Do not adjust the heater combustion tube elevation while heater is
running or hot. Adjustments to elevation should only be made after
the heater has cooled to touch.
2.
To adjust the heater combustion tube elevation, turn the
adjustment screw knob counterclockwise and lift the combustion
tube to desired position.
CRAFTSMAN, Inc. | Forced Air Propane Construction Heater
IMPORTANT
: Match the color

SIZE AND CAPACITY OF PROPANE CYLINDERS REQUIRED

The charts below show the approximate size of the cylinder required for
these heaters. To use the chart:
1. Select the lowest air temperature expected (at the bottom of the
chart).
2. Move straight up to time of operation desired (left side of chart).
3. Read the cylinder size required.
All heaters should have:
full cylinders
good air circulation
no frost on cylinders
60,000 BTU/HR (16.1kW)
28
26
24
22
20
18
16
14
12
10
8
6
4
2
60
40
(16)
(4.4)
AIR TEMPERATURE - ºF (ºC)
125,000 BTU/HR (49.1kW)
3 CYLINDERS
40
100# (45.4KG
38
36
34
32
30
2 CYLINDERS
28
100# (45.4KG
26
24
22
20
18
16
14
1 CYLINDERS
12
100# (45.4KG
10
8
6
4
2
60
40
(16)
(4.4)
AIR TEMPERATURE - ºF (ºC)
5
Operator's Manual
20
0
-20
(-6.7)
(-18)
(-29)
USE WITH LIQUID
DRAWL AND A
VAPORIZER
20
0
-20
(-6.7)
(-18)
(-29)