  • Page 21 BATHROOM VENTILATOR  OPERATION MANUAL  HB21417  HB21424  Please read this Operation Manual carefully before using this machine.  Warning: In order to prevent damage or accident, this machine must be installed by those  qualified technicians recognized by the government. ...
  • Page 22 1. Important Safety Information  Must use the appropriate power (220V‐240V ~/50Hz).  This product is not suitable for the disabled, mental retarded or mental disorder, or those who are lack of experience and common sense (including children) unless they are under guidance.  Take care of your children and do not allow them to play with this machine.  In order to use this machine more properly, and reduce any danger caused by the incorrect operation, please pay attention to the following items. If the power wire is broken, please ask for the supplier  and manufacturer’s replacement. Make sure the power wire places on suitable location and will not block the road. WARNING: In order to avoid overheating, do not cover  the heater. The heater must not be located immediately below a  socket outlet. Do not use this heater in the surroundings of a bath, a  shower or a swimming pool. Product do not control room temperature, when there  is  no  responsible  person  close  by,  please  do  not  let those disabled stay alone in the narrow room and use the machine.
  • Page 23 attention to them.    When  the  machine  was  installed  and  placed  at  the  correct  working  location,  there  should  be  a  person responsible for safety guidance and assistance, and to ensure  the  safety  of  the  users  to  understand  the potential risk of this machine. Children who aged from 3 to 8 only can turn on/off this machine. Please do not let  the  children  aged  from  3  to  8  to  do  regulation, cleaning, ...
  • Page 24 the room on their own, unless constant supervision is  provided.  Turn off the product and remove plug until the  product stops working and cool down completely before clean the unit. Please do not pull out the power plug by pulling the  power cord. It may cause the power cord damage or electric shock. If there is abnormal smell or noise when uses the  product, please stop using and pull out the power cord immediately. Please don't put heavy unit onto the power cord or  fold the power cord. It may lead to electric shock. Please don't have the wind blow to the children  directly for a long time. It may influence the children's health. Please don't touch the plug by wet hands.  Please don't put the wood or metal stick into the air  inlet or outlet. It may lead to electric shock, or product damage. Do not use it on outdoor areas.  This appliance is for household use only.  Do not immerse the appliance or the electrical cord or  plug in liquids. Do not use the appliance for any purpose not expressly  specified in this manual. This appliance must be attended at all times when it is  switched on. Do not insert any objects into the heater.
  • Page 25 explosive objective, away from the heater.  Do not place the appliance close to children or pets.  Never let children operate this appliance. Close supervision is necessary when this is used near children. Do not touch hot surface when in use.  Do not share the same circuit receptacle with others  appliances, otherwise may have burn hazard. Do not use extension cord or exchangeable plug.  Unplug heater if it fails to operate properly and inform  customer service center. Dispose of packaging properly.  The heater only for personal use, not for heating any  liquids or other danger things. Persons (including children) with reduced physical,  sensory or mental capabilities, or any individual lacking experience and knowledge should be supervised or given instruction by a person responsible for their safety when they using this appliance. Unless being supervised, the above persons (included children) can't use this appliance. ‐ 4 ‐ ...
  • Page 26 ns    2. Instal lation Pr recaution  This p roduct sho ould be ins talled in th he place wh here can b ear the we eight of thi s goods.   Incorr rect installa ation may c cause nois e, empath y. Please a assembly p roperly.     In  ord der  not  to  cause  the   dew  flow wing  back  f from ...
  • Page 27 【Names of the device and functions】  Unit: mm  1. Machine Front Side Bottom Remote Control  1. Pre‐Filter, Carbon Filter 2. Front Panel 3. Display Panel 4. Air Outlet 5. Stainless Steel Housing 6. Metal Louver 7. Air Outlet Joint (Applicable to Window type installation) (Applicable to Ceiling/Wall type installation) ‐ 6 ‐ ...
  • Page 28 2. Remote LCD Display Battery Replacement sense Ionizer Time Display Air volume Hi/Mid/Lo Swing Function Display Remark: The remote control of HB21417 and HB21424 is the same except the model  number difference.      ‐ 7 ‐ ...
