Download Print this page
Huawei SDongleA-03 Quick Manual
Hide thumbs Also See for SDongleA-03:

Advertisement

Quick Links

SDongleA-03 Quick Guide (4G)
Document Issue: 08
Part Number: 31509550
Release Date: 2019-09-30
The information in this document is subject to change without notice. Every
effort has been made in the preparation of this document to ensure accuracy of
the contents, but all statements, information, and recommendations in this
document do not constitute a warranty of any kind, express or implied. You can
download this document by scanning the QR code.
• SDongleA-03 Smart Dongle (the "Dongle" for short) is a smart communications expansion module
that works with Huawei inverters to implement wireless communication between inverters and
management systems through the 4G network.
• The Smart Dongle can be used for the RS485 device cascading (inverter cascading or inverter
cascading with other devices). For the SUN2000-2KTL/3KTL/4KTL/5KTL-L0, only one inverter can
be connected.
• When multiple inverters are cascaded, only one Smart Dongle or one SmartLogger is allowed.
Application Scenario of the SUN2000-(3KTL–20KTL)
As the Master Inverter
1
Communication Scenario
NOTE
Inverters with different appearances are used in the same communication scenario. The
inverters in this document are used as an example.
The inverter models are subject to change. The models listed in this document are for reference
only.
Master
inverter
Slave
inverter 1
Slave
inverter N
2
Installation and Commissioning
1. Install a SIM card.
NOTE
• You need to prepare a standard SIM card (size: 25 mm x 15 mm; capacity: ≥ 64 KB). When
connecting to Huawei Hosting Cloud, prepare a SIM card based on the traffic requirements in
the following table.
• Before installing a SIM card, you need to remove the Dongle from an inverter.
Monthly Traffic Requirement of SIM Cards
Inverters
With Smart PV
Optimizers
With Smart Power
Sensor
2. Install the Dongle.
Inverter USB port
LED
Color
Status
N/A
Off
Yellow (blinking
green and red
Steady on
simultaneously)
Green
Blinking in a 2-second
cycle (on for 0.1s and
then off for 1.9s)
Blinking at long
intervals (on for 1s and
then off for 1s)
Steady on
Blinking at short
intervals (on for 0.2s
and then off for 0.2s)
Red
Steady on
Blinking at short
intervals (on for 0.2s
and then off for 0.2s)
Blinking at long
intervals (on for 1s and
then off for 1s)
Blinking red and
green
Blinking at long
alternatively
intervals (on for 1s and
then off for 1s)
3.
Install the FusionSolar app (2.3.5 or later) and perform Setup Wizard. For details, see the
corresponding FusionSolar App Quick Guide. You can download the document by scanning
the Quick Guide QR code. If the operation has been performed, ignore it.
Method 1: Search for FusionSolar in Google Play and install the app.
Method 2: Scan the QR code to download and install the app.
FusionSolar
NOTE
In Britain, only the FusionHome app can
be used for commissioning.
To obtain the FusionHome App, scan the
QR code or search for FusionHome in
Google play to download and install the
app. The app version is 3.1.00.005 or
later.
Application Scenario of a Commercial Smart Inverter
As the Master Inverter
1
Communication Scenario
Master
inverter
Slave
inverter 1
Slave
inverter N
In RS485 cascading networking, the master inverter can be: SUN2000-70KTL/75KTL-C1 (optional),
SUN2000-50KTL/63KTL-JPM0, SUN2000-50KTL-JPM1,
SUN2000-50KTL/60KTL/65KTL/100KTL/110KTL/125KTL-M0, SUN2000-70KTL/100KTL-INM0,
SUN2000-100KTL-M1, SUN2000-175KTL-H0, SUN2000-185KTL-INH0, and SUN2000-185KTL-H1;
The slave inverters can be: SUN2000-29.9KTL/36KTL/42KTL/50KTL, SUN2000-33KTL-A,
SUN2000-33KTL/40KTL-JP, SUN2000-43KTL-IN-C1, SUN2000-50KTL/70KTL/75KTL-C1,
SUN2000-50KTL/63KTL-JPM0, SUN2000-50KTL-JPM1,
SUN2000-50KTL/60KTL/65KTL/100KTL/110KTL/125KTL-M0, SUN2000-70KTL/100KTL-INM0,
SUN2000-100KTL-M1, SUN2000-175KTL-H0, SUN2000-185KTL-INH0, and SUN2000-185KTL-H1.
2
Installation and Commissioning
NOTE
If the SIM card of the Dongle has a PIN code, install the Dongle first. Otherwise, skip the first
step. You can obtain the PIN code from the carrier.
When connecting to the Huawei FusionSolar management system, you do not need to set
parameters for connecting inverters to the management system on the SUN2000 app.
Installing the Dongle (Optional)
2.1
1. Install a SIM card.
NOTE
• You need to prepare a standard SIM card (size: 25 mm x 15 mm; capacity: ≥ 64 KB). When
connecting to Huawei Hosting Cloud, prepare a SIM card based on the traffic requirements in
the following table.
• Before installing a SIM card, you need to remove the Dongle from an inverter.
Monthly Traffic Requirement of SIM Cards
Inverters
With power
meters
With the
weather station
2. Install the Dongle.
Inverter USB port
3.
When the LED indicator is green and blinks in a 2-second cycle (on for 0.1s and then off for
1.9s), remove the Dongle.
Setting Inverter Parameters at the Local Router Using
2.2
the SUN2000 App
Before setting parameters, ensure that the following conditions are met:
1. To obtain the SUN2000 App, scan the QR code or search for SUN2000
in Google play to download and install the app. The app version is
3.2.00.001 (Android) or later.
2.
Ensure that the AC or DC side of the inverter has been powered on.
3.
Connect the Bluetooth model, WLAN model or USB data cable to the
inverter USB port to ensure that inverters can communicate with the
SUN2000 app.
The following describes how to set the SUN2000 app (3.2.00.001) on the
