Dell C Series Quick Start Manual page 10

Systems
Hide thumbs Also See for C Series:
Table of Contents

Advertisement

WARNING: The C7008/C300 and C7004/C150 operates in either of two
voltage ranges. The different power supply configuration supported is listed in
the following table. As a safety precaution, do not install more than the
recommended maximum number of PSUs (shown below), as this causes high
leakage current. Install blank panels in all unused PSU slots.
Voltage
C7004/C150 100-120
200-240
C7008/C300 100-120
200-240
Step
Task
Verify the power switch is in the OFF (left) position.
1
Secure the retaining latch in the unlatched position by tightening the
2
screw into the threaded hole.
Slide the power supply into the top left-most power supply slot.
3
Dell Networking recommends installing power supplies starting from
the left side, top row of the chassis, leaving no blank slots between units.
Lower the retaining latch, and tighten it into place.
4
Plug the AC power cord into the power receptacle in the face of the
5
power supply.
Plug the power cord into an AC power outlet.
6
NOTE: The higher power of power over Ethernet plus (PoE+) (30W/port) is
available only with Power Supply 1600W-AC and the PoE+ line card. When using
the PoE line card or PoE+ line card and the Power Supply 1200W-AC, only
15.4W/port power is available. The maximum power per port is listed in the
following table.
Power Supply
1200W-AC
PoE line card
15.4W/port
PoE+ line card 15.4W/port
10
Installing the Hardware
Frequency
50/60Hz
50/60Hz
50/60Hz
50/60Hz
Power Supply
1600W-AC at
lowline (100-120V)
15.4W/port
30W/port
Maximum PSUs
5 primary + 1 redundant
5 primary + 1 redundant
7 primary + 1 redundant
7 primary + 1 redundant
Power Supply
1600W-AC at
highline (200-240V)
15.4W/port
30W/port

Advertisement

Table of Contents
loading

This manual is also suitable for:

C7004C7008

Table of Contents