  • Page 29: Installation Method

    Over 5cm 【Installation Method】   Main Body Air outlet joint A. Ceiling fixed frame method  Exhaust pipe Downdip 1°-2° Over 50cm to the wall Self-tapping Inspection opening screw(2 pieces)  Installation reference picture: Front Panel Screw hole 1,2,3,4,5,6,7,8 for ceiling joist installation  Screw hole A,B,C,D for suspended ceiling installation  Screw hole 1,2,3,4,5,6,7,8 for window installation   Install the Fixed Frame to the ceiling  Make the fixed frame.  Please use materials that can bear 8.5kg to fix the surrounding part.  The fixed frame should use sticks of 30*25mm.  Size of the inner part of the frame: 380*272mm. ...
  • Page 30 【Instal lation M Method】   B. Ceilin ng Type M Method   Follo ow the belo ow diagram  to fix the m main body w with the M8 8 nut and th he suspende ers  (sug ggested to u use M8 susp penders and d need to be e purchased d separately y).    M8 Suspender M8 Nut Lock Washer Washer Lock Washer M8 Nut Ceiling suspension Bracket ...
  • Page 31: Air Exhaust

    【Installation Method】  C. Wall mount type method  1. Applicable to the bathroom without ceiling. 2. Firstly set the support stick transverse stability to the wall, then embed the main body on the support. 3. Set the exhaust pipe (4“ ( 100mm) ) to the glass window. Fix the exhaust pipe to the air outlet joint with tape or metal clamp. 4. Applicable size of the main body: 420x320mm *need to reserve 200 mm on the right side to install the exhaust pipe and air outlet joint. Thickness of the main body:216mm 5. The minimum distance between the surrounding structures should be 50cm。 200mm 【Air Exhaust】  Please avoid the following situations when installing the exhaust pipe.  1. Over bending. 2. Bending too much. 3. The bend of the pipe comes too close to the main body. 4. The bend shrinks. ‐ 10 ‐ ...
  • Page 32 【Installation Method】  Wall Window Type  Window Stainless Steel Housing  Size  Front Panel  Front Panel (HxW): 320x420 mm  Machine Body* (HxW): 270x372 mm  * Exclude the front panel Window  Window Cut Out (HxW): 275x377 mm  1. Install  at  the  place  of  the  aluminum  framed  window  or  replace  the  exhaust  fan  in  the bathroom.    2. Fix  the  stainless  steel  housing  to  the  frame  of  the  aluminum  window  (must  use  the waterproof glue for the waterproof). ...
  • Page 33 【Installation of the Remote Control】  1. Take out the remote control from the holder. 2. Install the remote control to suitable place. Check the main body can receive signal from the  remote  control  installation  location  or  take  out  the  remote  control  to  check  the receiver sensitivity. The installation location cannot be toward the direct spraying area of the shower. 3. Fix  the  remote  control  holder  to  the  designed  place  and  make  marks  according  to  the arrows. 4. Dig holes according to the mark, fill the holes with 2 plastic plugs, and fix the holder with screws.
  • Page 34 【Instructions】  Operation Mode  Time  Function  Application  Default  Setting  Ventilation Fan  Circulation Fan  PTC*  (Max.)  1. Quick Heat Off  High Speed    On  2 hrs  12 hrs    Heat (Hi)  Off  High Speed  2 hrs  12 hrs  On  Warm Air    Heat (Mid)  Off  Medium Speed  2 hrs  12 hrs  On    Heat (Lo)  Off  Low Speed  2 hrs  12 hrs  On ...
  • Page 35: Function Descriptions

    【Function Descriptions】  1) Display  :Power Indicator – Blue indicator light on when connected to power supply  :Air Quality Indicator – Red indicator light means “Poor”,    Orange indicator light  means “Fair”, Green indicator light means “Good”  :Malfunction Indicator – Red indicator light on when the machine is failure  2) HEAT Function – Quick Heat  Press the “Quick Heat” button, the LCD displays the “Quick Heat” icon, air volume will  run at “Hi “mode. Timer: the default time is 2 hrs. By pressing “Timer “up or down button to select time  duration. The time can be set from 5 mins to 12 hrs. The time counter will be displayed at  the  LCD.  The  time  selected  will  be  recorded  in  memory  when  it  is  off,  and  will resume in your next usage. Stop:  when  press  the  “Stop  “button  or  pre‐set  time  runs  over,  the  LCD  “Quick  Heat ...