Android UI.
Bluetooth/WLAN Connection
Inverter USB port
Log in to the SUN2000 app as Advanced User, set basic parameters for the master inverter on
1.
the Quick settings screen, and synchronize some parameters of the master inverter to the
slave inverters on the PV plant configuration screen.
NOTE
When the WLAN connection is used, the initial name of the WLAN hotspot is Adapter-WLAN
module SN, and the initial password is Changeme.
Use the initial password upon first power-on and change it immediately after login. To
ensure account security, change the password periodically and keep the new password in
mind. Not changing the initial password may cause password disclosure. A password left
unchanged for a long period of time may be stolen or cracked. If a password is lost, devices
cannot be accessed. In these cases, the user is liable for any loss caused to the PV plant.
If you log in to the SUN2000 app after the device connects to the app for the first time or
factory defaults are restored, the Quick settings screen is displayed. If the Quick settings
screen is not displayed, you can set basic inverter parameters under Grid Parameters,
User Parameters, and Comm. Parameters on the Settings screen.
SUN2000 app login
initial password: 00000a
Copyright © Huawei Technologies Co., Ltd. 2019. All rights reserved.
FusionSolar app
Devices in the
dashed box are
optional.
In the RS485 cascading communication networking, the slave
inverter model can be SUN2000-(3KTL–20KTL)-M0,
SUN2000-50KTL/60KTL/65KTL-M0, SUN2000-
29.9KTL/36KTL, or SUN2000-33KTL-A.
10 MB + 4 MB x Number of
inverters
2 MB + 0.2 MB x Number of
Smart PV Optimizers
3 MB x Number of Smart Power
Sensor
Install the SIM
card in the arrow
direction.
SUN2000 app
Number of devices in the RS485 communication scenario
Devices in
Maximum number
the dashed
box are
can be connected
optional.
10
10 MB + 4 MB x Number
of inverters
3 MB x Number of power
meters
3 MB x Number of weather
stations
Install the SIM
card in the arrow
direction.
Android
Number of devices in the
RS485 communication scenario
Limited Number
Maximum number
of devices that can
be connected to
the Dongle
10
Remarks
Description
Normal
The Dongle is not secured or is not powered on.
The Dongle is secured and powered on.
Normal
Dialing (duration < 1 min)
Abnormal If the duration is longer than 1 min, the 4G
parameter settings are incorrect. Reset the
parameters.
Normal
The dial-up connection is set up successfully
(duration < 30s).
Abnormal If the duration is longer than 30s, the settings of
the management system parameters are
incorrect. Reset the parameters.
Normal
Successfully connected to the management
system.
The inverter is communicating with the
management system through the Dongle.
Abnormal The Dongle is faulty. Replace Dongle.
The Dongle has no SIM card or the SIM card is
in poor contact. Check whether the SIM card
has been installed or is in good contact. If not,
install the SIM card or remove and insert the
SIM card.
The Dongle fails to connect to the management
system because it has no signals, weak signal,
or no traffic. If the Dongle is reliably connected,
check the SIM card signal through the APP. If
no signal is received or the signal strength is
weak, contact the carrier. Check whether the
tariff and traffic of the SIM card are normal. If
not, recharge the SIM card or buy traffic.
No communication with the inverter
Remove and insert the Dongle.
Check whether inverters match the Dongle.
Connect the Dongle to other inverters.
Check whether the Dongle or the USB port
of the inverter is faulty.
Google Play
Limited Number
of devices that
to the Dongle
NOTE
The inverter models are subject to change. The models
listed in this document are for reference only.
For details about communication scenario, see the
Distributed PV Plants Connecting to Huawei Hosting
Cloud User Manual (Commercial Inverters + SDongleA
+ RS485 Networking Scenario).
Device performance data can be refreshed
every 5 minutes.
The Dongle logs, inverter logs, and IV
diagnosis data can be exported monthly. The
Dongle and inverters can be upgraded
monthly.
Management system
Actual Number
Number of other
Number of
devices (such as
slave
Smart Power Sensor
inverters
and energy storage
N ≤ 9
≤ 9 – N
Traffic Support
• Device performance data can be
refreshed every 5 minutes.
• The Dongle logs, inverter logs, and IV
diagnosis data can be exported
monthly. The Dongle and inverters can
be upgraded monthly.
Ensure that the Dongle
shell is properly
installed.
LED
Quick Guide
Google play
Management
system
Actual Number
Number of other devices
Number
(such as power meters
of slave
and energy storage
inverters
N ≤ 9
≤ 9 – N
Traffic Support
Ensure that the Dongle
shell is properly
installed.
LED
USB Connection
devices)
devices)
SUN2000
Google play
Android

Advertisement

loading

Summary of Contents for Huawei SDongleA-03

  • Page 1 You can download this document by scanning the QR code. • SDongleA-03 Smart Dongle (the "Dongle" for short) is a smart communications expansion module that works with Huawei inverters to implement wireless communication between inverters and management systems through the 4G network.
  • Page 2 Modbus TCP protocol and configure the access point table based on the definitions of Huawei inverter interfaces. You need to set NMS server and NMS server port for inverters as required by a third-party management system and replace the client certificate.