  • Page 36 3)  VENT Function ‐ Hi / Mid / Lo  Press the “Vent” button, the LCD displays “Vent” icon, air volume will run at “Hi” mode.  Press the button again to select “Hi”, “Mid” or “Lo” mode. Timer: the default time is 2 hrs. By pressing “Timer” up or down button to select time  duration. The time can be set from 5 mins to 24 hrs. The time counter will be displayed on  the  LCD.  The  time  selected  will  be  recorded  in  memory  when  it  is  off,  and  will resume in your next usage. Under the mode, the inter‐change of the air volume between “Hi”, “Mid” or “Lo” will  not affect the time counting. Stop: when press the “Stop” button or the pre‐set time runs over, the LCD “Vent” and  the time display would disappear, and the machine will stop automatically. 4)  DRY Function ‐ Hi / Mid / Lo  Press  the  “Dry”  button,  the  LCD  displays  “Dry”  icon,  the  air  volume  will  run  at  “Hi” ...
  • Page 37 6)6  Sense De‐odor Function  Press “6  Sense” button, the LCD displays “ ” icon.  In  6   Sense  mode,  the  machine  will  automatically  detect  the  odor  of  the  bathroom  and  run  the  de‐odor  function.  The  air  quality  light  will  indicate  the  odor  level,  Red indicator light means “Poor”, the machine will run at “Hi” mode; Orange indicator light means  “Fair”,  and  the  machine  will  run  at  “Mid”  mode;  Green  indicator  light  means “Good”, and the machine will run at “Lo” mode.
  • Page 38 Swing Function – Manual (Left / Right)  Left and right louver function to provide selection of wide airflow distribution of up to  120 degree, or concentrated airflow. Diffused Airflow Concentrated Airflow  Ionizer Function  When  the  circulation  fan  motor  is  running,  press  the  “Ionizer”  button,  the  LCD  will  display “ ” icon. Ionizer function is not valid under the modes of “Vent”, 24H Vent”, “Delay Vent” and “6  Sense”. Stop: when Ionizer is running, press the “Ionizer” button, Ionizer will stop, and the LCD  “ ” icon would disappear. Press the “Ionizer” button again, Ionizer will turn on again and the LCD will display “ ” icon as well. ‐ 17 ‐ ...
  • Page 39 【Maintenance and Safety Items】   Maintenance and cleaning: ● Please do turn off the power before maintenance work. Front Panel  1. Front panel cleaning: Filter ○ Please use the soft rag to clean the dirty place of the front panel. ○ Put a clean rag in the warm water dissolved with neutral detergent, and then use the  rag  to  wipe  the  front  panel.  Use  another  rag  to  wipe  the  cover.  The  surface shall have no detergent residues. 2. Filter Cleaning: A. Pre‐Filter ○ Use  a  rechargeable  handheld  vacuum  cleaner  to  remove  dust  from  the  filter  or wash ...
  • Page 40  Safety Items:  Do  not  put  your  hands  into  the  machine  when  running,  to  avoid  from  injury  or burn by the heater.  Do  not  spray  water  into  the  main  body,  which  may  damage  the  motor,  or  cause electric shock by the electricity leakage.  In order to avoid from any accident or injury, if any of the following symptoms and abnormal  situation  occur,  please  switch  off  the  electricity  and  ask  qualified electrical engineering contractor for repair or check. (Self repair by user is strictly prohibited to avoid danger).
  • Page 41: Product Specification

    Fix the suspension  Lock washer  Φ   8  bracket  Ceiling  suspension  ‐  4  bracket  Applicable to  5. Air Outlet Joint Ceiling/Wall type  ‐  ‐  1  installation  【Product Specification】  Model No.  HB21417  HB21424    Voltage (V)  220‐240V~ Frequency (Hz)    50Hz Power (W)  1700W  2450W  Product Size  320 x 420 x 216  (H x W x D) mm  Product Size (excl. panel)  270 x 372  (H x W) mm  Net Weight (kg)  8.5 ...